These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 9684957)

  • 1. Laminectomy and functional impairment of the lumbar spine: the importance of muscle forces in flexible and rigid instrumented stabilization--a biomechanical study in vitro.
    Quint U; Wilke HJ; Löer F; Claes L
    Eur Spine J; 1998; 7(3):229-38. PubMed ID: 9684957
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical analysis in a human cadaveric model of spinous process fixation with an interlaminar allograft spacer for lumbar spinal stenosis: Laboratory investigation.
    Pradhan BB; Turner AW; Zatushevsky MA; Cornwall GB; Rajaee SS; Bae HW
    J Neurosurg Spine; 2012 Jun; 16(6):585-93. PubMed ID: 22519928
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Functional sequelae of surgical decompression of the lumbar spine--a biomechanical study in vitro].
    Quint U; Wilke HJ; Löer F; Claes LE
    Z Orthop Ihre Grenzgeb; 1998; 136(4):350-7. PubMed ID: 9795438
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of an interspinous device and a rigid stabilization on lumbar adjacent segment range of motion.
    Hartmann F; Dietz SO; Kuhn S; Hely H; Rommens PM; Gercek E
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):404-9. PubMed ID: 22094153
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical testing of a PEEK-based dynamic instrumentation device in a lumbar spine model.
    Herren C; Beckmann A; Meyer S; Pishnamaz M; Mundt M; Sobottke R; Prescher A; Stoffel M; Markert B; Kobbe P; Pape HC; Eysel P; Siewe J
    Clin Biomech (Bristol, Avon); 2017 May; 44():67-74. PubMed ID: 28342975
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single level lumbar laminectomy alters segmental biomechanical behavior without affecting adjacent segments.
    Bisschop A; van Engelen SJ; Kingma I; Holewijn RM; Stadhouder A; van der Veen AJ; van Dieën JH; van Royen BJ
    Clin Biomech (Bristol, Avon); 2014 Sep; 29(8):912-7. PubMed ID: 25028214
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intradiscal pressure and kinematic behavior of lumbar spine after bilateral laminotomy and laminectomy.
    Rao RD; Wang M; Singhal P; McGrady LM; Rao S
    Spine J; 2002; 2(5):320-6. PubMed ID: 14589462
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Importance of the intersegmental trunk muscles for the stability of the lumbar spine. A biomechanical study in vitro.
    Quint U; Wilke HJ; Shirazi-Adl A; Parnianpour M; Löer F; Claes LE
    Spine (Phila Pa 1976); 1998 Sep; 23(18):1937-45. PubMed ID: 9779525
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical assessment of minimally invasive decompression for lumbar spinal canal stenosis: a cadaver study.
    Hamasaki T; Tanaka N; Kim J; Okada M; Ochi M; Hutton WC
    J Spinal Disord Tech; 2009 Oct; 22(7):486-91. PubMed ID: 20075811
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of limited interlaminar decompression versus complete laminectomy on intrathecal volume in degenerative lumbar spinal stenosis.
    Krämer R; Wild A; Haak H; Borowski S; Krauspe R
    Biomed Tech (Berl); 2002 Jun; 47(6):159-63. PubMed ID: 12149803
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of graded facetectomy and laminectomy on spinal biomechanics.
    Zander T; Rohlmann A; Klöckner C; Bergmann G
    Eur Spine J; 2003 Aug; 12(4):427-34. PubMed ID: 12720068
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis.
    Rohlmann A; Burra NK; Zander T; Bergmann G
    Eur Spine J; 2007 Aug; 16(8):1223-31. PubMed ID: 17206401
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical Evaluation of Lumbar Decompression Adjacent to Instrumented Segments.
    Grunert P; Reyes PM; Newcomb AG; Towne SB; Kelly BP; Theodore N; Härtl R
    Neurosurgery; 2016 Dec; 79(6):895-904. PubMed ID: 27580478
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Adjacent segment mobility after rigid and semirigid instrumentation of the lumbar spine.
    Cakir B; Carazzo C; Schmidt R; Mattes T; Reichel H; Käfer W
    Spine (Phila Pa 1976); 2009 May; 34(12):1287-91. PubMed ID: 19455004
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical effect of different interspinous devices on lumbar spinal range of motion under preload conditions.
    Hartmann F; Dietz SO; Hely H; Rommens PM; Gercek E
    Arch Orthop Trauma Surg; 2011 Jul; 131(7):917-26. PubMed ID: 21190031
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of the Total Facet Arthroplasty System after complete laminectomy-facetectomy on the biomechanics of implanted and adjacent segments.
    Phillips FM; Tzermiadianos MN; Voronov LI; Havey RM; Carandang G; Renner SM; Rosler DM; Ochoa JA; Patwardhan AG
    Spine J; 2009; 9(1):96-102. PubMed ID: 18440280
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical evaluation of a new total posterior-element replacement system.
    Wilke HJ; Schmidt H; Werner K; Schmölz W; Drumm J
    Spine (Phila Pa 1976); 2006 Nov; 31(24):2790-6; discussion 2797. PubMed ID: 17108830
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Which factors prognosticate rotational instability following lumbar laminectomy?
    Bisschop A; Kingma I; Bleys RL; van der Veen AJ; Paul CP; van Dieën JH; van Royen BJ
    Eur Spine J; 2013 Dec; 22(12):2897-903. PubMed ID: 24043337
    [TBL] [Abstract][Full Text] [Related]  

  • 19. How does spinal canal decompression and dorsal stabilization affect segmental mobility? A biomechanical study.
    Delank KS; Gercek E; Kuhn S; Hartmann F; Hely H; Röllinghoff M; Rothschild MA; Stützer H; Sobottke R; Eysel P
    Arch Orthop Trauma Surg; 2010 Feb; 130(2):285-92. PubMed ID: 19936771
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does superior-segment facet violation or laminectomy destabilize the adjacent level in lumbar transpedicular fixation? An in vitro human cadaveric assessment.
    Cardoso MJ; Dmitriev AE; Helgeson M; Lehman RA; Kuklo TR; Rosner MK
    Spine (Phila Pa 1976); 2008 Dec; 33(26):2868-73. PubMed ID: 19092616
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.