These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 9695273)
1. Ultrasound-induced temperature increase in the guinea-pig fetal brain in vitro. Horder MM; Barnett SB; Vella GJ; Edwards MJ Ultrasound Med Biol; 1998 Jun; 24(5):697-704. PubMed ID: 9695273 [TBL] [Abstract][Full Text] [Related]
2. Ultrasound-induced temperature increase in guinea-pig fetal brain in utero: third-trimester gestation. Horder MM; Barnett SB; Vella GJ; Edwards MJ; Wood AK Ultrasound Med Biol; 1998 Nov; 24(9):1501-10. PubMed ID: 10385971 [TBL] [Abstract][Full Text] [Related]
3. In vivo heating of the guinea-pig fetal brain by pulsed ultrasound and estimates of thermal index. Horder MM; Barnett SB; Vella GJ; Edwards MJ; Wood AK Ultrasound Med Biol; 1998 Nov; 24(9):1467-74. PubMed ID: 10385968 [TBL] [Abstract][Full Text] [Related]
4. Heating of guinea-pig fetal brain during exposure to pulsed ultrasound. Bosward KL; Barnett SB; Wood AK; Edwards MJ; Kossoff G Ultrasound Med Biol; 1993; 19(5):415-24. PubMed ID: 8356786 [TBL] [Abstract][Full Text] [Related]
5. Effects of pulsed ultrasound on sphenoid bone temperature and the heart rate in guinea-pig foetuses. Horder MM; Barnett SB; Vella GJ; Edwards MJ Early Hum Dev; 1998 Oct; 52(3):221-33. PubMed ID: 9808073 [TBL] [Abstract][Full Text] [Related]
6. Ultrasonic heating of the brain of the fetal sheep in utero. Duggan PM; Liggins GC; Barnett SB Ultrasound Med Biol; 1995; 21(4):553-60. PubMed ID: 7571148 [TBL] [Abstract][Full Text] [Related]
7. The cooling effect of liquid flow on the focussed ultrasound-induced heating in a simulated foetal brain. Vella GJ; Humphrey VF; Duck FA; Barnett SB Ultrasound Med Biol; 2003 Aug; 29(8):1193-204. PubMed ID: 12946522 [TBL] [Abstract][Full Text] [Related]
8. Intracranial temperature elevation from diagnostic ultrasound. Barnett SB Ultrasound Med Biol; 2001 Jul; 27(7):883-8. PubMed ID: 11476919 [TBL] [Abstract][Full Text] [Related]
9. Brain temperature during 340-kHz pulsed ultrasound insonation: a safety study for sonothrombolysis. Fatar M; Stroick M; Griebe M; Alonso A; Hennerici MG; Daffertshofer M Stroke; 2006 Jul; 37(7):1883-7. PubMed ID: 16741187 [TBL] [Abstract][Full Text] [Related]
11. Verification of fetal brain responses by coregistration of fetal ultrasound and fetal magnetoencephalography data. Micheli C; McCubbin J; Murphy P; Eswaran H; Lowery CL; Ortiz E; Preissl H Neuroimage; 2010 Jan; 49(2):1469-78. PubMed ID: 19778620 [TBL] [Abstract][Full Text] [Related]
12. Temperature rise generated by diagnostic ultrasound in a transcranial phantom. Wu J; Cubberley F; Gormley G; Szabo TL Ultrasound Med Biol; 1995; 21(4):561-8. PubMed ID: 7571149 [TBL] [Abstract][Full Text] [Related]
13. Ultrasound-induced heating in a foetal skull bone phantom and its dependence on beam width and perfusion. Vella GJ; Humphrey VF; Duck FA; Barnett SB Ultrasound Med Biol; 2003 Jun; 29(6):779-88. PubMed ID: 12837494 [TBL] [Abstract][Full Text] [Related]
15. MRI monitoring of heating produced by ultrasound absorption in the skull: in vivo study in pigs. McDannold N; King RL; Hynynen K Magn Reson Med; 2004 May; 51(5):1061-5. PubMed ID: 15122691 [TBL] [Abstract][Full Text] [Related]
16. The effects of prenatal ultrasound exposure on postnatal growth and acquisition of reflexes. Jensh RP; Lewin PA; Poczobutt MT; Goldberg BB; Oler J; Brent RL Radiat Res; 1994 Nov; 140(2):284-93. PubMed ID: 7938478 [TBL] [Abstract][Full Text] [Related]
17. Brain temperature and limits on transcranial cooling in humans: quantitative modeling results. Nelson DA; Nunneley SA Eur J Appl Physiol Occup Physiol; 1998 Sep; 78(4):353-9. PubMed ID: 9754976 [TBL] [Abstract][Full Text] [Related]
18. Comparison of the acoustic streaming in amniotic fluid and water in medical ultrasonic beams. Zauhar G; Duck FA; Starritt HC Ultraschall Med; 2006 Apr; 27(2):152-8. PubMed ID: 16612724 [TBL] [Abstract][Full Text] [Related]
19. Neonatal Cranial Ultrasound: Are Current Safety Guidelines Appropriate? Lalzad A; Wong F; Schneider M Ultrasound Med Biol; 2017 Mar; 43(3):553-560. PubMed ID: 27979665 [TBL] [Abstract][Full Text] [Related]