These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
295 related articles for article (PubMed ID: 9693890)
41. Colonoscopic polypectomy in retroflexion. Rex DK; Khashab M Gastrointest Endosc; 2006 Jan; 63(1):144-8. PubMed ID: 16377332 [TBL] [Abstract][Full Text] [Related]
42. Diagnosis of colorectal lesions with the magnifying narrow-band imaging system. Wada Y; Kudo SE; Kashida H; Ikehara N; Inoue H; Yamamura F; Ohtsuka K; Hamatani S Gastrointest Endosc; 2009 Sep; 70(3):522-31. PubMed ID: 19576581 [TBL] [Abstract][Full Text] [Related]
43. Safety, Feasibility, and Efficacy of Pancolonic Retroflexed Viewing Using a Short-turn Radius Colonoscope. Robles-Medranda C; Soria-AlcĂvar M; Oleas R; Vargas M; Ospina J; Abarca F; Puga-Tejada M; Baquerizo-Burgos J; Pitanga-Lukashok H J Clin Gastroenterol; 2019; 53(10):731-736. PubMed ID: 31135633 [TBL] [Abstract][Full Text] [Related]
44. Endocuff-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists. Pioche M; Matsumoto M; Takamaru H; Sakamoto T; Nakajima T; Matsuda T; Abe S; Kakugawa Y; Otake Y; Saito Y Surg Endosc; 2016 Jan; 30(1):288-95. PubMed ID: 25861907 [TBL] [Abstract][Full Text] [Related]
45. Miss rate of right-sided colon examination during colonoscopy defined by retroflexion: an observational study. Hewett DG; Rex DK Gastrointest Endosc; 2011 Aug; 74(2):246-52. PubMed ID: 21679946 [TBL] [Abstract][Full Text] [Related]
46. Endoscopic innovations to increase the adenoma detection rate during colonoscopy. Dik VK; Moons LM; Siersema PD World J Gastroenterol; 2014 Mar; 20(9):2200-11. PubMed ID: 24605019 [TBL] [Abstract][Full Text] [Related]
47. Short turn radius colonoscope in an anatomical model: retroflexed withdrawal and detection of hidden polyps. McGill SK; Kothari S; Friedland S; Chen A; Park WG; Banerjee S World J Gastroenterol; 2015 Jan; 21(2):593-9. PubMed ID: 25593483 [TBL] [Abstract][Full Text] [Related]
48. Transparent cap-assisted colonoscopy versus standard adult colonoscopy: a systematic review and meta-analysis. Westwood DA; Alexakis N; Connor SJ Dis Colon Rectum; 2012 Feb; 55(2):218-25. PubMed ID: 22228167 [TBL] [Abstract][Full Text] [Related]
49. Narrow-band imaging in addition to a transparent hood for much more polyp detection. Matsushita M; Omiya M; Uchida K; Nishio A; Okazaki K Gastrointest Endosc; 2009 Jan; 69(1):189-90; author reply 190-1. PubMed ID: 19111707 [No Abstract] [Full Text] [Related]
50. Narrow-band imaging colonoscopy--a pilot feasibility study for the detection of polyps and correlation of surface patterns with polyp histologic diagnosis. Rastogi A; Bansal A; Wani S; Callahan P; McGregor DH; Cherian R; Sharma P Gastrointest Endosc; 2008 Feb; 67(2):280-6. PubMed ID: 18155210 [TBL] [Abstract][Full Text] [Related]
51. Value of magnifying chromoendoscopy and narrow band imaging (NBI) in classifying colorectal polyps: a prospective controlled study. Tischendorf JJ; Wasmuth HE; Koch A; Hecker H; Trautwein C; Winograd R Endoscopy; 2007 Dec; 39(12):1092-6. PubMed ID: 18072061 [TBL] [Abstract][Full Text] [Related]
52. Colorectal polypectomy during insertion and withdrawal or only during withdrawal? A randomized controlled trial. Wildi SM; Schoepfer AM; Vavricka SR; Fruehauf H; Safroneeva E; Wiegand N; Bauerfeind P; Fried M Endoscopy; 2012 Nov; 44(11):1019-23. PubMed ID: 22930173 [TBL] [Abstract][Full Text] [Related]
53. CathCam guide wire-directed colonoscopy: first pilot study in patients with a previous incomplete colonoscopy. Fritscher-Ravens A; Fox S; Swain CP; Milla P; Long G Endoscopy; 2006 Mar; 38(3):209-13. PubMed ID: 16528644 [TBL] [Abstract][Full Text] [Related]
54. Increased incidence of colorectal adenomas in follow-up evaluation of patients with newly diagnosed hyperplastic polyps. Huang EH; Whelan RL; Gleason NR; Maeda JS; Terry MB; Lee SW; Neugut AI; Forde KA Surg Endosc; 2001 Jul; 15(7):646-8. PubMed ID: 11591960 [TBL] [Abstract][Full Text] [Related]
55. A retrograde-viewing device improves detection of adenomas in the colon: a prospective efficacy evaluation (with videos). Waye JD; Heigh RI; Fleischer DE; Leighton JA; Gurudu S; Aldrich LB; Li J; Ramrakhiani S; Edmundowicz SA; Early DS; Jonnalagadda S; Bresalier RS; Kessler WR; Rex DK Gastrointest Endosc; 2010 Mar; 71(3):551-6. PubMed ID: 20018280 [TBL] [Abstract][Full Text] [Related]
56. High accuracy of narrow band imaging without magnification for the real-time characterization of polyp histology and its comparison with high-definition white light colonoscopy: a prospective study. Rastogi A; Keighley J; Singh V; Callahan P; Bansal A; Wani S; Sharma P Am J Gastroenterol; 2009 Oct; 104(10):2422-30. PubMed ID: 19584829 [TBL] [Abstract][Full Text] [Related]
58. Efficacy of a distal attachment in endoscopic resection of colorectal polyps situated behind semilunar folds. Yoshikane H; Hidano H; Sakakibara A; Niwa Y; Goto H Endoscopy; 2001 May; 33(5):440-2. PubMed ID: 11396764 [TBL] [Abstract][Full Text] [Related]
59. Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes. Lee DW; Li AC; Ko CW; Chu DW; Chan KC; Poon CM; Sin KS; Leung KF; Sze TS; Chan AC; Chung SC Gastrointest Endosc; 2007 Mar; 65(3):424-9. PubMed ID: 17321243 [TBL] [Abstract][Full Text] [Related]
60. Quantitative colonoscopic evaluation of relative efficiencies of an immunochemical faecal occult blood test and a sensitive guaiac test for detecting significant colorectal neoplasms. Rozen P; Levi Z; Hazazi R; Waked A; Vilkin A; Maoz E; Birkenfeld S; Niv Y Aliment Pharmacol Ther; 2009 Feb; 29(4):450-7. PubMed ID: 19035980 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]