These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
243 related articles for article (PubMed ID: 9652314)
1. Prognostic value of 1-day stress/rest electrocardiogram-gated single-photon emission computed tomography using Tc-99m-labeled methoxy-isobutyl isonitrile. Sugihara H; Tamaki N; Mitsunami K; Kinoshita M Jpn Circ J; 1998 Jun; 62(6):405-8. PubMed ID: 9652314 [TBL] [Abstract][Full Text] [Related]
2. [Value of stress-rest ECG gated SPECT one day protocol using 99mTc-MIBI]. Nozawa M; Tamaki N; Sugihara H; Inamoto Y; Taniguchi Y; Aoki E; Furuichi K; Mitsunami K; Kinoshita M Kaku Igaku; 1995 Dec; 32(12):1363-8. PubMed ID: 8587219 [TBL] [Abstract][Full Text] [Related]
3. Gated Tc-99m sestamibi SPECT versus stress-rest SPECT in detecting coronary artery disease: correlation with coronary angiography in patients without myocardial infarction. Guerra UP; Giacomuzzi F; Di Gregorio F; Bax JJ; Slavich GA; Fioretti PM Clin Nucl Med; 1999 Dec; 24(12):921-6. PubMed ID: 10595468 [TBL] [Abstract][Full Text] [Related]
4. Combined analysis of resting regional wall thickening and stress perfusion with electrocardiographic-gated technetium 99m-labeled sestamibi single-photon emission computed tomography: prediction of stress defect reversibility. Snapper HJ; Shea NL; Konstam MA; Oates E; Udelson JE J Nucl Cardiol; 1997; 4(1 Pt 1):3-10. PubMed ID: 9138837 [TBL] [Abstract][Full Text] [Related]
5. Usefulness of stress gated technetium-99m single photon emission computed tomographic myocardial perfusion imaging for the prediction of cardiac death in patients with moderate to severe left ventricular systolic dysfunction and suspected coronary artery disease. Ahlberg AW; Kazi FA; Azemi T; Katten DM; O'Sullivan DM; Papaioannou GI; Danias PG; Heller GV Am J Cardiol; 2012 Jan; 109(1):26-30. PubMed ID: 21943938 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of myocardial perfusion and function by gated SPECT in patients with Behçet's disease. Kaya E; Saglam H; Ciftci I; Kulac M; Karaca S; Melek M Ann Nucl Med; 2008 May; 22(4):287-95. PubMed ID: 18535879 [TBL] [Abstract][Full Text] [Related]
7. Simultaneous assessment of left ventricular wall motion and myocardial perfusion with technetium-99m-methoxy isobutyl isonitrile at stress and rest in patients with angina: comparison with thallium-201 SPECT. Villanueva-Meyer J; Mena I; Narahara KA J Nucl Med; 1990 Apr; 31(4):457-63. PubMed ID: 2324821 [TBL] [Abstract][Full Text] [Related]
8. Comparative study of single-injection, single-acquisition 99mTc-MIBI gated SPET and stress-rest perfusion SPET for the evaluation of myocardial viability after bypass surgery in coronary artery disease. Yoon SN; Lee DS; Chung JK; Lee MC Eur J Nucl Med; 2000 Dec; 27(12):1747-53. PubMed ID: 11189935 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of cardiac function in myocardial infarction patients by ECG 99mTc-MIBI gated SPECT using a three-dimensional perfusion/motion map procedure. Nomura M; Nakaya Y; Nada T; Miyajima H; Kondo Y; Saito K; Ito S Jpn Heart J; 1999 Jul; 40(4):413-25. PubMed ID: 10611906 [TBL] [Abstract][Full Text] [Related]
10. Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion, postexercise regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy. Chua T; Kiat H; Germano G; Maurer G; van Train K; Friedman J; Berman D J Am Coll Cardiol; 1994 Apr; 23(5):1107-14. PubMed ID: 8144776 [TBL] [Abstract][Full Text] [Related]
