BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

233 related articles for article (PubMed ID: 9689268)

  • 1. Incidence of venous and paradoxical air embolism in neurosurgical patients in the sitting position: detection by transesophageal echocardiography.
    Mammoto T; Hayashi Y; Ohnishi Y; Kuro M
    Acta Anaesthesiol Scand; 1998 Jul; 42(6):643-7. PubMed ID: 9689268
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Venous air emboli occur during release of positive end-expiratory pressure and repositioning after sitting position surgery.
    Schmitt HJ; Hemmerling TM
    Anesth Analg; 2002 Feb; 94(2):400-3, table of contents. PubMed ID: 11812707
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The sitting position in neurosurgery: indications, complications and results. a single institution experience of 600 cases.
    Ganslandt O; Merkel A; Schmitt H; Tzabazis A; Buchfelder M; Eyupoglu I; Muenster T
    Acta Neurochir (Wien); 2013 Oct; 155(10):1887-93. PubMed ID: 23925859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Venous and paradoxical air embolism in the sitting position. A prospective study with transoesophageal echocardiography.
    Papadopoulos G; Kuhly P; Brock M; Rudolph KH; Link J; Eyrich K
    Acta Neurochir (Wien); 1994; 126(2-4):140-3. PubMed ID: 8042546
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Venous air embolism in the sitting position in cranial neurosurgery: incidence and severity according to the used monitoring.
    Günther F; Frank P; Nakamura M; Hermann EJ; Palmaers T
    Acta Neurochir (Wien); 2017 Feb; 159(2):339-346. PubMed ID: 27896454
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Contemporary analysis of the intraoperative and perioperative complications of neurosurgical procedures performed in the sitting position.
    Himes BT; Mallory GW; Abcejo AS; Pasternak J; Atkinson JLD; Meyer FB; Marsh WR; Link MJ; Clarke MJ; Perkins W; Van Gompel JJ
    J Neurosurg; 2017 Jul; 127(1):182-188. PubMed ID: 27494821
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Detection of venous air embolism and patent foramen ovale in neurosurgery patients in sitting position].
    Hervías A; Valero R; Hurtado P; Gracia I; Perelló L; Tercero FJ; González JJ; Fàbregas N
    Neurocirugia (Astur); 2014; 25(3):108-15. PubMed ID: 24630436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. TEE monitoring for RA-horizontal paradoxical arterial air embolism during sitting-position surgery.
    Ye X; Ma T; Wang T; Ge M; Wang C; Gao J; Li X
    Sci China Life Sci; 2010 Dec; 53(12):1405-9. PubMed ID: 21181341
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic detection of venous air embolism using transesophageal echocardiography in patients undergoing neurological surgery in the semi-sitting position: a pilot study.
    Rau TR; Plaschke K; Weigand MA; Maier C; Schramm C
    J Clin Monit Comput; 2021 Oct; 35(5):1103-1109. PubMed ID: 32809088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of the degree of head elevation on the incidence and severity of venous air embolism in cranial neurosurgical procedures with patients in the semisitting position.
    Türe H; Harput MV; Bekiroğlu N; Keskin Ö; Köner Ö; Türe U
    J Neurosurg; 2018 May; 128(5):1560-1569. PubMed ID: 28707996
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neurosurgical procedures in the semisitting position: evaluation of the risk of paradoxical venous air embolism in patients with a patent foramen ovale.
    Feigl GC; Decker K; Wurms M; Krischek B; Ritz R; Unertl K; Tatagiba M
    World Neurosurg; 2014 Jan; 81(1):159-64. PubMed ID: 23295634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Incidental detection of paradoxical air embolism with a transoesophageal Doppler probe inserted for measuring descending aortic blood flow.
    Draganov J; Scheeren TW
    Br J Anaesth; 2003 Apr; 90(4):520-2. PubMed ID: 12644431
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fifty percent nitrous oxide does not increase the risk of venous air embolism in neurosurgical patients operated upon in the sitting position.
    Losasso TJ; Muzzi DA; Dietz NM; Cucchiara RF
    Anesthesiology; 1992 Jul; 77(1):21-30. PubMed ID: 1609997
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Incidences of venous air embolism and patent foramen ovale among patients undergoing selective peripheral denervation in the sitting position.
    Girard F; Ruel M; McKenty S; Boudreault D; Chouinard P; Todorov A; Molina-Negro P; Bouvier G
    Neurosurgery; 2003 Aug; 53(2):316-9; discussion 319-20. PubMed ID: 12925246
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sitting position for neurosurgery: experience with preoperative contrast echocardiography in 301 patients.
    Schwarz G; Fuchs G; Weihs W; Tritthart H; Schalk HV; Kaltenböck F
    J Neurosurg Anesthesiol; 1994 Apr; 6(2):83-8. PubMed ID: 8012178
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Carbon dioxide field flooding reduces the hemodynamic effects of venous air embolism occurring in the sitting position.
    Longatti P; Marton E; Feletti A; Falzarano M; Canova G; Sorbara C
    Childs Nerv Syst; 2015 Aug; 31(8):1321-6. PubMed ID: 25953098
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The relationship between end-expired carbon dioxide tension and severity of venous air embolism during sitting neurosurgical procedures - A contemporary analysis.
    Kapurch CJ; Abcejo AS; Pasternak JJ
    J Clin Anesth; 2018 Dec; 51():49-54. PubMed ID: 30096518
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcranial Doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position.
    Stendel R; Gramm HJ; Schröder K; Lober C; Brock M
    Anesthesiology; 2000 Oct; 93(4):971-5. PubMed ID: 11020748
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preoperative and intraoperative echocardiography to detect right-to-left shunt in patients undergoing neurosurgical procedures in the sitting position.
    Black S; Muzzi DA; Nishimura RA; Cucchiara RF
    Anesthesiology; 1990 Mar; 72(3):436-8. PubMed ID: 2310022
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Clinical study on echocardiography combined with end-tidal CO2 monitoring in preventing the venous air embolism during operative hysteroscopy].
    Xu YQ; Zhang JX
    Zhonghua Fu Chan Ke Za Zhi; 2013 Nov; 48(11):828-32. PubMed ID: 24444559
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.