164 related articles for article (PubMed ID: 9645780)
1. Rapid arterial anastomosis with titanium clips.
Pikoulis E; Burris D; Rhee P; Nishibe T; Leppäniemi A; Wherry D; Rich N
Am J Surg; 1998 Jun; 175(6):494-6. PubMed ID: 9645780
[TBL] [Abstract][Full Text] [Related]
2. Arterial reconstruction with vascular clips is safe and quicker than sutured repair.
Pikoulis E; Rhee P; Nishibe T; Leppäniemi AK; Fishback N; Hufnagel HV; Wherry DC; Rich NM
Cardiovasc Surg; 1998 Dec; 6(6):573-8. PubMed ID: 10395258
[TBL] [Abstract][Full Text] [Related]
3. Arterial and venous repair with vascular clips: comparison with suture closure.
Leppäniemi A; Wherry D; Pikoulis E; Hufnagel H; Waasdorp C; Fishback N; Rich N
J Vasc Surg; 1997 Jul; 26(1):24-8. PubMed ID: 9240317
[TBL] [Abstract][Full Text] [Related]
4. Arterial repair with synthetic patch by using titanium clips.
Pikoulis E; Rhee P; Nishibe T; Burris D; Leppäniemi AK; Fishback N; Wherry DC; Rich NM
J Trauma; 2000 Feb; 48(2):292-5. PubMed ID: 10697089
[TBL] [Abstract][Full Text] [Related]
5. Vascular closure stapler clip anastomosis decreases aortic cross-clamping time compared to interrupted nonabsorbable and running absorbable sutures in growing pigs.
Calles-Vázquez MC; Viguera FJ; Crisóstomo V; Usón-Gargallo J
Ann Vasc Surg; 2006 Jan; 20(1):35-41. PubMed ID: 16378146
[TBL] [Abstract][Full Text] [Related]
6. Growing cava vein anastomosis: comparison of cross-clamping and suture times using VCS metallic clips, interrupted nonabsorbable, or continuous absorbable suturing techniques.
Calles-Vázquez MC; Abellán Rubio E; Ayala VC; Usón Gargallo J; Sánchez Margallo FM
Ann Vasc Surg; 2013 Oct; 27(7):947-53. PubMed ID: 23993110
[TBL] [Abstract][Full Text] [Related]
7. Vascular closure system type of nonpenetrating arcuate-legged titanium clips for graft-artery and graft-graft anastomoses: review of our clinical experience.
Inoue Y; Kubota T; Jibiki M; Hirokawa M; Sugano N; Iwai T
Surg Today; 2004; 34(3):231-6. PubMed ID: 14999535
[TBL] [Abstract][Full Text] [Related]
8. A comparison of para-anastomotic compliance profiles after vascular anastomosis: nonpenetrating clips versus standard sutures.
Baguneid MS; Goldner S; Fulford PE; Hamilton G; Walker MG; Seifalian AM
J Vasc Surg; 2001 Apr; 33(4):812-20. PubMed ID: 11296337
[TBL] [Abstract][Full Text] [Related]
9. Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy.
Pikoulis E; Koronarchis D; Filis K; Leppäniemi A; Papas S; Xiromeritis N; Papalambros E; Bastounis E
Surg Endosc; 2001 Jul; 15(7):726-8. PubMed ID: 11591977
[TBL] [Abstract][Full Text] [Related]
10. Vein patch angioplasty with non-penetrating titanium clips. Comparison to standard suture technique.
Pikoulis E; Rhee P; Nishibe T; Koronarchis D; Leppäniemi A; Karavokyros I; Burris D; Bakoyiannis C; Fishback N; Wherry D; Rich N
Acta Chir Belg; 2009; 109(6):756-9. PubMed ID: 20184062
[TBL] [Abstract][Full Text] [Related]
11. Heterotopic renal transplantation in piglets using vascular closure stapler metallic clips or conventional suturing techniques: comparison of vessel growth and macroscopical study.
Calles-Vázquez MC; Rubio EA; Ayala VC; Gargallo JU; Margallo FM
J Pediatr Surg; 2012 Jul; 47(7):1390-8. PubMed ID: 22813802
[TBL] [Abstract][Full Text] [Related]
12. Five years' world experience with nonpenetrating clips for vascular anastomoses.
Zeebregts CJ; Kirsch WM; van den Dungen JJ; Zhu YH; van Schilfgaarde R
Am J Surg; 2004 Jun; 187(6):751-60. PubMed ID: 15191871
[TBL] [Abstract][Full Text] [Related]
13. [VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat].
Gerbault O; Arrouvel C; Servant JM; Revol M; Banzet P
Ann Chir Plast Esthet; 1998 Feb; 43(1):27-39. PubMed ID: 9768090
[TBL] [Abstract][Full Text] [Related]
14. Clinical experience with non-penetrating vascular clips in free-flap reconstructions.
Zeebregts C; Acosta R; Bölander L; van Schilfgaarde R; Jakobsson O
Br J Plast Surg; 2002 Mar; 55(2):105-10. PubMed ID: 11987941
[TBL] [Abstract][Full Text] [Related]
15. Ureteral repair with titanium staples: comparison with suture closure.
Leppäniemi AK; Wherry DC; Pikoulis E; Hufnagel HV; Fishback N; Rich NM
Urology; 1998 Apr; 51(4):553-7. PubMed ID: 9586606
[TBL] [Abstract][Full Text] [Related]
16. Angiographic, ultrasonographic, and macroscopic assessment of aortic growth after VCS clips, interrupted polypropylene, or running polyglycolic acid anastomosis.
Calles-Vázquez MC; Crisóstomo V; Sun F; Usón-Gargallo J
J Pediatr Surg; 2007 Oct; 42(10):1695-702. PubMed ID: 17923198
[TBL] [Abstract][Full Text] [Related]
17. Comparison of arcuate-legged clipped versus sutured hepatic artery, portal vein, and bile duct anastomoses.
Geevarghese SK; Bradley AL; Atkinson J; Wright JK; Chapman WC; Van Buren DH; Blair KT; Hutchins CH; Jabbour K; Phillips J; Williams PE; Pinson CW
Am Surg; 1999 Apr; 65(4):311-6. PubMed ID: 10190352
[TBL] [Abstract][Full Text] [Related]
18. Vein and artery growth after anastomosis with vascular closure staple clips vs interrupted polypropylene suture: application in pediatric vascular surgery.
Calles-Vázquez Mdel C; Viguera FJ; Sun F; Usón JM; Usón J
J Pediatr Surg; 2005 Sep; 40(9):1428-35. PubMed ID: 16150344
[TBL] [Abstract][Full Text] [Related]
19. [Biliary endo-to-end anastomosis with extramucosal titanium clips. Initial results of a new technique].
Birth M; Gerberding J; Markert U; Wohlschläger C; Brugmans F; Bruch HP
Zentralbl Chir; 2000; 125(12):990-6. PubMed ID: 11190620
[TBL] [Abstract][Full Text] [Related]
20. Use of the vascular closure staple clip applier for microvascular anastomosis in free-flap surgery.
Cope C; Lee K; Stern H; Pennington D
Plast Reconstr Surg; 2000 Jul; 106(1):107-10. PubMed ID: 10883621
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]