These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 9653854)

  • 1. Do multiple measurements employing different ultrasonic techniques improve the accuracy of amniotic fluid volume assessment?
    Magann EF; Chauhan SP; Whitworth NS; Klausen JH; Saltzman AK; Morrison JC
    Aust N Z J Obstet Gynaecol; 1998 May; 38(2):172-5. PubMed ID: 9653854
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasonographic assessment of amniotic fluid does not reflect actual amniotic fluid volume.
    Chauhan SP; Magann EF; Morrison JC; Whitworth NS; Hendrix NW; Devoe LD
    Am J Obstet Gynecol; 1997 Aug; 177(2):291-6; discussion 296-7. PubMed ID: 9290442
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of ultrasonography in evaluating amniotic fluid volume at less than 24 weeks' gestation.
    Magann EF; Whitworth NS; Klausen JH; Perry KG; Martin JN; Morrison JC
    J Ultrasound Med; 1995 Dec; 14(12):895-7. PubMed ID: 8583524
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Amniotic fluid index and single deepest pocket: weak indicators of abnormal amniotic volumes.
    Magann EF; Chauhan SP; Barrilleaux PS; Whitworth NS; Martin JN
    Obstet Gynecol; 2000 Nov; 96(5 Pt 1):737-40. PubMed ID: 11042310
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The accuracy of ultrasound evaluation of amniotic fluid volume in singleton pregnancies: the effect of operator experience and ultrasound interpretative technique.
    Magann EF; Perry KG; Chauhan SP; Anfanger PJ; Whitworth NS; Morrison JC
    J Clin Ultrasound; 1997 Jun; 25(5):249-53. PubMed ID: 9314106
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of amniotic fluid volume: accuracy of ultrasonography techniques.
    Magann EF; Nolan TE; Hess LW; Martin RW; Whitworth NS; Morrison JC
    Am J Obstet Gynecol; 1992 Dec; 167(6):1533-7. PubMed ID: 1471660
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Toward consistent terminology: assessment and reporting of amniotic fluid volume.
    Moise KJ
    Semin Perinatol; 2013 Oct; 37(5):370-4. PubMed ID: 24176162
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasound estimation of amniotic fluid volume using the largest vertical pocket containing umbilical cord: measure to or through the cord?
    Magann EF; Chauhan SP; Washington W; Whitworth NS; Martin JN; Morrison JC
    Ultrasound Obstet Gynecol; 2002 Nov; 20(5):464-7. PubMed ID: 12423483
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of the Ultrasound Estimate of the Amniotic Fluid Volume (Amniotic Fluid Index and Single Deepest Pocket) to Identify Actual Low, Normal, and High Amniotic Fluid Volumes as Determined by Quantile Regression.
    Hughes DS; Magann EF; Whittington JR; Wendel MP; Sandlin AT; Ounpraseuth ST
    J Ultrasound Med; 2020 Feb; 39(2):373-378. PubMed ID: 31423632
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative efficacy of two sonographic measurements for the detection of aberrations in the amniotic fluid volume and the effect of amniotic fluid volume on pregnancy outcome.
    Magann EF; Morton ML; Nolan TE; Martin JN; Whitworth NS; Morrison JC
    Obstet Gynecol; 1994 Jun; 83(6):959-62. PubMed ID: 8190440
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasonic assessment of the amniotic fluid volume in diamniotic twins.
    Magann EF; Chauhan SP; Martin JN; Whitworth NS; Morrison JC
    J Soc Gynecol Investig; 1995; 2(4):609-13. PubMed ID: 9420865
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Amniotic fluid assessment.
    Williams K
    Obstet Gynecol Surv; 1993 Dec; 48(12):795-800. PubMed ID: 8309662
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dye-dilution techniques using aminohippurate sodium: do they accurately reflect amniotic fluid volume?
    Magann EF; Whitworth NS; Files JC; Terrone DA; Chauhan SP; Morrison JC
    J Matern Fetal Neonatal Med; 2002 Mar; 11(3):167-70. PubMed ID: 12380671
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Is there a relationship to dye determined or ultrasound estimated amniotic fluid volume adjusted percentiles and fetal weight adjusted percentiles?
    Magann EF; Doherty DA; Chauhan SP; Moses J; Newnham JP; Morrison JC
    Am J Obstet Gynecol; 2004 Jun; 190(6):1610-4; discussion 1614-5. PubMed ID: 15284751
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Amniotic fluid volume assessment: comparison of ultrasonographic estimates versus direct measurements with a dye-dilution technique in human pregnancy.
    Dildy GA; Lira N; Moise KJ; Riddle GD; Deter RL
    Am J Obstet Gynecol; 1992 Oct; 167(4 Pt 1):986-94. PubMed ID: 1415438
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Do semiquantitative amniotic fluid indexes reflect actual volume?
    Croom CS; Banias BB; Ramos-Santos E; Devoe LD; Bezhadian A; Hiett AK
    Am J Obstet Gynecol; 1992 Oct; 167(4 Pt 1):995-9. PubMed ID: 1415439
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Semiquantitative Assessment of Amniotic Fluid Among Individuals With and Without Diabetes Mellitus.
    Bicocca MJ; Qureshey EJ; Chauhan SP; Hernandez-Andrade E; Sibai BM; Nowlen C; Stafford I
    J Ultrasound Med; 2022 Feb; 41(2):447-455. PubMed ID: 33885190
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Antenatal fetal surveillance "Assessment of the AFV".
    Hughes DS; Magann EF
    Best Pract Res Clin Obstet Gynaecol; 2017 Jan; 38():12-23. PubMed ID: 27756534
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is There a Difference in Sonographic Estimation of Amniotic Fluid Volume When Measuring With the Probe Perpendicular to the Floor Compared With Perpendicular to the Uterine Contour?
    Hughes DS; Whittington JR; Kim H; Gunderman B; Ounpraseuth S; Magann EF
    J Obstet Gynaecol Can; 2019 Sep; 41(9):1295-1301. PubMed ID: 30910340
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Abnormal amniotic fluid volume as a screening test prior to targeted ultrasound.
    Blackwell SC; Hassan SS; Berry SM; Treadwell MC; Zador I; Wolfe HM
    Med Sci Monit; 2003 Nov; 9(11):MT119-22. PubMed ID: 14586286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.