BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 9726315)

  • 1. Examination of wear in Duraloc acetabular components: two- to five-year evaluation of Hylamer and Enduron liners.
    Sychterz CJ; Shah N; Engh CA
    J Arthroplasty; 1998 Aug; 13(5):508-14. PubMed ID: 9726315
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Head penetration into Hylamer acetabular liner sterilized by gamma irradiation in air and in a nitrogen atmosphere.
    Yamauchi K; Hasegawa Y; Iwasada S; Sakano S; Kitamura S; Warashina H; Iwata H
    J Arthroplasty; 2001 Jun; 16(4):463-70. PubMed ID: 11402409
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles.
    Yan Y; Chen H; Feng J; Chen K; Zhou K; Hong W; Wang Y; Liu Z; Zhang J; Yang Q; Guo L; He C
    Int Orthop; 2017 Apr; 41(4):723-730. PubMed ID: 27178441
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Early osteolysis with Hylamer acetabular liners.
    Graeter JH; Nevins R
    J Arthroplasty; 1998 Jun; 13(4):464-6. PubMed ID: 9645529
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Early failure of Hylamer acetabular inserts due to eccentric wear.
    Chmell MJ; Poss R; Thomas WH; Sledge CB
    J Arthroplasty; 1996 Apr; 11(3):351-3. PubMed ID: 8713919
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sterilization and polyethylene wear: clinical studies to support laboratory data.
    Sychterz CJ; Orishimo KF; Engh CA
    J Bone Joint Surg Am; 2004 May; 86(5):1017-22. PubMed ID: 15118047
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An analysis of hylamer and polyethylene bearings from retrieved acetabular components.
    Collier JP; Bargmann LS; Currier BH; Mayor MB; Currier JH; Bargmann BC
    Orthopedics; 1998 Aug; 21(8):865-71. PubMed ID: 9731668
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner.
    Livingston BJ; Chmell MJ; Spector M; Poss R
    J Bone Joint Surg Am; 1997 Oct; 79(10):1529-38. PubMed ID: 9378739
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of head penetration into Hylamer and Enduron polyethylene liners: a follow-up report.
    Sychterz CJ; Young AM; McAuley JP; Engh CA
    J Arthroplasty; 2000 Apr; 15(3):372-4. PubMed ID: 10794235
    [No Abstract]   [Full Text] [Related]  

  • 10. Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.
    Ayers DC; Greene M; Snyder B; Aubin M; Drew J; Bragdon C
    J Bone Joint Surg Am; 2015 Apr; 97(8):627-34. PubMed ID: 25878306
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hylamer vs conventional polyethylene in primary total hip arthroplasty: a long-term case-control study of wear rates and osteolysis.
    Huddleston JI; Harris AH; Atienza CA; Woolson ST
    J Arthroplasty; 2010 Feb; 25(2):203-7. PubMed ID: 19264443
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The pros and cons of polyethylene sterilization with gamma irradiation.
    Hopper RH; Engh CA; Fowlkes LB; Engh CA
    Clin Orthop Relat Res; 2004 Dec; (429):54-62. PubMed ID: 15577466
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.
    Thomas GE; Simpson DJ; Mehmood S; Taylor A; McLardy-Smith P; Gill HS; Murray DW; Glyn-Jones S
    J Bone Joint Surg Am; 2011 Apr; 93(8):716-22. PubMed ID: 21508278
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty: A 10-Year Double-Blinded Randomized Controlled Trial.
    Devane PA; Horne JG; Ashmore A; Mutimer J; Kim W; Stanley J
    J Bone Joint Surg Am; 2017 Oct; 99(20):1703-1714. PubMed ID: 29040124
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time.
    Sychterz CJ; Engh CA; Shah N; Engh CA
    J Bone Joint Surg Am; 1997 Jul; 79(7):1040-6. PubMed ID: 9234880
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of Surface Finish and Dimensional Control of Tribological Metal-Ultra High Molecular Weight Polyethylene Pair of Commercially Available Hip Implants.
    Cubillos PO; Dos Santos VO; Pizzolatti ALA; da Rosa E; Roesler CRM
    J Arthroplasty; 2018 Mar; 33(3):939-944. PubMed ID: 29169690
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Early outcomes of sequentially cross-linked thin polyethylene liners with large diameter femoral heads in total hip arthroplasty.
    Sayeed SA; Mont MA; Costa CR; Johnson AJ; Naziri Q; Bonutti PM; Delanois RE
    Bull NYU Hosp Jt Dis; 2011; 69 Suppl 1():S90-4. PubMed ID: 22035492
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retrieval analysis of sequentially annealed highly crosslinked polyethylene used in total hip arthroplasty.
    Kurtz SM; MacDonald DW; Mont MA; Parvizi J; Malkani AL; Hozack W
    Clin Orthop Relat Res; 2015 Mar; 473(3):962-71. PubMed ID: 25537808
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hylamer wear rates and shelf life: a clinical correlation.
    Kiely PD; Harty JA; McElwain JP
    Acta Orthop Belg; 2005 Aug; 71(4):429-34. PubMed ID: 16184997
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Observation on retrieved Hylamer glenoids in shoulder arthroplasty: problems associated with sterilization by gamma irradiation in air.
    Rockwood CA; Wirth MA
    J Shoulder Elbow Surg; 2002; 11(2):191-7. PubMed ID: 11988733
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.