These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
304 related articles for article (PubMed ID: 9682207)
1. Superficial and orthovoltage x-ray beam dosimetry. Podgorsak EB; Gosselin M; Evans MD Med Phys; 1998 Jul; 25(7 Pt 1):1206-11. PubMed ID: 9682207 [TBL] [Abstract][Full Text] [Related]
2. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry. Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221 [TBL] [Abstract][Full Text] [Related]
3. Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co. Snow JR; Micka JA; DeWerd LA Med Phys; 2013 Apr; 40(4):041711. PubMed ID: 23556881 [TBL] [Abstract][Full Text] [Related]
4. Clinical implementation of AAPM TG61 protocol for kilovoltage x-ray beam dosimetry. Yoo S; Grimm D; Zhu R; Jursinic P; Lopez F; Rownd J; Gillin M Med Phys; 2002 Oct; 29(10):2269-73. PubMed ID: 12408301 [TBL] [Abstract][Full Text] [Related]
5. Head scatter off-axis for megavoltage x rays. Zhu TC; Bjärngard BE Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805 [TBL] [Abstract][Full Text] [Related]
6. Calculated absorbed-dose ratios, TG51/TG21, for most widely used cylindrical and parallel-plate ion chambers over a range of photon and electron energies. Tailor RC; Hanson WF Med Phys; 2002 Jul; 29(7):1464-72. PubMed ID: 12148727 [TBL] [Abstract][Full Text] [Related]
8. Effect of the diaphragm of free-air ionisation chamber for X-ray air-kerma measurements. Kurosawa T; Takata N; Saito N Radiat Prot Dosimetry; 2011 Jul; 146(1-3):195-7. PubMed ID: 21498414 [TBL] [Abstract][Full Text] [Related]
9. Development of improved free-air ionisation chamber as absolute dosimetry standard for low-energy X rays in INER. Chu CH; Kuan WP; Kurosawa T; Lin UT; Chen IJ; Chen WL Radiat Prot Dosimetry; 2010 Feb; 138(2):99-106. PubMed ID: 19789201 [TBL] [Abstract][Full Text] [Related]
10. Air kerma based dosimetry calibration for the Leksell Gamma Knife. Meltsner SG; DeWerd LA Med Phys; 2009 Feb; 36(2):339-50. PubMed ID: 19291973 [TBL] [Abstract][Full Text] [Related]
11. Air kerma calibration factors and chamber correction values for PTW soft x-ray, NACP and Roos ionization chambers at very low x-ray energies. Ipe NE; Rosser KE; Moretti CJ; Manning JW; Palmer MJ Phys Med Biol; 2001 Aug; 46(8):2107-17. PubMed ID: 11512614 [TBL] [Abstract][Full Text] [Related]
12. Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner. McCabe BP; Speidel MA; Pike TL; Van Lysel MS Med Phys; 2011 Apr; 38(4):1919-30. PubMed ID: 21626925 [TBL] [Abstract][Full Text] [Related]
13. Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols. Saiful Huq M; Song H; Andreo P; Houser CJ Med Phys; 2001 Oct; 28(10):2077-87. PubMed ID: 11695769 [TBL] [Abstract][Full Text] [Related]
14. An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams. Hill R; Mo Z; Haque M; Baldock C Med Phys; 2009 Sep; 36(9):3971-81. PubMed ID: 19810470 [TBL] [Abstract][Full Text] [Related]
15. DEVELOPMENT OF AN IONIZATION CHAMBER FOR LOW AND MEDIUM ENERGY PHOTON DOSIMETRY. Singh SK; Kulkarni MS Radiat Prot Dosimetry; 2018 Dec; 182(2):215-220. PubMed ID: 29660104 [TBL] [Abstract][Full Text] [Related]
16. Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer. Crosbie JC; Rogers PA; Stevenson AW; Hall CJ; Lye JE; Nordström T; Midgley SM; Lewis RA Med Phys; 2013 Jun; 40(6):062103. PubMed ID: 23718601 [TBL] [Abstract][Full Text] [Related]
17. Calibration of ionization chambers in air kerma length. Bochud FO; Grecescu M; Valley JF Phys Med Biol; 2001 Sep; 46(9):2477-87. PubMed ID: 11580183 [TBL] [Abstract][Full Text] [Related]
18. Comparison of dose calibration by ionometric and chemical dosimetry for 6- and 45-MV x-ray beams. Zwicker RD; Wu A; Sternick ES Med Phys; 1991; 18(6):1251-3. PubMed ID: 1753913 [TBL] [Abstract][Full Text] [Related]
19. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty. van Dijk E; Kolkman-Deurloo IK; Damen PM Med Phys; 2004 Oct; 31(10):2826-33. PubMed ID: 15543790 [TBL] [Abstract][Full Text] [Related]
20. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy. Hiatt JR; Rivard MJ; Hughes HG Med Phys; 2016 Mar; 43(3):1119-29. PubMed ID: 26936699 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]