BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 9696581)

  • 1. 1,2-Diarylethylenediamines as sensitive pre-column derivatizing reagents for chemiluminescence detection of catecholamines in HPLC.
    Ragab GH; Nohta H; Kai M; Ohkura Y; Zaitsu K
    J Pharm Biomed Anal; 1995 Apr; 13(4-5):645-50. PubMed ID: 9696581
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A fully automated HPLC method for the determination of catecholamines in biological samples utilizing ethylenediamine condensation and peroxyoxalate chemiluminescence detection.
    Prados P; Higashidate S; Imai K
    Biomed Chromatogr; 1994; 8(1):1-8. PubMed ID: 8130626
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 1,2-Diarylethylenediamines as pre-column fluorescence derivatization reagents in high-performance liquid chromatographic determination of catecholamines in urine and plasma.
    Umegae Y; Nohta H; Lee M; Ohkura Y
    Chem Pharm Bull (Tokyo); 1990 Aug; 38(8):2293-5. PubMed ID: 2279295
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-performance liquid chromatography of plasma catecholamines using 1,2-diphenylethylenediamine as precolumn fluorescence derivatization reagent.
    Mitsui A; Nohta H; Ohkura Y
    J Chromatogr; 1985 Nov; 344():61-70. PubMed ID: 3003137
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of femtomole concentrations of catecholamines by high-performance liquid chromatography with peroxyoxalate chemiluminescence detection.
    Higashidate S; Imai K
    Analyst; 1992 Dec; 117(12):1863-8. PubMed ID: 1285577
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Catecholamine analysis with strong cation exchange column liquid chromatography-peroxyoxalate chemiluminescence reaction detection.
    Tsunoda M; Funatsu T
    Anal Bioanal Chem; 2012 Jan; 402(3):1393-7. PubMed ID: 22076313
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Application of bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)-phenyl]oxalate to post-column chemiluminescence detection in high-performance liquid chromatography.
    Imai K; Matsunaga Y; Tsukamoto Y; Nishitani A
    J Chromatogr; 1987 Jul; 400():169-76. PubMed ID: 3667744
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a chemiluminescence detection system using bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl] oxalate for the sensitive determination of the fluorescent compounds separated with an acidic mobile phase.
    Sugiura M; Kanda S; Imai K
    Biomed Chromatogr; 1993; 7(3):149-54. PubMed ID: 8318832
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic semi-microcolumn liquid chromatographic determination of catecholamines in rat plasma utilizing peroxyoxalate chemiluminescence reaction.
    Takezawa K; Tsunoda M; Murayama K; Santa T; Imai K
    Analyst; 2000 Feb; 125(2):293-6. PubMed ID: 10820891
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of free and total catecholamines in human urine by HPLC with fluorescence detection.
    Nohta H; Mitsui A; Umegae Y; Ohkura Y
    Biomed Chromatogr; 1987 Feb; 2(1):9-12. PubMed ID: 3508096
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous automatic determination of catecholamines and their 3-O-methyl metabolites in rat plasma by high-performance liquid chromatography using peroxyoxalate chemiluminescence reaction.
    Tsunoda M; Takezawa K; Santa T; Imai K
    Anal Biochem; 1999 May; 269(2):386-92. PubMed ID: 10222014
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sensitive detection of near-infrared fluorescent dyes using high-performance liquid chromatography with peroxyoxalate chemiluminescence detection system.
    Kimoto K; Gohda R; Murayama K; Santa T; Fukushima T; Homma H; Imai K
    Biomed Chromatogr; 1996; 10(4):189-90. PubMed ID: 8831965
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Studies on the effects of imidazole on the peroxyoxalate chemiluminescence detection system for high performance liquid chromatography.
    Imai K; Nishitani A; Tsukamoto Y; Wang WH; Kanda S; Hayakawa K; Miyazaki M
    Biomed Chromatogr; 1990 May; 4(3):100-4. PubMed ID: 2383689
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chemiluminescent detection of catecholamines by generation of hydrogen peroxide with imidazole.
    Nozaki O; Iwaeda T; Moriyama H; Kato Y
    Luminescence; 1999; 14(3):123-7. PubMed ID: 10423572
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous quantification of catecholamines in rat brain by high-performance liquid chromatography with on-line gold nanoparticle-catalyzed luminol chemiluminescence detection.
    Mu C; Zhang Q; Wu D; Zhang Y; Zhang Q
    Biomed Chromatogr; 2015 Jan; 29(1):148-55. PubMed ID: 24890328
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High performance liquid chromatography post-column chemiluminescence determination of sulfonamide residues in milk at low concentration levels using bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl] oxalate as chemiluminescent reagent.
    Soto-Chinchilla JJ; Gámiz-Gracia L; García-Campaña AM; Imai K; García-Ayuso LE
    J Chromatogr A; 2005 Nov; 1095(1-2):60-7. PubMed ID: 16275283
    [TBL] [Abstract][Full Text] [Related]  

  • 17. N-hydroxysuccinimidyl fluorescein-O-acetate as a fluorescent derivatizing reagent for catecholamines in liquid chromatography.
    Wang H; Li J; Liu X; Yang TX; Zhang HS
    Anal Biochem; 2000 May; 281(1):15-20. PubMed ID: 10847605
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High performance liquid chromatography with chemiluminescence detection of methamphetamine and its related compounds using 4-(N,N-dimethylaminosulphonyl)-7-fluoro-2,1,3-benzoxadiazole.
    Nakashima K; Suetsugu K; Yoshida K; Akiyama S; Uzu S; Imai K
    Biomed Chromatogr; 1992; 6(3):149-54. PubMed ID: 1525491
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-performance liquid chromatography with peroxyoxalate chemiluminescence detection of bisphenol A migrated from polycarbonate baby bottles using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a label.
    Sun Y; Wada M; Al-Dirbashi O; Kuroda N; Nakazawa H; Nakashima K
    J Chromatogr B Biomed Sci Appl; 2000 Nov; 749(1):49-56. PubMed ID: 11129078
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of maprotiline in plasma by high-performance liquid chromatography with chemiluminescence detection.
    Ishida J; Horike N; Yamaguchi M
    J Chromatogr B Biomed Appl; 1995 Jul; 669(2):390-6. PubMed ID: 7581917
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.