These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
418 related articles for article (PubMed ID: 9724112)
1. Defining thresholds for critical ischemia by using near-infrared spectroscopy in the adult brain. Kirkpatrick PJ; Lam J; Al-Rawi P; Smielewski P; Czosnyka M J Neurosurg; 1998 Sep; 89(3):389-94. PubMed ID: 9724112 [TBL] [Abstract][Full Text] [Related]
2. Resolving extra- and intracranial signal changes during adult near infrared spectroscopy. Kirkpatrick PJ; Smielewski P; Al-Rawi P; Czosnyka M Neurol Res; 1998; 20 Suppl 1():S19-22. PubMed ID: 9584918 [TBL] [Abstract][Full Text] [Related]
3. Impact of external carotid artery occlusion at declamping of the external and common carotid arteries during carotid endarterectomy on development of new postoperative ischemic cerebral lesions. Kobayashi M; Yoshida K; Kojima D; Oshida S; Fujiwara S; Kubo Y; Ogasawara K J Vasc Surg; 2019 Feb; 69(2):454-461. PubMed ID: 29960793 [TBL] [Abstract][Full Text] [Related]
5. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy. Pennekamp CW; Immink RV; den Ruijter HM; Kappelle LJ; Bots ML; Buhre WF; Moll FL; de Borst GJ Eur J Vasc Endovasc Surg; 2013 Oct; 46(4):397-403. PubMed ID: 23973277 [TBL] [Abstract][Full Text] [Related]
6. Hemodynamic cerebral ischemia during carotid endarterectomy evaluated by intraoperative monitoring and post-operative diffusion-weighted imaging. Uno M; Suzue A; Nishi K; Nagahiro S Neurol Res; 2007 Jan; 29(1):70-7. PubMed ID: 17427279 [TBL] [Abstract][Full Text] [Related]
7. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials. Moritz S; Kasprzak P; Arlt M; Taeger K; Metz C Anesthesiology; 2007 Oct; 107(4):563-9. PubMed ID: 17893451 [TBL] [Abstract][Full Text] [Related]
8. The contribution of the external carotid artery to cerebral perfusion in carotid disease. Fearn SJ; Picton AJ; Mortimer AJ; Parry AD; McCollum CN J Vasc Surg; 2000 May; 31(5):989-93. PubMed ID: 10805890 [TBL] [Abstract][Full Text] [Related]
9. Good correlation between cerebral oxygenation measured using near infrared spectroscopy and stump pressure during carotid clamping. Yamamoto K; Miyata T; Nagawa H Int Angiol; 2007 Sep; 26(3):262-5. PubMed ID: 17622209 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of a near-infrared spectrometer (NIRO 300) for the detection of intracranial oxygenation changes in the adult head. Al-Rawi PG; Smielewski P; Kirkpatrick PJ Stroke; 2001 Nov; 32(11):2492-500. PubMed ID: 11692006 [TBL] [Abstract][Full Text] [Related]
11. Optical topography can predict occurrence of watershed infarction during carotid endarterectomy: technical case report. Nakamura S; Kano T; Sakatani K; Hoshino T; Fujiwara N; Murata Y; Katayama Y Surg Neurol; 2009 May; 71(5):540-2. PubMed ID: 18291493 [TBL] [Abstract][Full Text] [Related]
12. Detection of cerebral ischemia in neurovascular surgery using quantitative frequency-domain near-infrared spectroscopy. Calderon-Arnulphi M; Alaraj A; Amin-Hanjani S; Mantulin WW; Polzonetti CM; Gratton E; Charbel FT J Neurosurg; 2007 Feb; 106(2):283-90. PubMed ID: 17410713 [TBL] [Abstract][Full Text] [Related]
13. Continuous transcranial Doppler ultrasonography and electroencephalography during carotid endarterectomy: a multimodal monitoring system to detect intraoperative ischemia. Jansen C; Moll FL; Vermeulen FE; van Haelst JM; Ackerstaff RG Ann Vasc Surg; 1993 Jan; 7(1):95-101. PubMed ID: 8518125 [TBL] [Abstract][Full Text] [Related]
14. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review. Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397 [TBL] [Abstract][Full Text] [Related]
15. External carotid artery shunting during carotid endarterectomy: an alternative for cerebral protection? Belardi P; Finocchi C; Lucertini G; Viacava A; Simoni G Eur J Vasc Endovasc Surg; 2001 Oct; 22(4):306-9. PubMed ID: 11563888 [TBL] [Abstract][Full Text] [Related]
16. Improvement of carotid blood flow after carotid endarterectomy--evaluation using intraoperative ultrasound flow measurement. Eckstein HH; Eichbaum M; Klemm K; Doerfler A; Ringleb P; Bruckner T; Allenberg JR Eur J Vasc Endovasc Surg; 2003 Feb; 25(2):168-74. PubMed ID: 12552480 [TBL] [Abstract][Full Text] [Related]
17. Outcome of Near-Infrared Spectroscopy-Guided Selective Shunting During Carotid Endarterectomy in General Anesthesia. Kondov S; Beyersdorf F; Schöllhorn J; Benk C; Rylski B; Czerny M; Harloff A; Siepe M Ann Vasc Surg; 2019 Nov; 61():170-177. PubMed ID: 31299276 [TBL] [Abstract][Full Text] [Related]
18. Intraoperative dual monitoring during carotid endarterectomy using motor evoked potentials and near-infrared spectroscopy. Uchino H; Nakamura T; Kuroda S; Houkin K; Murata J; Saito H World Neurosurg; 2012 Dec; 78(6):651-7. PubMed ID: 22120560 [TBL] [Abstract][Full Text] [Related]
19. Redistribution of blood flow after carotid endarterectomy. Gordon IL; Stemmer EA; Wilson SE J Vasc Surg; 1995 Oct; 22(4):349-58; discussion 358-60. PubMed ID: 7563396 [TBL] [Abstract][Full Text] [Related]
20. Early post-ischemic hyperemia on transcranial cerebral oxygen saturation monitoring in carotid endarterectomy is associated with severity of cerebral ischemic insult during carotid artery clamping. Kobayashi M; Ogasawara K; Suga Y; Chida K; Yoshida K; Otawara Y; Tsushima E; Ogawa A Neurol Res; 2009 Sep; 31(7):728-33. PubMed ID: 19108754 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]