  • 1. QT dependent T wave sensing.
    Böhm A; Pintér A; Préda I
    Pacing Clin Electrophysiol; 1998 Jul; 21(7):1490-1. PubMed ID: 9670199
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Polarization potentials causing pacemaker oversensing.
    Okreglicki A; Akiyama T; Ocampo C; Flynn D
    Jpn Circ J; 1998 Nov; 62(11):868-70. PubMed ID: 9856607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. P wave oversensing in a unipolar VVI pacemaker.
    van Gelder BM; Bracke FA; El Gamal MI
    Pacing Clin Electrophysiol; 1995 Feb; 18(2):370-3. PubMed ID: 7731887
    [TBL] [Abstract][Full Text] [Related]  

  • 4. VVI pacemaker ventricular undersensing.
    Johnson CD
    Bol Asoc Med P R; 1986 Jan; 78(1):21-5. PubMed ID: 3456750
    [No Abstract]   [Full Text] [Related]  

  • 5. Intermittent P wave sensing in a patient with DDD pacemaker.
    Paraskevaidis S; Mochlas S; Hadjimiltiadis S; Louridas G
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):689-90. PubMed ID: 10234728
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of programmed sensitivity safety factor on atrial sensing in children.
    Chiu CC; Gow RM; McCrindle BW; Hamilton RM
    Pacing Clin Electrophysiol; 1997 Sep; 20(9 Pt 1):2163-70. PubMed ID: 9309739
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intermittent mode reversion to VOO of a dual chamber pacemaker model.
    Erdogan O; Altun A; Ozbay G
    Pacing Clin Electrophysiol; 2001 Nov; 24(11):1704-5. PubMed ID: 11816646
    [TBL] [Abstract][Full Text] [Related]  

  • 8. P-wave sensing in VVI pacemakers: useful or a problem?
    van Gelder LM; el Gamal MI; Tielen CH
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1413-8. PubMed ID: 2462217
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ventricular capture by anodal pacemaker stimulation.
    Occhetta E; Bortnik M; Marino P
    Europace; 2006 May; 8(5):385-7. PubMed ID: 16636000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Malfunction of a permanent pacemaker].
    Barrera-Ramírez CF; Ilarraza-Lomelí H; Barragán-Campos H; Iturralde-Torres P
    Gac Med Mex; 2000; 136(2):159-62. PubMed ID: 10815326
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Atrial synchronous ventricular inhibited (VDD) pacemaker-mediated arrhythmia due to atrial undersensing and atrial lead oversensing of far-field ventricular afterpotentials or paced beats: crosstalk.
    Johnson CD
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):710-9. PubMed ID: 2429278
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Undersensing of P waves in the presence of an adequate P wave due to automatic postventricular atrial refractory period extension.
    Wilson JH; Lattner S
    Pacing Clin Electrophysiol; 1989 Nov; 12(11):1729-32. PubMed ID: 2478971
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Supraventricular tachycardia detected by means of an oesophageal Holter ECG in a patient with third-degree AV block and a VVI pacemaker.
    Grille W; Holst T; Laessing C; Schröder E; Asbeck F
    Eur Heart J; 1995 Dec; 16(12):2006-7. PubMed ID: 8682043
    [No Abstract]   [Full Text] [Related]  

  • 14. Diagnosis of atrial undersensing in dual chamber pacemakers: impact of autodiagnostic features.
    Wiegand UK; Bode F; Schneider R; Brandes A; Haase H; Katus HA; Potratz J
    Pacing Clin Electrophysiol; 1999 Jun; 22(6 Pt 1):894-902. PubMed ID: 10392387
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrical alternans of pacemaker spike amplitude: an unusual manifestation of permanent pacemaker generator malfunction.
    Austin SM; Kim CS; Solis A
    Pacing Clin Electrophysiol; 1981 May; 4(3):313-6. PubMed ID: 6169024
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Failure to sense P waves during DDD pacing.
    van Mechelen R; Hart C; de Boer H
    Pacing Clin Electrophysiol; 1986 Jul; 9(4):498-502. PubMed ID: 2426667
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Apparent P wave undersensing in a DDD pacemaker post exercise.
    van Gelder BM; van Mechelen R; den Dulk K; el Gamal MI
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 1):1651-6. PubMed ID: 1279530
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual-chamber pacemaker malfunction mimicking atrial capture by the ventricular electrode.
    Margos PN; Stefanidis AS; Papasteriadis EG
    Hellenic J Cardiol; 2011; 52(2):171-6. PubMed ID: 21478130
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Unusual presentation of DDD pacemaker system malfunction.
    Stark S; Farshidi A; Hager WD; Donaldson MC
    Pacing Clin Electrophysiol; 1985 Mar; 8(2):255-60. PubMed ID: 2580287
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A case of ventricular undersensing in the DDI mode: cause and correction.
    Bertuso J; Kapoor AS; Schafer J
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):685-9. PubMed ID: 2429274
    [TBL] [Abstract][Full Text] [Related]  