BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 9665422)

  • 41. Performance of a direct, immunoseparation based LDL-cholesterol method compared to Friedewald calculation and a polyvinyl sulphate precipitation method.
    Cobbaert C; Broodman I; Swart GR; Hoogerbrugge N
    Eur J Clin Chem Clin Biochem; 1995 Jul; 33(7):417-24. PubMed ID: 7548448
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Evolution of methods for measurement of HDL-cholesterol: from ultracentrifugation to homogeneous assays.
    Warnick GR; Nauck M; Rifai N
    Clin Chem; 2001 Sep; 47(9):1579-96. PubMed ID: 11514391
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Nonlinearity of high-density lipoprotein cholesterol determinations is matrix dependent.
    Kroll MH; Chesler R
    Clin Chem; 1994 Mar; 40(3):389-94. PubMed ID: 8131273
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Evaluation of a rapid homogeneous method for direct measurement of high-density lipoprotein cholesterol.
    Hubbard RS; Hirany SV; Devaraj S; Martin L; Parupia J; Jialal I
    Am J Clin Pathol; 1998 Oct; 110(4):495-502. PubMed ID: 9763036
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Validation of a novel homogeneous assay for of HDL3-C measurement.
    Ashmaig ME; Gupta S; McConnell JP; Warnick GR
    Clin Chim Acta; 2013 Oct; 425():37-41. PubMed ID: 23891742
    [TBL] [Abstract][Full Text] [Related]  

  • 46. New homogeneous HDL-cholesterol assay without the influence of high TG sample using the selective detergent to lipoproteins.
    Ueda Y; Matsui M; Hayashi S; Yamaguchi Y; Kanakura Y
    J Clin Lab Anal; 2003; 17(6):201-8. PubMed ID: 14614741
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Evaluation of the polyethylene glycol precipitation method for the estimation of chicken high density lipoprotein cholesterol.
    Mire SE; Snow LD
    Comp Biochem Physiol B; 1986; 84(1):105-10. PubMed ID: 3720287
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State.
    Miida T; Nishimura K; Hirayama S; Miyamoto Y; Nakamura M; Masuda D; Yamashita S; Ushiyama M; Komori T; Fujita N; Yokoyama S; Teramoto T
    J Atheroscler Thromb; 2017 Jun; 24(6):583-599. PubMed ID: 28321014
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Comparison of a new method for the direct and simultaneous assessment of LDL- and HDL-cholesterol with ultracentrifugation and established methods.
    Benlian P; Cansier C; Hennache G; Khallouf O; Bayer P; Duron F; Carrat F; Couderc R; Chazouillères O; Bardet J; Bouchard P; Poupon R; Masliah J; Béréziat G
    Clin Chem; 2000 Apr; 46(4):493-505. PubMed ID: 10759473
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Amperometric determination of high-density lipoprotein cholesterol using polyethylene glycol-modified enzymes and a peroxidase-entrapped electrode.
    Kinoshita H; Torimura M; Kano K; Ikeda T
    Ann Clin Biochem; 1998 Nov; 35 ( Pt 6)():739-44. PubMed ID: 9838987
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Determination of HDL-cholesterol].
    Herrmann W; Schütz C; Reuter W
    Z Gesamte Inn Med; 1983 Jan; 38(1):17-22. PubMed ID: 6342279
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin.
    Sugiuchi H; Uji Y; Okabe H; Irie T; Uekama K; Kayahara N; Miyauchi K
    Clin Chem; 1995 May; 41(5):717-23. PubMed ID: 7729051
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Fast lipoprotein chromatography: new method of analysis for plasma lipoproteins.
    März W; Siekmeier R; Scharnagl H; Seiffert UB; Gross W
    Clin Chem; 1993 Nov; 39(11 Pt 1):2276-81. PubMed ID: 8222220
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Evaluation of the accuracy of precipitation methods for HDL cholesterol determination].
    Barban G; Montanari D; Bertolini S; Reggiani E; Chiodini G; Elicio N; Jacopino GE; Balestreri R
    Boll Soc Ital Biol Sper; 1982 Feb; 58(3-4):99-105. PubMed ID: 6175325
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Separation of serum high-density lipoprotein for cholesterol determination: ultracentrifugation vs precipitation with sodium phosphotungstate and magnesium chloride.
    Seigler L; Wu WT
    Clin Chem; 1981 Jun; 27(6):838-41. PubMed ID: 7237761
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Further evidence for the heterogeneity of high density lipoprotein isolates: HDL2:HDL3 cholesterol ratios and the presence of apolipoprotein B.
    Rifai N; King ME
    Ann Clin Lab Sci; 1987; 17(5):345-9. PubMed ID: 2445254
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Studies of the accuracy of measurements of serum high density lipoprotein cholesterol levels.
    Clark DA; Garcia NJ; Rozell PR; Mosser EL
    Aviat Space Environ Med; 1984 Oct; 55(10):941-5. PubMed ID: 6208892
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Modification of the dextran-Mg2+ high-density lipoprotein cholesterol precipitation method for use with previously frozen plasma.
    McNamara JR; Huang C; Massov T; Leary ET; Warnick GR; Rubins HB; Robins SJ; Schaefer EJ
    Clin Chem; 1994 Feb; 40(2):233-9. PubMed ID: 7508829
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Procedure for effective separation of high-density lipoproteins in normal serum and hypertriglyceridemic samples.
    Lippi U; Graziani MS; Manzato F; Schinella M
    Clin Biochem; 1987 Oct; 20(5):313-5. PubMed ID: 3690831
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of two direct methods for HDL cholesterol measurement with an indirect precipitation method in diabetic patients.
    Saeed BO; Smart P; Keeka G; Handley GH; Weaver JU
    Diabetes Nutr Metab; 2002 Jun; 15(3):169-72. PubMed ID: 12173732
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.