190 related articles for article (PubMed ID: 9662782)
1. A comparison of indirect blood pressure monitoring techniques in the anesthetized cat.
Caulkett NA; Cantwell SL; Houston DM
Vet Surg; 1998; 27(4):370-7. PubMed ID: 9662782
[TBL] [Abstract][Full Text] [Related]
2. Doppler ultrasound is more accurate than pulse oximeter plethysmography in the measurement of systolic arterial pressure from the median caudal artery in anesthetized dogs.
Whittaker JH; Kapaldo N; Bortoluzzi EM; Rankin DC
Am J Vet Res; 2024 Jun; 85(6):. PubMed ID: 38503051
[TBL] [Abstract][Full Text] [Related]
3. Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs.
Bosiack AP; Mann FA; Dodam JR; Wagner-Mann CC; Branson KR
J Vet Emerg Crit Care (San Antonio); 2010 Apr; 20(2):207-15. PubMed ID: 20487248
[TBL] [Abstract][Full Text] [Related]
4. Doppler and oscillometric mean blood pressure best represent direct blood pressure measurements in anesthetized rhesus macaques (Macaca mulatta).
Kang SC; Jampachaisri K; Pacharinsak C
J Med Primatol; 2019 Apr; 48(2):123-128. PubMed ID: 30644561
[TBL] [Abstract][Full Text] [Related]
5. Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats.
Cerejo SA; Teixeira-Neto FJ; Garofalo NA; Rodrigues JC; Celeita-Rodríguez N; Lagos-Carvajal AP
J Vet Emerg Crit Care (San Antonio); 2017 Jul; 27(4):409-418. PubMed ID: 28654723
[TBL] [Abstract][Full Text] [Related]
6. Comparison of noninvasive blood pressure measurement techniques via the coccygeal artery in anesthetized cheetahs (Acinonyx jubatus).
Sadler RA; Hall NH; Kass PH; Citino SB
J Zoo Wildl Med; 2013 Dec; 44(4):928-35. PubMed ID: 24450051
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats.
Pedersen KM; Butler MA; Ersbøll AK; Pedersen HD
J Am Vet Med Assoc; 2002 Sep; 221(5):646-50. PubMed ID: 12216901
[TBL] [Abstract][Full Text] [Related]
8. Comparison of direct and Doppler arterial blood pressure measurements in rabbits during isoflurane anaesthesia.
Harvey L; Knowles T; Murison PJ
Vet Anaesth Analg; 2012 Mar; 39(2):174-84. PubMed ID: 22356416
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of an indirect oscillometric blood pressure monitor in normotensive and hypotensive anesthetized dogs.
Shih A; Robertson S; Vigani A; da Cunha A; Pablo L; Bandt C
J Vet Emerg Crit Care (San Antonio); 2010 Jun; 20(3):313-8. PubMed ID: 20636984
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs.
Sawyer DC; Guikema AH; Siegel EM
Vet Anaesth Analg; 2004 Jan; 31(1):27-39. PubMed ID: 14756751
[TBL] [Abstract][Full Text] [Related]
11. A comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows.
Caulkett NA; Duke T; Bailey JV
Can J Vet Res; 1994 Apr; 58(2):144-7. PubMed ID: 8004540
[TBL] [Abstract][Full Text] [Related]
12. Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats.
Binns SH; Sisson DD; Buoscio DA; Schaeffer DJ
J Vet Intern Med; 1995; 9(6):405-14. PubMed ID: 8558488
[TBL] [Abstract][Full Text] [Related]
13. Comparison of direct and indirect blood pressure measurements in anesthetized dogs.
Gains MJ; Grodecki KM; Jacobs RM; Dyson D; Foster RA
Can J Vet Res; 1995 Jul; 59(3):238-40. PubMed ID: 8521360
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of the Doppler ultrasonic method of measuring systolic arterial blood pressure in cats.
Grandy JL; Dunlop CI; Hodgson DS; Curtis CR; Chapman PL
Am J Vet Res; 1992 Jul; 53(7):1166-9. PubMed ID: 1497186
[TBL] [Abstract][Full Text] [Related]
15. Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs.
Grosenbaugh DA; Muir WW
Am J Vet Res; 1998 Feb; 59(2):205-12. PubMed ID: 9492938
[TBL] [Abstract][Full Text] [Related]
16. A comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in anaesthetised dogs, using tail and limb cuffs.
Bodey AR; Young LE; Bartram DH; Diamond MJ; Michell AR
Res Vet Sci; 1994 Nov; 57(3):265-9. PubMed ID: 7871243
[TBL] [Abstract][Full Text] [Related]
17. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.
Acierno MJ; da Cunha A; Smith J; Tully TN; Guzman DS; Serra V; Mitchell MA
J Am Vet Med Assoc; 2008 Nov; 233(10):1587-90. PubMed ID: 19014291
[TBL] [Abstract][Full Text] [Related]
18. Radial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement.
Weiss BM; Spahn DR; Rahmig H; Rohling R; Pasch T
Br J Anaesth; 1996 Mar; 76(3):405-11. PubMed ID: 8785142
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of an indirect oscillometric blood pressure monitor in anaesthetised dogs at three different anatomical locations.
Fujiyama M; Sano H; Chambers JP; Gieseg M
N Z Vet J; 2017 Jul; 65(4):185-191. PubMed ID: 28514936
[TBL] [Abstract][Full Text] [Related]
20. Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography.
Heishima Y; Hori Y; Chikazawa S; Kanai K; Hoshi F; Itoh N
J Vet Med Sci; 2016 Aug; 78(7):1179-82. PubMed ID: 27003226
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]