11. Simultaneous assessment of left ventricular wall motion and myocardial perfusion at rest and during exercise by technetium-99m methoxy isobutyl isonitrile. Takeishi Y; Tono-oka I; Chiba J; Abe S; Tsuiki K; Tomoike H; Yasui S Jpn Circ J; 1991 Dec; 55(12):1192-9. PubMed ID: 1837319 [TBL] [Abstract][Full Text] [Related]
12. The prognostic value of ECG-gated SPECT imaging in patients undergoing stress Tc-99m sestamibi myocardial perfusion imaging. Travin MI; Heller GV; Johnson LL; Katten D; Ahlberg AW; Isasi CR; Kaplan RC; Taub CC; Demus D J Nucl Cardiol; 2004; 11(3):253-62. PubMed ID: 15173772 [TBL] [Abstract][Full Text] [Related]
13. [Simultaneous assessment of myocardial perfusion and ventricular function using thallium-201 at rest/Tc-99m tetrofosmin at effort with single-photon emission computerized tomography, synchronized with electrocardiogram (synchronized SPECT). Initial experience in Latin America]. Puente A; Alexánderson E; Arroyo A; Lorenzo A; Victoria D Arch Inst Cardiol Mex; 2000; 70(5):448-55. PubMed ID: 11534095 [TBL] [Abstract][Full Text] [Related]
14. 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. Manrique A; Faraggi M; Véra P; Vilain D; Lebtahi R; Cribier A; Le Guludec D J Nucl Med; 1999 May; 40(5):805-9. PubMed ID: 10319754 [TBL] [Abstract][Full Text] [Related]
15. Serial assessment of left ventricular function during dobutamine stress by means of electrocardiography-gated myocardial SPECT: combination with dual-isotope myocardial perfusion SPECT for detection of ischemic heart disease. Kumita S; Cho K; Nakajo H; Toba M; Kijima T; Mizumura S; Oshina T; Kumazaki T; Sano J; Sakurai K; Munakata K J Nucl Cardiol; 2001; 8(2):152-7. PubMed ID: 11295692 [TBL] [Abstract][Full Text] [Related]
16. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. Berman DS; Hachamovitch R; Kiat H; Cohen I; Cabico JA; Wang FP; Friedman JD; Germano G; Van Train K; Diamond GA J Am Coll Cardiol; 1995 Sep; 26(3):639-47. PubMed ID: 7642853 [TBL] [Abstract][Full Text] [Related]
17. Site of myocardial infarction and severity of perfusion abnormalities impact on post-stress left ventricular function in patients with single-vessel disease: gated single-photon emission computed tomography methoxyisobutylisonitrile study. Sobic-Saranovic DP; Pavlovic SV; Beleslin BD; Petrasinovic ZR; Kozarevic NDj; Todorovic-Tirnanic MV; Ille TM; Jaksic ED; Artiko VM; Obradovic VB Nucl Med Commun; 2009 Feb; 30(2):148-54. PubMed ID: 19077915 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of post-stress left ventricular dysfunction and its relationship with perfusion abnormalities using gated SPECT in patients with cardiac syndrome X. Demir H; Kahraman G; Isgoren S; Tan YZ; Kilic T; Berk F Nucl Med Commun; 2008 Mar; 29(3):208-14. PubMed ID: 18349790 [TBL] [Abstract][Full Text] [Related]
19. Transient prolonged stunning induced by dipyridamole and shown on 1- and 24-hour poststress 99mTc-MIBI gated SPECT. Lee DS; Yeo JS; Chung JK; Lee MM; Lee MC J Nucl Med; 2000 Jan; 41(1):27-35. PubMed ID: 10647602 [TBL] [Abstract][Full Text] [Related]
20. Risk stratification with electrocardiographic-gated dobutamine stress technetium-99m sestamibi single-photon emission tomographic imaging: value of heart rate response and assessment of left ventricular function. Navare SM; Katten D; Johnson LL; Mather JF; Fowler MS; Ahlberg AW; Miele N; Heller GV J Am Coll Cardiol; 2006 Feb; 47(4):781-8. PubMed ID: 16487845 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]