These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 9652865)
21. A quantitative three-dimensional dose attenuation analysis around Fletcher-Suit-Delclos due to stainless steel tube for high-dose-rate brachytherapy by Monte Carlo calculations. Parsai EI; Zhang Z; Feldmeier JJ Brachytherapy; 2009; 8(3):318-23. PubMed ID: 19217355 [TBL] [Abstract][Full Text] [Related]
22. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition. Landry G; Reniers B; Murrer L; Lutgens L; Gurp EB; Pignol JP; Keller B; Beaulieu L; Verhaegen F Med Phys; 2010 Oct; 37(10):5188-98. PubMed ID: 21089752 [TBL] [Abstract][Full Text] [Related]
23. Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources. Melhus CS; Rivard MJ Med Phys; 2006 Jun; 33(6):1729-37. PubMed ID: 16872080 [TBL] [Abstract][Full Text] [Related]
24. TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source. Meigooni AS; Wright C; Koona RA; Awan SB; Granero D; Perez-Calatayud J; Ballester F Med Phys; 2009 Oct; 36(10):4711-9. PubMed ID: 19928102 [TBL] [Abstract][Full Text] [Related]
25. Dose calibrator response to brachytherapy sources: A Monte Carlo and analytic evaluation. Williamson JF; Morin RL; Khan FM Med Phys; 1983; 10(2):135-40. PubMed ID: 6865853 [TBL] [Abstract][Full Text] [Related]
26. Monte Carlo calculation of dose rate distributions around 192Ir wires. Ballester F; Hernández C; Pérez-Calatayud J; Lliso F Med Phys; 1997 Aug; 24(8):1221-8. PubMed ID: 9284243 [TBL] [Abstract][Full Text] [Related]
27. Design of an Yb-169 source optimized for gold nanoparticle-aided radiation therapy. Reynoso FJ; Manohar N; Krishnan S; Cho SH Med Phys; 2014 Oct; 41(10):101709. PubMed ID: 25281948 [TBL] [Abstract][Full Text] [Related]
28. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources. Bannon EA; Yang Y; Rivard MJ Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369 [TBL] [Abstract][Full Text] [Related]
29. Validation of GPUMCD for low-energy brachytherapy seed dosimetry. Hissoiny S; Ozell B; Després P; Carrier JF Med Phys; 2011 Jul; 38(7):4101-7. PubMed ID: 21859010 [TBL] [Abstract][Full Text] [Related]
30. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE. Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828 [TBL] [Abstract][Full Text] [Related]
31. Modeling a hypothetical 170Tm source for brachytherapy applications. Enger SA; D'Amours M; Beaulieu L Med Phys; 2011 Oct; 38(10):5307-10. PubMed ID: 21992348 [TBL] [Abstract][Full Text] [Related]
32. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source. Daskalov GM; Löffler E; Williamson JF Med Phys; 1998 Nov; 25(11):2200-8. PubMed ID: 9829246 [TBL] [Abstract][Full Text] [Related]
33. Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192Ir sources. Williamson JF; Li Z Med Phys; 1995 Jun; 22(6):809-19. PubMed ID: 7565372 [TBL] [Abstract][Full Text] [Related]
34. Technical note: Monte Carlo derivation of TG-43 dosimetric parameters for radiation therapy resources and 3M Cs-137 sources. Pérez-Calatayud J; Granero D; Ballester F; Casal E; Cases R; Agramunt S Med Phys; 2005 Aug; 32(8):2464-70. PubMed ID: 16193775 [TBL] [Abstract][Full Text] [Related]
35. Impact of the differential fluence distribution of brachytherapy sources on the spectroscopic dose-rate constant. Malin MJ; Bartol LJ; DeWerd LA Med Phys; 2015 May; 42(5):2379-88. PubMed ID: 25979033 [TBL] [Abstract][Full Text] [Related]
36. Attenuation of intracavitary applicators in 192Ir-HDR brachytherapy. Ye SJ; Brezovich IA; Shen S; Duan J; Popple RA; Pareek PN Med Phys; 2004 Jul; 31(7):2097-106. PubMed ID: 15305463 [TBL] [Abstract][Full Text] [Related]
37. Radial dose distribution of 192Ir and 137Cs seed sources. Thomason C; Higgins P Med Phys; 1989; 16(2):254-7. PubMed ID: 2716705 [TBL] [Abstract][Full Text] [Related]
38. Study of encapsulated 170Tm sources for their potential use in brachytherapy. Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484 [TBL] [Abstract][Full Text] [Related]
39. Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicator. Gifford KA; Mourtada F; Cho SH; Lawyer A; Horton JL Radiother Oncol; 2005 Nov; 77(2):210-5. PubMed ID: 16216363 [TBL] [Abstract][Full Text] [Related]
40. Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effects. Pérez-Calatayud J; Granero D; Ballester F; Puchades V; Casal E Med Phys; 2004 Mar; 31(3):493-9. PubMed ID: 15070245 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]