These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 9641622)

  • 1. Histomorphometrical and mechanical evaluation of titanium plasma-spray-coated implants placed in the cortical bone of goats.
    Vercaigne S; Wolke JG; Naert I; Jansen JA
    J Biomed Mater Res; 1998 Jul; 41(1):41-8. PubMed ID: 9641622
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of titanium plasma-sprayed implants on trabecular bone healing in the goat.
    Vercaigne S; Wolke JG; Naert I; Jansen JA
    Biomaterials; 1998 Jun; 19(11-12):1093-9. PubMed ID: 9692808
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hydroxyapatite-coating on titanium arc sprayed titanium implants.
    Nakashima Y; Hayashi K; Inadome T; Uenoyama K; Hara T; Kanemaru T; Sugioka Y; Noda I
    J Biomed Mater Res; 1997 Jun; 35(3):287-98. PubMed ID: 9138063
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bone healing capacity of titanium plasma-sprayed and hydroxylapatite-coated oral implants.
    Vercaigne S; Wolke JG; Naert I; Jansen JA
    Clin Oral Implants Res; 1998 Aug; 9(4):261-71. PubMed ID: 9760901
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bone-supportive behavior of microplasma-sprayed CaP-coated implants: mechanical and histological outcome in the goat.
    Junker R; Manders PJ; Wolke J; Borisov Y; Jansen JA
    Clin Oral Implants Res; 2010 Feb; 21(2):189-200. PubMed ID: 19958376
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A histological evaluation of TiO2-gritblasted and Ca-P magnetron sputter coated implants placed into the trabecular bone of the goat: Part 2.
    Vercaigne S; Wolke JG; Naert I; Jansen JA
    Clin Oral Implants Res; 2000 Aug; 11(4):314-24. PubMed ID: 11168224
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical and histologic evaluation of Ca-P plasma-spray and magnetron sputter-coated implants in trabecular bone of the goat.
    Hulshoff JE; Hayakawa T; van Dijk K; Leijdekkers-Govers AF; van der Waerden JP; Jansen JA
    J Biomed Mater Res; 1997 Jul; 36(1):75-83. PubMed ID: 9212391
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of different surface modifications for titanium implants installed into the goat iliac crest.
    van Oirschot BA; Meijer GJ; Bronkhorst EM; Närhi T; Jansen JA; van den Beucken JJ
    Clin Oral Implants Res; 2016 Feb; 27(2):e57-67. PubMed ID: 25486997
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bone response adjacent to calcium phosphate electrostatic spray deposition coated implants: an experimental study in goats.
    Manders PJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2006 Oct; 17(5):548-53. PubMed ID: 16958695
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A histological and histomorphometrical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma-sprayed coatings in goats.
    Dhert WJ; Klein CP; Jansen JA; van der Velde EA; Vriesde RC; Rozing PM; de Groot K
    J Biomed Mater Res; 1993 Jan; 27(1):127-38. PubMed ID: 8380595
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical and histological evaluation of amorphous calcium phosphate and poorly crystallized hydroxyapatite coatings on titanium implants.
    Maxian SH; Zawadsky JP; Dunn MG
    J Biomed Mater Res; 1993 Jun; 27(6):717-28. PubMed ID: 8408101
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bone-bonding behavior of plasma-sprayed coatings of BioglassR, AW-glass ceramic, and tricalcium phosphate on titanium alloy.
    Kitsugi T; Nakamura T; Oka M; Senaha Y; Goto T; Shibuya T
    J Biomed Mater Res; 1996 Feb; 30(2):261-9. PubMed ID: 9019492
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of plasma-spray and magnetron-sputter Ca-P-coated implants: an in vivo experiment using rabbits.
    Hulshoff JE; van Dijk K; van der Waerden JP; Wolke JG; Kalk W; Jansen JA
    J Biomed Mater Res; 1996 Jul; 31(3):329-37. PubMed ID: 8806058
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vivo behavior and mechanical stability of surface-modified titanium implants by plasma spray coating and chemical treatments.
    Lee BH; Kim JK; Kim YD; Choi K; Lee KH
    J Biomed Mater Res A; 2004 May; 69(2):279-85. PubMed ID: 15058000
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The removal of Al2O3 particles from grit-blasted titanium implant surfaces: effects on biocompatibility, osseointegration and interface strength in vivo.
    Rüger M; Gensior TJ; Herren C; von Walter M; Ocklenburg C; Marx R; Erli HJ
    Acta Biomater; 2010 Jul; 6(7):2852-61. PubMed ID: 20080212
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.
    Buser D; Schenk RK; Steinemann S; Fiorellini JP; Fox CH; Stich H
    J Biomed Mater Res; 1991 Jul; 25(7):889-902. PubMed ID: 1918105
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detachment of titanium and fluorohydroxyapatite particles in unloaded endosseous implants.
    Martini D; Fini M; Franchi M; Pasquale VD; Bacchelli B; Gamberini M; Tinti A; Taddei P; Giavaresi G; Ottani V; Raspanti M; Guizzardi S; Ruggeri A
    Biomaterials; 2003 Mar; 24(7):1309-16. PubMed ID: 12527273
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo behaviour of hydroxyapatite coatings on titanium implants: a quantitative study in the rabbit.
    Darimont GL; Cloots R; Heinen E; Seidel L; Legrand R
    Biomaterials; 2002 Jun; 23(12):2569-75. PubMed ID: 12033605
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of Ca-P plasma-sprayed coatings on the initial bone healing of oral implants: an experimental study in the goat.
    Caulier H; Vercaigne S; Naert I; van der Waerden JP; Wolke JG; Kalk W; Jansen JA
    J Biomed Mater Res; 1997 Jan; 34(1):121-8. PubMed ID: 8978661
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Trabecular bone response to surface roughened and calcium phosphate (Ca-P) coated titanium implants.
    Hayakawa T; Yoshinari M; Kiba H; Yamamoto H; Nemoto K; Jansen JA
    Biomaterials; 2002 Feb; 23(4):1025-31. PubMed ID: 11791905
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.