These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 9745699)

  • 1. Electron density of normal and pathological breast tissues using a Compton scattering technique.
    al-Bahri JS; Spyrou NM
    Appl Radiat Isot; 1998 Dec; 49(12):1677-84. PubMed ID: 9745699
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Photon linear attenuation coefficients and water content of normal and pathological breast tissues.
    al-Bahri JS; Spyrou NM
    Appl Radiat Isot; 1996 Aug; 47(8):777-84. PubMed ID: 8828159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The use of Compton scattering to differentiate between classifications of normal and diseased breast tissue.
    Ryan EA; Farquharson MJ; Flinton DM
    Phys Med Biol; 2005 Jul; 50(14):3337-48. PubMed ID: 16177513
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Gamma-ray scattering for fat fraction measurement.
    Shakeshaft J; Morgan HM; Lillicrap SC
    Phys Med Biol; 1997 Jul; 42(7):1403-13. PubMed ID: 9253048
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calculation of scattering cross sections for increased accuracy in diagnostic radiology. I. Energy broadening of Compton-scattered photons.
    Carlsson GA; Carlsson CA; Berggren KF; Ribberfors R
    Med Phys; 1982; 9(6):868-79. PubMed ID: 7162473
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The determination of electron density by the dual-energy Compton scatter method.
    Huddleston AL; Sackler JP
    Med Phys; 1985; 12(1):13-9. PubMed ID: 3974520
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of tissue via coherent-to-Compton scattering ratio: sensitivity considerations.
    Karellas A; Leichter I; Craven JD; Greenfield MA
    Med Phys; 1983; 10(5):605-9. PubMed ID: 6646064
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The measurement of trabecular bone mineral density using coherent and Compton scattered photons in vitro.
    Ling SS; Rustgi S; Karellas A; Craven JD; Whiting JS; Greenfield MA; Stern R
    Med Phys; 1982; 9(2):208-15. PubMed ID: 7087905
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Practical aspects of Compton scatter densitometry.
    Sharaf JM
    Appl Radiat Isot; 2001 May; 54(5):801-9. PubMed ID: 11258530
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Study of electron densities of normal and neoplastic human breast tissues by Compton scattering using synchrotron radiation.
    Antoniassi M; Conceição AL; Poletti ME
    Appl Radiat Isot; 2012 Jul; 70(7):1351-4. PubMed ID: 22264794
    [TBL] [Abstract][Full Text] [Related]  

  • 11. X-ray scattering from human breast tissues and breast-equivalent materials.
    Poletti ME; Gonçalves D; Mazzaro I
    Phys Med Biol; 2002 Jan; 47(1):47-63. PubMed ID: 11814227
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The role of Compton background and breast compression on cancer detection in scintimammography.
    Pani R; Scopinaro F; Pellegrini R; Soluri A; Weinberg IN; De Vincentis G
    Anticancer Res; 1997; 17(3B):1645-9. PubMed ID: 9179211
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An iterative three-dimensional electron density imaging algorithm using uncollimated compton scattered x rays from a polyenergetic primary pencil beam.
    Van Uytven E; Pistorius S; Gordon R
    Med Phys; 2007 Jan; 34(1):256-65. PubMed ID: 17278511
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Compton scattering spectrum as a source of information of normal and neoplastic breast tissues' composition.
    Antoniassi M; Conceição AL; Poletti ME
    Appl Radiat Isot; 2012 Jul; 70(7):1451-5. PubMed ID: 22398323
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Breast tissue classification using x-ray scattering measurements and multivariate data analysis.
    Ryan EA; Farquharson MJ
    Phys Med Biol; 2007 Nov; 52(22):6679-96. PubMed ID: 17975291
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of bone density by coherent-Compton scattering.
    Stalp JT; Mazess RB
    Med Phys; 1980; 7(6):723-6. PubMed ID: 7464719
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mammographic x-ray spectra measured by Compton spectroscopy using a high resolution Schottky CdTe detector.
    Maeda K; Matsumoto M
    Igaku Butsuri; 2004; 24(4):131-41. PubMed ID: 15795501
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Post mastectomy chest wall irradiation using mixed electron-photon beams with or without isocentric technique.
    Hamdy HK; Zikry MS
    Gulf J Oncolog; 2008 Jan; (3):33-40. PubMed ID: 20084795
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of detector collimator and sample thickness on 0.662 MeV multiply Compton-scattered gamma rays.
    Singh M; Singh G; Sandhu BS; Singh B
    Appl Radiat Isot; 2006 Mar; 64(3):373-8. PubMed ID: 16307888
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Small-angle x-ray scattering studies of human breast tissue samples.
    Fernández M; Keyriläinen J; Serimaa R; Torkkeli M; Karjalainen-Lindsberg ML; Tenhunen M; Thomlinson W; Urban V; Suortti P
    Phys Med Biol; 2002 Feb; 47(4):577-92. PubMed ID: 11900192
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.