These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 9725403)

  • 1. Delayed presentation of foreign body reaction secondary to retained pacing wires.
    Chung DA; Smith EE
    Ann Thorac Surg; 1998 Aug; 66(2):550-1. PubMed ID: 9725403
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pocket infection related to retained products of pacing.
    Hamid S; Patel N; Bucknall C
    Europace; 2008 Sep; 10(9):1122-3. PubMed ID: 18573780
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Retained temporary epicardial pacing wires: a rare cause of prosthetic valve endocarditis.
    Bashir A; Mustafa HM; Gunning M; Crossley I; Levine A; Wells D
    J Coll Physicians Surg Pak; 2013 Sep; 23(9):657-9. PubMed ID: 24034193
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Delayed granulomatous reaction and cutaneous fistula induced by retained electrodes from a cardiac pacemaker in a child.
    Sánchez-Los Arcos L; Feito-Rodríguez M; Rodríguez Bandera AI; González-López G; de Lucas-Laguna R
    Pediatr Dermatol; 2019 Jan; 36(1):e6-e11. PubMed ID: 30350442
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bilateral sternobronchial fistula after coronary surgery--are the retained epicardial pacing wires responsible? A case report.
    Sakellaridis T; Argiriou M; Panagiotakopoulos V; Charitos C
    J Cardiothorac Surg; 2009 Jun; 4():26. PubMed ID: 19552802
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pathological changes secondary to pacing leads within the coronary veins.
    Coelho-Lima J; Chapman J; Lim HS; Neil DAH
    Cardiovasc Pathol; 2020; 46():107197. PubMed ID: 32036174
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The formation of bronchocutaneous fistulae due to retained epicardial pacing wires: A literature review.
    Patris V; Argiriou M; Salem AL; Giakoumidakis K; Baikoussis NG; Charitos C
    Ann Card Anaesth; 2016; 19(4):683-686. PubMed ID: 27716700
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An unusual complication of coronary bypass surgery.
    Lyons C; Chaudhry M; O'Hern J
    Clin Cardiol; 1986 May; 9(5):215-6. PubMed ID: 3519032
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Mediastinal abscess as a remote complication of CABG combined with temporary cardiac pacing--a case report].
    Domaradzki W; Olszówka P; Mrozek R; Kargul T; Zurek P; Biernat J; Woś S
    Kardiol Pol; 2005 Jul; 63(7):70-2. PubMed ID: 16136435
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pausing With the Gauze: Inhibition of Temporary Pacemakers by Radiofrequency Scan During Cardiac Surgery.
    Williams MR; Atkinson DB; Bezzerides VJ; Yuki K; Franklin K; Casta A; Alexander ME
    Anesth Analg; 2016 Nov; 123(5):1143-1148. PubMed ID: 27644061
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mass in a pacemaker pocket.
    Li Q
    Kardiol Pol; 2017; 75(9):933. PubMed ID: 28895992
    [No Abstract]   [Full Text] [Related]  

  • 12. Migration of retained epicardial pacing wires.
    Domoto S; Nakazawa K; Tabata M; Niinami H
    Eur Heart J; 2016 Nov; 37(42):3246. PubMed ID: 26922811
    [No Abstract]   [Full Text] [Related]  

  • 13. Intra-operative arrhythmia predicts post-operative arrhythmia and the need for temporary pacing wires.
    Piggott K; Nehgme R; Decampli W; Pourmoghadam K; Fakioglu H; Blanco C
    Cardiol Young; 2015 Mar; 25(3):454-8. PubMed ID: 24495310
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A case of bloody sputum due to the migration of a temporary cardiac pacing lead into the bronchus].
    Ono K; Kaguraoka H; Itaoka T; Yokoyama M; Nitta S
    Nihon Kyobu Geka Gakkai Zasshi; 1997 Nov; 45(11):1903-6. PubMed ID: 9430976
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is use of temporary pacing wires following coronary bypass surgery really necessary?
    Imren Y; Benson AA; Oktar GL; Cheema FH; Comas G; Naseem T
    J Cardiovasc Surg (Torino); 2008 Apr; 49(2):261-7. PubMed ID: 18431348
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Case Image: Unexpected cause of lead fracture: A stylet left inside the right ventricular pacemaker lead.
    Ateş AH; Arslan U; Yücel H; Atasoy Günaydın İ; Yenerçağ M
    Turk Kardiyol Dern Ars; 2017 Jul; 45(5):486. PubMed ID: 28694406
    [No Abstract]   [Full Text] [Related]  

  • 17. Ventricular tachycardia associated with transmyocardial migration of an epicardial pacing wire.
    Meier DJ; Tamirisa KP; Eitzman DT
    Ann Thorac Surg; 2004 Mar; 77(3):1077-9. PubMed ID: 14992934
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Complications of retained epicardial pacing wires: an unusual bronchial foreign body.
    Gentry WH; Hassan AA
    Ann Thorac Surg; 1993 Dec; 56(6):1391-3. PubMed ID: 8267444
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Recurrent ventricular tachycardia in the postoperative period: the danger of malfunctioning epicardial pacing wires.
    Modi S; Barker D; Hawkins N; Hall M
    J Thorac Cardiovasc Surg; 2010 Sep; 140(3):e48-9. PubMed ID: 20471040
    [No Abstract]   [Full Text] [Related]  

  • 20. Transmyocardial voyage of a temporary epicardial lead: an unusual long-term complication.
    Sheikh M; Bruhl SR; Omer S; Schwaan T; Grubb B; Cooper C; Kanjwal Y
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):e185-6. PubMed ID: 21535035
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.