These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
155 related articles for article (PubMed ID: 9713633)
1. Changes in oxygen saturation and transcutaneous carbon dioxide and oxygen levels in patients undergoing fibreoptic bronchoscopy. Evans EN; Ganeshalingam K; Ebden P Respir Med; 1998 May; 92(5):739-42. PubMed ID: 9713633 [TBL] [Abstract][Full Text] [Related]
2. [Invasive or transcutaneous measurements of oxygen saturation and blood gases? An evaluation of pulse oximetry and transcutaneous measurement of PO2 and PCO2 during rest and exercise]. Stanghelle JK; Christensen CC; Haanaes OC Tidsskr Nor Laegeforen; 1993 Mar; 113(8):967-70. PubMed ID: 8470079 [TBL] [Abstract][Full Text] [Related]
3. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers]. Lehmann KA; Asoklis S; Grond S; Huttarsch H Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883 [TBL] [Abstract][Full Text] [Related]
6. A prospective observation study of the dynamic monitoring of transcutaneous arterial blood oxygen saturation and carbon dioxide during bronchoscopy. Shinozaki Y; Morikawa K; Hirotaka K; Nishiyama K; Tanaka S; Tsuruoka H; Matsuzawa S; Handa H; Nishine H; Mineshita M Respir Res; 2024 Oct; 25(1):361. PubMed ID: 39369209 [TBL] [Abstract][Full Text] [Related]
7. Usefulness of transcutaneous PCO2 to assess nocturnal hypoventilation in restrictive lung disorders. Georges M; Nguyen-Baranoff D; Griffon L; Foignot C; Bonniaud P; Camus P; Pepin JL; Rabec C Respirology; 2016 Oct; 21(7):1300-6. PubMed ID: 27185178 [TBL] [Abstract][Full Text] [Related]
8. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia. Rohling R; Biro P J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058 [TBL] [Abstract][Full Text] [Related]
9. Pulse oximetry in very low birth weight infants with acute and chronic lung disease. Ramanathan R; Durand M; Larrazabal C Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913 [TBL] [Abstract][Full Text] [Related]
10. Transcutaneous monitoring of blood gases: is it comparable with arterialized earlobe sampling? Dawson S; Cave C; Pavord I; Potter JF Respir Med; 1998 Mar; 92(3):584-7. PubMed ID: 9692127 [TBL] [Abstract][Full Text] [Related]
11. Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases. Pertzov B; Brachfeld E; Unterman A; Gershman E; Abdel-Rahman N; Rosengarten D; Kramer MR Lung; 2019 Feb; 197(1):67-72. PubMed ID: 30474708 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of transcutaneous carbon dioxide and saturation monitoring during fiberoptic bronchoscopy. Yumrukuz Şenel M; Fırat H; Kurt EB Tuberk Toraks; 2020 Dec; 68(4):379-387. PubMed ID: 33448735 [TBL] [Abstract][Full Text] [Related]
13. Detection of hypoventilation during thoracoscopy: combined cutaneous carbon dioxide tension and oximetry monitoring with a new digital sensor. Chhajed PN; Kaegi B; Rajasekaran R; Tamm M Chest; 2005 Feb; 127(2):585-8. PubMed ID: 15706000 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients. Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814 [TBL] [Abstract][Full Text] [Related]
15. Brain parenchyma PO2, PCO2, and pH during and after hypoxic, ischemic brain insult in dogs. McKinley BA; Morris WP; Parmley CL; Butler BD Crit Care Med; 1996 Nov; 24(11):1858-68. PubMed ID: 8917037 [TBL] [Abstract][Full Text] [Related]
16. Oxygen supplementation during awake fibreoptic bronchoscopy in a Nigerian tertiary hospital. Onakpoya UU; Adewole O; Ogunrombi AB; Adenekan AT West Afr J Med; 2012; 31(4):238-42. PubMed ID: 23468025 [TBL] [Abstract][Full Text] [Related]
17. A randomized, controlled trial of transcutaneous carbon dioxide monitoring during ERCP. Nelson DB; Freeman ML; Silvis SE; Cass OW; Yakshe PN; Vennes J; Stahnke LL; Herman M; Hodges J Gastrointest Endosc; 2000 Mar; 51(3):288-95. PubMed ID: 10699773 [TBL] [Abstract][Full Text] [Related]
18. Transcutaneous monitors during one-lung ventilation: are they reliable? Chung MR; Lichtor JL; Rangachari K; Roizen MF J Cardiothorac Anesth; 1988 Jun; 2(3):313-9. PubMed ID: 17171866 [TBL] [Abstract][Full Text] [Related]
19. Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation. Aarrestad S; Tollefsen E; Kleiven AL; Qvarfort M; Janssens JP; Skjønsberg OH Respir Med; 2016 Mar; 112():112-8. PubMed ID: 26874895 [TBL] [Abstract][Full Text] [Related]
20. Alveolar ventilation in children during flexible bronchoscopy. Sadot E; Gut G; Sivan Y Pediatr Pulmonol; 2016 Nov; 51(11):1177-1182. PubMed ID: 27061285 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]