These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
48. Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation. Corbisiero R; Lee MA; Nabert DR; Coman JA; Breiter DJ; Schwartz M; McKittrick E; Zhang Y Europace; 2006 Dec; 8(12):1057-61. PubMed ID: 17105781 [TBL] [Abstract][Full Text] [Related]
49. Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing. Kühlkamp V; Dörnberger V; Mewis C; Suchalla R; Bosch RF; Seipel L J Cardiovasc Electrophysiol; 1999 Jul; 10(7):905-15. PubMed ID: 10413370 [TBL] [Abstract][Full Text] [Related]
50. [Inadequate therapies with implantable cardioverter-defibrillators--incidence, etiology, predictive factors and preventive strategies]. Weber M; Block M; Brunn J; Bänsch D; Böcker D; Hammel D; Gietzen F; Breithardt G Z Kardiol; 1996 Nov; 85(11):809-19. PubMed ID: 9064943 [TBL] [Abstract][Full Text] [Related]
51. Morphology discriminator feature for enhanced ventricular tachycardia discrimination in implantable cardioverter defibrillators. Duru F; Bauersfeld U; Rahn-Schönbeck M; Candinas R Pacing Clin Electrophysiol; 2000 Sep; 23(9):1365-74. PubMed ID: 11025892 [TBL] [Abstract][Full Text] [Related]
52. Automatic arrhythmia identification using analysis of the atrioventricular association. Application to a new generation of implantable defibrillators. Participating Centers of the Automatic Recognition of Arrhythmia Study Group. Nair M; Saoudi N; Kroiss D; Letac B Circulation; 1997 Feb; 95(4):967-73. PubMed ID: 9054759 [TBL] [Abstract][Full Text] [Related]
53. Continuous template collection and updating for electrogram morphology discrimination in implantable cardioverter defibrillators. Compton SJ; Merrill JJ; Dorian P; Cao J; Zhou D; Gillberg JM; Pacing Clin Electrophysiol; 2006 Mar; 29(3):244-54. PubMed ID: 16606391 [TBL] [Abstract][Full Text] [Related]
54. Intracardiac QRS electrogram width--an arrhythmia detection feature for implantable cardioverter defibrillators: exercise induced variation as a base for device programming. Klingenheben T; Sticherling C; Skupin M; Hohnloser SH Pacing Clin Electrophysiol; 1998 Aug; 21(8):1609-17. PubMed ID: 9725161 [TBL] [Abstract][Full Text] [Related]
55. An adaptive interval-based algorithm for withholding ICD therapy during sinus tachycardia. Stadler RW; Gunderson BD; Gillberg JM Pacing Clin Electrophysiol; 2003 May; 26(5):1189-201. PubMed ID: 12765446 [TBL] [Abstract][Full Text] [Related]
57. Performance of basic ventricular tachycardia detection algorithms in implantable cardioverter defibrillators: implications for device programming. Anderson MH; Murgatroyd FD; Hnatkova K; Xie B; Jones S; Rowland E; Ward DE; Camm AJ; Malik M Pacing Clin Electrophysiol; 1997 Dec; 20(12 Pt 1):2975-83. PubMed ID: 9455760 [TBL] [Abstract][Full Text] [Related]
58. Postpacing Interval During Right Ventricular Overdrive Pacing to Discriminate Supraventricular from Ventricular tachycardia. Yalin K; Golcuk E; Karaayvaz EB; Aksu T; Arslane M; Tiryakioglu SK; Bilge AK; Adalet K J Atr Fibrillation; 2017; 10(2):1619. PubMed ID: 29250234 [TBL] [Abstract][Full Text] [Related]
59. Relative timing of near-field and far-field electrograms can determine the tachyarrhythmia site of origin. Caldwell J; Gula L; Ali FS; Miranda RI; Abdollah H; Baranchuk A; Michael K; Simpson C; Redfearn DP Heart Rhythm; 2018 Apr; 15(4):530-535. PubMed ID: 29246830 [TBL] [Abstract][Full Text] [Related]
60. Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators. Michael KA; Enriquez A; Baranchuk A; Haley C; Caldwell J; Simpson CS; Abdollah H; Redfearn DP Europace; 2015 Jan; 17(1):78-83. PubMed ID: 25031236 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]