These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 9660034)

  • 1. Primary antecubital jump bypass grafts for hemoaccess.
    Barone GW; Hudec WA
    J Am Coll Surg; 1998 Jul; 187(1):106-7. PubMed ID: 9660034
    [No Abstract]   [Full Text] [Related]  

  • 2. A method to trim multilayered polytetrafluoroethylene grafts.
    Gelbfish GA; Vijay V
    J Am Coll Surg; 1996 Jun; 182(6):552-4. PubMed ID: 8646358
    [No Abstract]   [Full Text] [Related]  

  • 3. Necklace fistula for complicated dialysis access patients.
    Sirlak M; Eryilmaz S; Cakici M; Inan B; Kaya B; Ozyurda U
    Anadolu Kardiyol Derg; 2009 Feb; 9(1):64-5. PubMed ID: 19196579
    [No Abstract]   [Full Text] [Related]  

  • 4. Bovine carotid artery xenografts for hemodialysis access.
    Pineda DM; Dougherty MJ; Wismer MC; Carroll C; Tyagi S; Troutman DA; Calligaro KD
    J Vasc Surg; 2017 Jun; 65(6):1729-1734. PubMed ID: 28366301
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Regarding "autogenous radial-cephalic or prosthetic brachial-antecubital forearm loop avf in patients with compromised vessels? A randomized multicenter study of the patency of primary hemodialysis access".
    Turmel-Rodrigues L; Bourquelot P
    J Vasc Surg; 2006 Jun; 43(6):1315; author reply 1315-6. PubMed ID: 16765266
    [No Abstract]   [Full Text] [Related]  

  • 6. Early Cannulation of Bovine Carotid Artery Graft Reduces Tunneled Dialysis Catheter-Related Complications: A Comparison of Bovine Carotid Artery Graft Versus Expanded Polytetrafluoroethylene Grafts in Hemodialysis Access.
    Marcus P; Echeverria A; Cheung M; Kfoury E; Shim K; Lin PH
    Vasc Endovascular Surg; 2019 Feb; 53(2):104-111. PubMed ID: 30497352
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Infections associated with surgical implants.
    Roy-Chaudhury P; Munda R
    N Engl J Med; 2004 Jul; 351(2):193-5; author reply 193-5. PubMed ID: 15250067
    [No Abstract]   [Full Text] [Related]  

  • 8. Using a loop configured upper arm hemodialysis graft for the "hostile" arm.
    Barone GW; Lightfoot ML; Eidt JF
    J Ark Med Soc; 2003 Oct; 100(4):126-7. PubMed ID: 14560472
    [No Abstract]   [Full Text] [Related]  

  • 9. Hemodynamic data on polytetrafluoroethylene (PTFE) grafts.
    Kaye M; D'Avirro M; Baird C; McCloskey B; Oscar G
    Trans Am Soc Artif Intern Organs; 1979; 25():328-9. PubMed ID: 524600
    [No Abstract]   [Full Text] [Related]  

  • 10. Expanded polytetrafluoroethylene tube grafts for repeated vascular access.
    Jacobson JE; Pontin AR
    S Afr J Surg; 1979 Jun; 17(2):89-92. PubMed ID: 551541
    [No Abstract]   [Full Text] [Related]  

  • 11. Right atrial bypass grafting for central venous obstruction associated with dialysis access: another treatment option.
    El-Sabrout RA; Duncan JM
    J Vasc Surg; 1999 Mar; 29(3):472-8. PubMed ID: 10069911
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Autogenous radial-cephalic or prosthetic brachial-antecubital forearm loop AVF in patients with compromised vessels? A randomized, multicenter study of the patency of primary hemodialysis access.
    Rooijens PP; Burgmans JP; Yo TI; Hop WC; de Smet AA; van den Dorpel MA; Fritschy WM; de Groot HG; Burger H; Tordoir JH
    J Vasc Surg; 2005 Sep; 42(3):481-6; discussions 487. PubMed ID: 16171591
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Equivalent outcomes with standard and heparin-bonded expanded polytetrafluoroethylene grafts used as conduits for hemodialysis access.
    Davies MG; Anaya-Ayala JE; El-Sayed HF
    J Vasc Surg; 2016 Sep; 64(3):715-8. PubMed ID: 27183857
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Follow-up of polytetrafluoroethylene arteriovenous fistulae for haemodialysis.
    Modarai B; Dasgupta P; Taylor J; Koffman G; Khan MS
    Int J Clin Pract; 2005 Sep; 59(9):1005-7. PubMed ID: 16115172
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between bovine heterograft and expanded PTFE grafts for dialysis access.
    Lilly L; Nighiem D; Mendez-Picon G; Lee HM
    Am Surg; 1980 Dec; 46(12):694-6. PubMed ID: 7447169
    [No Abstract]   [Full Text] [Related]  

  • 16. Long-term results of biological grafts for haemodialysis vascular access.
    Inston NG
    J Vasc Access; 2015; 16 Suppl 9():S82-6. PubMed ID: 25751558
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safety and efficacy of polyurethane vascular grafts for early hemodialysis access.
    Kakisis JD; Antonopoulos C; Mantas G; Alexiou E; Katseni K; Sfyroeras G; Moulakakis K; Geroulakos G
    J Vasc Surg; 2017 Dec; 66(6):1792-1797. PubMed ID: 28865977
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Creation and use of a composite polyurethane-expanded polytetrafluoroethylene graft for hemodialysis access.
    Nakao A; Miyazaki M; Oka Y; Matsuda H; Oishi M; Kokumai Y; Kunitomo K; Isozaki H; Tanaka N
    Acta Med Okayama; 2000 Apr; 54(2):91-4. PubMed ID: 10806530
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of FLIXENEâ„¢ and standard PTFE arteriovenous graft for early haemodialysis.
    Chiang N; Hulme KR; Haggart PC; Vasudevan T
    J Vasc Access; 2014; 15(2):116-22. PubMed ID: 24531998
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of expanded polytetrafluoroethylene grafts for vascular access in hemodialysis: laboratory and clinical evaluation.
    Elliott MP; Gazzaniga AB; Thomas JM; Haiduc NJ; Rosen SM
    Am Surg; 1977 Jul; 43(7):455-9. PubMed ID: 879604
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]