177 related articles for article (PubMed ID: 9659188)
21. Validation of impedance cardiography measurements of cardiac output during limited exercise in heart transplant recipients.
Pepke-Zaba J; Higenbottam TW; Dinh Xuan AT; Scott JP; English TA; Wallwork J
Transpl Int; 1990 Jul; 3(2):108-12. PubMed ID: 2206215
[TBL] [Abstract][Full Text] [Related]
22. Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinations.
Pickett BR; Buell JC
Am J Cardiol; 1992 May; 69(16):1354-8. PubMed ID: 1585872
[TBL] [Abstract][Full Text] [Related]
23. Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output.
Villacorta Junior H; Villacorta AS; Amador F; Hadlich M; Albuquerque DC; Azevedo CF
Arq Bras Cardiol; 2012 Dec; 99(6):1149-55. PubMed ID: 23152290
[TBL] [Abstract][Full Text] [Related]
24. Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy.
Milsom I; Forssman L; Sivertsson R; Dottori O
Acta Obstet Gynecol Scand; 1983; 62(5):473-9. PubMed ID: 6364687
[TBL] [Abstract][Full Text] [Related]
25. Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM3 after coronary bypass surgery.
Thomas AN; Ryan J; Doran BR; Pollard BJ
Intensive Care Med; 1991; 17(7):383-6. PubMed ID: 1774390
[TBL] [Abstract][Full Text] [Related]
26. Measurements of cardiac output by impedance cardiography in pacemaker patients at rest: effects of various atrioventricular delays.
Ovsyshcher I; Zimlichman R; Katz A; Bondy C; Furman S
J Am Coll Cardiol; 1993 Mar; 21(3):761-7. PubMed ID: 8436759
[TBL] [Abstract][Full Text] [Related]
27. Non-invasive measurements of cardiac output in atrial fibrillation: inert gas rebreathing and impedance cardiography.
Osbak PS; Henriksen JH; Kofoed KF; Jensen GB
Scand J Clin Lab Invest; 2011 Jul; 71(4):304-13. PubMed ID: 21391778
[TBL] [Abstract][Full Text] [Related]
28. Noninvasive whole-body electrical bioimpedance cardiac output and invasive thermodilution cardiac output in high-risk surgical patients.
Imhoff M; Lehner JH; Löhlein D
Crit Care Med; 2000 Aug; 28(8):2812-8. PubMed ID: 10966255
[TBL] [Abstract][Full Text] [Related]
29. Could Impedance Cardiography be a Non-Invasive Alternative Method of Measuring Cardiac Output in Patients with Pulmonary Hypertension?
Yağmur B; Şimşek E; Kayıkçıoğlu M; Yüce Eİ; Bayazıt Candemir Y; Nalbantgil S; Moğolkoç N; Can L; Kültürsay H
Anatol J Cardiol; 2023 Nov; 27(11):650-656. PubMed ID: 37466025
[TBL] [Abstract][Full Text] [Related]
30. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study.
Haller M; Zöllner C; Briegel J; Forst H
Crit Care Med; 1995 May; 23(5):860-6. PubMed ID: 7736744
[TBL] [Abstract][Full Text] [Related]
31. Comparison of cardiac output derived from FloTrac™/Vigileo™ and impedance cardiography during major abdominal surgery.
Kim JY; Kim BR; Lee KH; Kim KW; Kim JH; Lee SI; Kim KT; Choe WJ; Park JS; Kim JW
J Int Med Res; 2013 Aug; 41(4):1342-9. PubMed ID: 23803309
[TBL] [Abstract][Full Text] [Related]
32. Impedance cardiography in the measurement of cardiac output: studies in rabbits.
Pappas CG; Wang X; Connolly RJ; Schwaitzberg SD
J Surg Res; 1995 Oct; 59(4):504-10. PubMed ID: 7564325
[TBL] [Abstract][Full Text] [Related]
33. Impedance cardiography derived cardiac output in hemodialysis patients: a study of reproducibility and comparison with echocardiography.
Karakitsos DN; Patrianakos AP; Paraskevopoulos A; Parthenakis FI; Tzenakis N; Fourtounas C; Daphnis EK; Vardas PE
Int J Artif Organs; 2006 Jun; 29(6):564-72. PubMed ID: 16841284
[TBL] [Abstract][Full Text] [Related]
34. Impedance cardiography and cardiac output in the elderly.
Williams BO; Caird FI
Age Ageing; 1980 Feb; 9(1):47-52. PubMed ID: 7361636
[TBL] [Abstract][Full Text] [Related]
35. Impedance cardiography: non-invasive cardiac output measurement after burn injury.
Griffths RW; Philpot ME; Chapman BJ; Munday KA
Int J Tissue React; 1981 Mar; 3(1):47-55. PubMed ID: 7287057
[TBL] [Abstract][Full Text] [Related]
36. [Comparative analysis of cardiac output determined by thermodilution, dye dilution and an impedance method in clinical application].
Feng JZ
Zhonghua Nei Ke Za Zhi; 1982 Sep; 21(9):533-5. PubMed ID: 6759072
[No Abstract] [Full Text] [Related]
37. Impedance cardiography: the failure of sternal electrodes to predict changes in stroke volume.
Patterson R; Wang L; McVeigh G; Burns R; Cohn J
Biol Psychol; 1993 Aug; 36(1-2):33-41. PubMed ID: 8218622
[TBL] [Abstract][Full Text] [Related]
38. Evaluation of impedance cardiography as a non-invasive means of measuring systolic time intervals and cardiac output.
Rasmussen JP; Sorensen B; Kann T
Acta Anaesthesiol Scand; 1975; 19(3):210-8. PubMed ID: 1101602
[TBL] [Abstract][Full Text] [Related]
39. Reliability of impedance cardiography in measuring central haemodynamics.
Mehlsen J; Bonde J; Stadeager C; Rehling M; Tangø M; Trap-Jensen J
Clin Physiol; 1991 Nov; 11(6):579-88. PubMed ID: 1769191
[TBL] [Abstract][Full Text] [Related]
40. [Measurement of cardiac output by thoracic electrical bioimpedance or thermodilution].
Jacob F; Mariot J; Frisoni A; Perrier JF; Voltz C; Strub P; Ethévenot G
Ann Fr Anesth Reanim; 1988; 7(3):264-7. PubMed ID: 3408040
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]