These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
68. Extracorporeal left ventricular assistance with prostacyclin and heparinized centrifugal pump. Palatianos GM; Edmunds LH; Cohen DJ; Stephenson LW Ann Thorac Surg; 1983 May; 35(5):504-15. PubMed ID: 6342555 [TBL] [Abstract][Full Text] [Related]
69. Heparin-bonded surfaces in extracorporeal membrane oxygenation for cardiac support. von Segesser LK Ann Thorac Surg; 1996 Jan; 61(1):330-5; discussion 340-1. PubMed ID: 8561600 [TBL] [Abstract][Full Text] [Related]
70. Heparin clearance profiles after systemic anticoagulation using a heparin removal device system. Tao W; Callahan JD; Vertrees RA; Brunston RL; Deyo DJ; McRea JC; Zwischenberger JB ASAIO J; 1997; 43(6):922-6. PubMed ID: 9386844 [TBL] [Abstract][Full Text] [Related]
71. Extracorporeal membrane oxygenation with heparin-coated systems in a 13-month-old infant with acute hypoxic respiratory failure after correction of tetralogy of Fallot. Keh D; Rossaint R; Streich R; Gerlach H; Pappert D; Kramer H; Falke KJ Eur J Cardiothorac Surg; 1995; 9(4):226-9. PubMed ID: 7605651 [TBL] [Abstract][Full Text] [Related]
72. Prospects for clinical applications of polymer-coated haemoconcentrator on extracorporeal circuit in cardiopulmonary bypass surgeries. Tagaya M; Takahashi S; Matsuda M; Takasaki T; Hamaishi M; Hara K Int J Artif Organs; 2016 Oct; 39(8):415-420. PubMed ID: 27646632 [TBL] [Abstract][Full Text] [Related]
73. [The impact of heparin bolus from dysfunctional lumen of dual lumen central venous catheter on activated partial thromboplastin time during hemodialysis: is additional heparinization necessary?]. Sefer S; Kes P; Raić B; Heinrich B; Degoricija V; Szavits-Nossan J Acta Med Croatica; 2006 Jun; 60(3):281-5. PubMed ID: 16933844 [TBL] [Abstract][Full Text] [Related]
74. Heparin-induced thrombocytopenia in patients on extracorporeal membrane oxygenation and the role of a heparin-bonded circuit. Pabst D; Boone JB; Soleimani B; Brehm CE Perfusion; 2019 Oct; 34(7):584-589. PubMed ID: 30977431 [TBL] [Abstract][Full Text] [Related]
75. [Changes in platelets and blood coagulation during prolonged ECLA with a heparin bonded hollow fiber membrane lung]. Ezaki K Masui; 1990 Jul; 39(7):845-53. PubMed ID: 2214119 [TBL] [Abstract][Full Text] [Related]
76. Prolonged extracorporeal circulation without heparin. Evaluation of the Medtronic Minimax oxygenator. Shanley CJ; Hultquist KA; Rosenberg DM; McKenzie JM; Shah NL; Bartlett RH ASAIO J; 1992; 38(3):M311-6. PubMed ID: 1457872 [TBL] [Abstract][Full Text] [Related]
77. Adult ECMO performed with surface-heparinized equipment. Bindslev L ASAIO Trans; 1988; 34(4):1009-13. PubMed ID: 3219246 [TBL] [Abstract][Full Text] [Related]
78. Safety of heparin-coated circuits in primates during deep hypothermic cardiopulmonary bypass. Sistino JJ; Michler RE; Mongero LB; Schwartz A; Marboe C; Geiman R; Kwiatkowski P J Extra Corpor Technol; 1993; 25(1):15-21. PubMed ID: 10148570 [TBL] [Abstract][Full Text] [Related]
79. Tethered Liquid Perfluorocarbon Coating for 72 Hour Heparin-Free Extracorporeal Life Support. Roberts TR; Choi JH; Wendorff DS; Harea GT; Beely BM; Sieck KN; Douglass ME; Singha P; Dean JB; Handa H; Batchinsky AI ASAIO J; 2021 Jul; 67(7):798-808. PubMed ID: 33534236 [TBL] [Abstract][Full Text] [Related]
80. Comparison of pulsatile and nonpulsatile perfusion of the lung in an extracorporeal large animal model. Brandes H; Albes JM; Conzelmann A; Wehrmann M; Ziemer G Eur Surg Res; 2002; 34(4):321-9. PubMed ID: 12145559 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]