These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 9643124)

  • 1. [HIV diagnosis 1998].
    Erb P; Matter L
    Ther Umsch; 1998 May; 55(5):279-84. PubMed ID: 9643124
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of HIV-1 p24 antigen by signal-amplification-boosted ELISA of heat-denatured plasma is a simple and inexpensive alternative to tests for viral RNA.
    Schüpbach J
    AIDS Rev; 2002; 4(2):83-92. PubMed ID: 12152521
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Early diagnosis of primary HIV infections: using a combined screening test (p24 antigen and anti-HIV antibodies)].
    Yerly S; Simon F; Perrin L
    Schweiz Med Wochenschr; 1999 Feb; 129(8):319-22. PubMed ID: 10189669
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Screening of HIV infection: role of molecular and immunological assays.
    Weber B
    Expert Rev Mol Diagn; 2006 May; 6(3):399-411. PubMed ID: 16706742
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Predictive value of two commercial human immunodeficiency virus serological tests in cases with indeterminate Western blot results.
    Huang LJ; Liu CY; Chu SC; Wong WW; Lin YC; Liu WT; Chan YJ
    J Microbiol Immunol Infect; 2006 Jun; 39(3):219-24. PubMed ID: 16783452
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Molecular biological assessment methods and understanding the course of the HIV infection.
    Katzenstein TL
    APMIS Suppl; 2003; (114):1-37. PubMed ID: 14626050
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combination assay detecting both human immunodeficiency virus (HIV) p24 antigen and anti-HIV antibodies opens a second diagnostic window.
    Speers D; Phillips P; Dyer J
    J Clin Microbiol; 2005 Oct; 43(10):5397-9. PubMed ID: 16208030
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Diagnosis and virologic monitoring of HIV infection].
    Rouzioux C; Chaix ML
    Rev Prat; 1999 Oct; 49(16):1747-9. PubMed ID: 10578604
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analytical and clinical sensitivity of the Procleix Ultrio HIV-1/HCV/HBV assay in samples with a low viral load.
    Katsoulidou A; Moschidis Z; Sypsa V; Chini M; Papatheodoridis GV; Tassopoulos NC; Mimidis K; Karafoulidou A; Hatzakis A
    Vox Sang; 2007 Jan; 92(1):8-14. PubMed ID: 17181585
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Laboratory diagnosis in HIV infection].
    Matter L
    Schweiz Med Wochenschr; 1991 Aug; 121(34):1183-6. PubMed ID: 1925446
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multicenter evaluation of a new 4th generation HIV screening assay Elecsys HIV combi.
    Weber B; Orazi B; Raineri A; Thorstensson R; Bürgisser P; Mühlbacher A; Areal C; Eiras A; Villaescusa R; Camacho R; Diogo I; Roth HJ; Zahn I; Bartel J; Bossi V; Piro F; Atamasirikul K; Permpikul P; Webber L; Singh S
    Clin Lab; 2006; 52(9-10):463-73. PubMed ID: 17078473
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laboratory diagnosis of HIV infection in Papua New Guinea.
    Babona DV; Slama G; Puiahi E
    P N G Med J; 1996 Sep; 39(3):200-4. PubMed ID: 9795563
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Screening of HIV in blood banks. Evaluation of fourth generation kits].
    Canna F; Treviño E; Domínguez C; Gastaldello R; Barbas G; Cudola A; Irizar M; Bepre H; Gallego S
    Medicina (B Aires); 2003; 63(6):685-91. PubMed ID: 14719309
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays.
    Kwon JA; Yoon SY; Lee CK; Lim CS; Lee KN; Sung HJ; Brennan CA; Devare SG
    J Virol Methods; 2006 Apr; 133(1):20-6. PubMed ID: 16313975
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of three automated fourth-generation combined HIV antigen/antibody assays in large-scale screening of blood donors and clinical samples.
    Malm K; von Sydow M; Andersson S
    Transfus Med; 2009 Apr; 19(2):78-88. PubMed ID: 19320855
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrasensitive quantitative HIV-1 p24 antigen assay adapted to dried plasma spots to improve treatment monitoring in low-resource settings.
    Knuchel MC; Tomasik Z; Speck RF; Lüthy R; Schüpbach J
    J Clin Virol; 2006 May; 36(1):64-7. PubMed ID: 16431154
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The measurement of HIV-1 viral load in resource-limited settings: how and where?
    Rouet F; Rouzioux C
    Clin Lab; 2007; 53(3-4):135-48. PubMed ID: 17447649
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Current state of HIV/AIDS in Taiwan and reappraisal of early diagnostic value of serial and comparative analyses of western blot patterns of HIV infection.
    Chen MY; Chuang CY
    Gan To Kagaku Ryoho; 2002 Feb; 29 Suppl 1():39-46. PubMed ID: 11890112
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance evaluation of the new fully automated human immunodeficiency virus antigen-antibody combination assay designed for blood screening.
    Sickinger E; Jonas G; Yem AW; Goller A; Stieler M; Brennan C; Hausmann M; Schochetman G; Devare SG; Hunt JC; Kapprell HP; Bryant JD
    Transfusion; 2008 Apr; 48(4):584-93. PubMed ID: 18194389
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Could the new HIV combined p24 antigen and antibody assays replace p24 antigen specific assays?
    Ly TD; Ebel A; Faucher V; Fihman V; Laperche S
    J Virol Methods; 2007 Jul; 143(1):86-94. PubMed ID: 17395277
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.