BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 966791)

  • 21. [Comparison of ventricular fibrillation maintained by spontaneous, direct current stimuli and alternative current stimuli during cardiopulmonary bypass-with special reference to partial left ventricular hemodynamics and intramyocardial tissue pressure].
    Okumori M; Baird RJ
    Nihon Kyobu Geka Gakkai Zasshi; 1975 Jul; 23(7):833-8. PubMed ID: 1238461
    [No Abstract]   [Full Text] [Related]  

  • 22. A new pulsatile pump controlled by a roller system.
    Eguchi S; Asano K
    Surgery; 1968 Mar; 63(3):490-5. PubMed ID: 5644679
    [No Abstract]   [Full Text] [Related]  

  • 23. Hydraulic studies of aortic cannulation return nozzles.
    Hwang NH; Borik S; Noon GP; Kennedy JH
    Trans Am Soc Artif Intern Organs; 1975; 21():237-41. PubMed ID: 124974
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A compact centrifugal blood pump for extracorporeal circulation: design and performance.
    Tanaka S; Yamamoto S; Yamakoshi K; Kamiya A
    J Biomech Eng; 1987 Aug; 109(3):272-8. PubMed ID: 3657117
    [TBL] [Abstract][Full Text] [Related]  

  • 25. To pulse or not to pulse.
    Mavroudis C
    Ann Thorac Surg; 1978 Mar; 25(3):259-71. PubMed ID: 416759
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Clinical experience with a new pulsatile pump for infant and pediatric cardiopulmonary bypass.
    Fumero R; Montevecchi FM; Scuri S; Carrara B; Gamba A; Parenzan L
    Int J Artif Organs; 1989 May; 12(5):314-20. PubMed ID: 2661444
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Mechanically assisted circulation--hemodynamic evaluation of partial veno-arterial pulsatile circulatory assist with special reference to its effects on normal and ischemic fibrillating hearts].
    Tamura M; Matsukura H; Honma J; Kubota H; Ozawa T
    Nihon Kyobu Geka Gakkai Zasshi; 1972 Jun; 20(6):494-505. PubMed ID: 4676531
    [No Abstract]   [Full Text] [Related]  

  • 28. Comparison of a steady flow pump to a preload responsive pulsatile pump in left atrial-to-aorta bypass in canines.
    Runge TM; Grover FL; Cohen DJ; Bohls FO; Ottmers SE; Saadatmanesh V
    Artif Organs; 1991 Feb; 15(1):35-41. PubMed ID: 1998489
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Experimental extracorporeal circulation using ex-vivo homologous lungs as oxigenators, in the dog (author's transl)].
    Gyhra A; Boero D; Israel J; Maldonado R; Gouet G; Becerra E; Klassen R; Israel J; Godoy L; León J; Pierart J; Torres P
    Rev Med Chil; 1977 Mar; 105(3):164-7. PubMed ID: 887858
    [No Abstract]   [Full Text] [Related]  

  • 30. A simple device for achieving pulsatile flow during cardiopulmonary bypass.
    Desjardins J; Maillé JG; Lussier J; Grondin P
    Ann Thorac Surg; 1979 Feb; 27(2):178-80. PubMed ID: 453977
    [No Abstract]   [Full Text] [Related]  

  • 31. Continuous and pulsatile extracorporeal coronary perfusion in the beating and fibrillating swine myocardium: effects on left ventricular function.
    Moores WY; Hannon JP; Crum JD; Willford DS
    Surg Forum; 1977; 28():262-4. PubMed ID: 617438
    [No Abstract]   [Full Text] [Related]  

  • 32. The Minnesota system for cardiorespiratory assistance: test of a new system on dogs.
    Schultz LS; Koreski WR; Beckman CB; Romero LH; Motsay G; Dietzman RH; Lillehei RC
    Resuscitation; 1972 Sep; 1(3):183-99. PubMed ID: 4653746
    [No Abstract]   [Full Text] [Related]  

  • 33. Transapical left ventricular bypass (TALVB) without an auxiliary ventricle.
    Peters JL; McRea JC; Fukumasu H; Kolff WJ
    Trans Am Soc Artif Intern Organs; 1976; 22():357-66. PubMed ID: 951851
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A pulsatile assist device (PAD) for use during cardiopulmonary bypass.
    Bregman D; Bailin M; Bowman FO; Parodi EN; Haubert SM; Edie RN; Spotnitz HM; Reemtsma K; Malm JR
    Ann Thorac Surg; 1977 Dec; 24(6):574-81. PubMed ID: 596969
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [A new type of pump for support of the failing left ventricle].
    Bednarík B; Navrátil J; Tomecek J; Perestý S; Musil F
    Bratisl Lek Listy; 1968 Aug; 50(2):200-7. PubMed ID: 5685489
    [No Abstract]   [Full Text] [Related]  

  • 36. [Counterpulsation by means of a new device with a pulsatile blood flow in open heart operations (author's transl)].
    Bregman D; Parodi EN; Haubert SM; Szarnicki R; Edie RN; Spotnitz HM; Bowman FO; Reemtsma K; Malm JR
    Kardiologiia; 1978 Jul; 18(7):37-43. PubMed ID: 682412
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental evaluation of the Harvard pulsatile blood pump, Model No. 1405.
    Clark RE; Mills M
    Surgery; 1971 Jun; 69(6):917-23. PubMed ID: 5578452
    [No Abstract]   [Full Text] [Related]  

  • 38. Left ventricular bypass: a new nonthrombogenic device with homograft aortic valves.
    Wakabayashi A; Yim D; Dietrick W; Hirai JI; Connolly JE
    Am J Cardiol; 1970 Apr; 25(4):450-6. PubMed ID: 5438240
    [No Abstract]   [Full Text] [Related]  

  • 39. [Experimental study on left heart bypass using a pulsatile pump].
    Hata H
    Nihon Kyobu Geka Gakkai Zasshi; 1976 Mar; 24(3):300-10. PubMed ID: 944747
    [No Abstract]   [Full Text] [Related]  

  • 40. Development and evaluation of a new pulsatile ventricle pump for use in cardiopulmonary bypass.
    Bently DJ; Bivona JC; Pasupathy C; Sawyer PN; Stanczewski B
    Biomater Med Devices Artif Organs; 1973; 1(1):141-53. PubMed ID: 4766632
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.