136 related articles for article (PubMed ID: 9715442)
1. Experimental study of distal interlocking of a solid tibial nail: radiation-independent distal aiming device (DAD) versus freehand technique (FHT).
Krettek C; Könemann B; Farouk O; Miclau T; Kromm A; Tscherne H
J Orthop Trauma; 1998 Aug; 12(6):373-8. PubMed ID: 9715442
[TBL] [Abstract][Full Text] [Related]
2. [A comparison of a fluoroscopy-free mechanical targeting system and a free-hand technic for the placement of distal interlocking screws of tibial nails].
Krettek C; Könemann B; Farouk O; Kromm A; Schandelamier P; Tscherne H
Chirurg; 1997 Nov; 68(11):1194-201. PubMed ID: 9518215
[TBL] [Abstract][Full Text] [Related]
3. A mechanical distal aiming device for distal locking in femoral nails.
Krettek C; Könemann B; Miclau T; Kölbli R; Machreich T; Tscherne H
Clin Orthop Relat Res; 1999 Jul; (364):267-75. PubMed ID: 10416417
[TBL] [Abstract][Full Text] [Related]
4. Tibial intramedullary nail distal interlocking screw placement: comparison of the free-hand versus distally-based targeting device techniques.
Gugala Z; Nana A; Lindsey RW
Injury; 2001 Dec; 32 Suppl 4():SD21-5. PubMed ID: 11812474
[TBL] [Abstract][Full Text] [Related]
5. A new mechanical aiming device for the placement of distal interlocking screws in femoral nails.
Krettek C; Könemann B; Miclau T; Kölbli R; Machreich T; Kromm A; Tscherne H
Arch Orthop Trauma Surg; 1998; 117(3):147-52. PubMed ID: 9521519
[TBL] [Abstract][Full Text] [Related]
6. Intramedullary nailing for tibial shaft fractures in adults.
Duan X; Al-Qwbani M; Zeng Y; Zhang W; Xiang Z
Cochrane Database Syst Rev; 2012 Jan; 1():CD008241. PubMed ID: 22258982
[TBL] [Abstract][Full Text] [Related]
7. Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.
Windolf M; Schroeder J; Fliri L; Dicht B; Liebergall M; Richards RG
BMC Musculoskelet Disord; 2012 Jan; 13():8. PubMed ID: 22276698
[TBL] [Abstract][Full Text] [Related]
8. [Comparison of a radiation-independent aiming system and free-hand technique for distal locking of unslotted femoral nails].
Krettek C; Könemann B; Kölbli R; Machreich T; Kromm A; Tscherne H
Unfallchirurg; 1998 Nov; 101(11):822-9. PubMed ID: 9865164
[TBL] [Abstract][Full Text] [Related]
9. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
[TBL] [Abstract][Full Text] [Related]
10. Experimental model for a new distal locking aiming device for solid intramedullary tibia nails.
Abdlslam KM; Bonnaire F
Injury; 2003 May; 34(5):363-6. PubMed ID: 12719165
[TBL] [Abstract][Full Text] [Related]
11. The effectiveness of the external distal aiming device in intramedullary fixation of tibial shaft fractures.
Babis GC; Benetos IS; Zoubos AB; Soucacos PN
Arch Orthop Trauma Surg; 2007 Dec; 127(10):905-8. PubMed ID: 17641903
[TBL] [Abstract][Full Text] [Related]
12. Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study.
Aslan A; Konya MN; Gülcü A; Sargın S
Ulus Travma Acil Cerrahi Derg; 2020 Mar; 26(2):280-286. PubMed ID: 32185779
[TBL] [Abstract][Full Text] [Related]
13. Distal targeting device for long Gamma nail(®). Monocentric observational study.
Ehlinger M; Dillman G; Czekaj J; Adam P; Taglang G; Brinkert D; Schenck B; Di Marco A; Bonnomet F
Orthop Traumatol Surg Res; 2013 Nov; 99(7):799-804. PubMed ID: 24095597
[TBL] [Abstract][Full Text] [Related]
14. Distal locking of tibial nails : a new device to reduce radiation exposure.
Anastopoulos G; Ntagiopoulos PG; Chissas D; Papaeliou A; Asimakopoulos A
Clin Orthop Relat Res; 2008 Jan; 466(1):216-20. PubMed ID: 18196396
[TBL] [Abstract][Full Text] [Related]
15. The chessboard technique - a new freehand aiming method for rapid distal locking of tibial nails.
Salvi AE
Bull NYU Hosp Jt Dis; 2008; 66(4):317-9. PubMed ID: 19093909
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
[TBL] [Abstract][Full Text] [Related]
17. Insertion of distal locking screws of tibial intramedullary nails: a comparison between the free-hand technique and the SURESHOT™ Distal Targeting System.
Moreschini O; Petrucci V; Cannata R
Injury; 2014 Feb; 45(2):405-7. PubMed ID: 24140179
[TBL] [Abstract][Full Text] [Related]
18. Interlocking screws placed with freehand technique and uni-planar image intensification: the "dip-stick" technique.
Finelli CA; Ziran BH; Torini AP; Fernandes HJ; Dos Reis FB
Injury; 2014 Nov; 45 Suppl 5():S21-5. PubMed ID: 25528620
[TBL] [Abstract][Full Text] [Related]
19. Are there any advantages in using a distal aiming device for tibial nailing? Comparing the Centro Nailing System with the Unreamed Tibia Nail.
Veen EJ; Ettema HB; Zuurmond RG; Mostert AK
Injury; 2011 Oct; 42(10):1049-52. PubMed ID: 21549378
[TBL] [Abstract][Full Text] [Related]
20. Does the magnetic-guided intramedullary nailing technique shorten operation time and radiation exposure?
Dursun M; Kalkan T; Aytekin MN; Celik I; Uğurlu M
Eur J Orthop Surg Traumatol; 2014 Aug; 24(6):1005-11. PubMed ID: 23821246
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]