These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 9745808)

  • 1. [Algorithm for automatic endocardium identification in digital echocardiography image sequences].
    Santos Conde JE; Teuner A; Pichler O; Hosticka BJ
    Biomed Tech (Berl); 1998; 43(7-8):221-6. PubMed ID: 9745808
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Segmentation of the heart muscle in 3-D pediatric echocardiographic images.
    Nillesen MM; Lopata RG; Gerrits IH; Kapusta L; Huisman HJ; Thijssen JM; de Korte CL
    Ultrasound Med Biol; 2007 Sep; 33(9):1453-62. PubMed ID: 17574727
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endocardial boundary extraction in left ventricular echocardiographic images using fast and adaptive B-spline snake algorithm.
    Marsousi M; Eftekhari A; Kocharian A; Alirezaie J
    Int J Comput Assist Radiol Surg; 2010 Sep; 5(5):501-13. PubMed ID: 20232263
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Segmentation and tracking in echocardiographic sequences: active contours guided by optical flow estimates.
    Mikić I; Krucinski S; Thomas JD
    IEEE Trans Med Imaging; 1998 Apr; 17(2):274-84. PubMed ID: 9688159
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Combining multiple dynamic models and deep learning architectures for tracking the left ventricle endocardium in ultrasound data.
    Carneiro G; Nascimento JC
    IEEE Trans Pattern Anal Mach Intell; 2013 Nov; 35(11):2592-607. PubMed ID: 24051722
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spatio-Temporal Segmentation in 3-D Echocardiographic Sequences Using Fractional Brownian Motion.
    Al-Kadi OS
    IEEE Trans Biomed Eng; 2020 Aug; 67(8):2286-2296. PubMed ID: 31831403
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Adaptive image inversion of contrast 3D echocardiography for enabling automated analysis.
    Shaheen A; Rajpoot K
    Comput Biol Med; 2015 Aug; 63():99-107. PubMed ID: 26046500
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic detection of left ventricular borders on electron beam CT sequential cardiac images using an adaptive algorithm.
    Herment A; Mousseaux E; Dumée P; Decesare A
    Comput Med Imaging Graph; 1998; 22(4):291-9. PubMed ID: 9840659
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel myocardium segmentation approach based on neutrosophic active contour model.
    Guo Y; Du GQ; Xue JY; Xia R; Wang YH
    Comput Methods Programs Biomed; 2017 Apr; 142():109-116. PubMed ID: 28325439
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of left ventricular cardiac shape by the use of volumetric curvature analysis from 3D echocardiography.
    Duann JR; Chiang SH; Lin SB; Lin CC; Chen JH; Su JL
    Comput Med Imaging Graph; 1999; 23(2):89-101. PubMed ID: 10227375
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Standardized Evaluation System for Left Ventricular Segmentation Algorithms in 3D Echocardiography.
    Bernard O; Bosch JG; Heyde B; Alessandrini M; Barbosa D; Camarasu-Pop S; Cervenansky F; Valette S; Mirea O; Bernier M; Jodoin PM; Domingos JS; Stebbing RV; Keraudren K; Oktay O; Caballero J; Shi W; Rueckert D; Milletari F; Ahmadi SA; Smistad E; Lindseth F; van Stralen M; Wang C; Smedby O; Donal E; Monaghan M; Papachristidis A; Geleijnse ML; Galli E; D'hooge J
    IEEE Trans Med Imaging; 2016 Apr; 35(4):967-77. PubMed ID: 26625409
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endocardial border identification in two-dimensional echocardiographic images: review of methods.
    Hammoude A
    Comput Med Imaging Graph; 1998; 22(3):181-93. PubMed ID: 9740036
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Star algorithm: detecting the ultrasonic endocardial boundary automatically.
    Yao W; Tian J; Zhao B; Chen N; Qian G
    Ultrasound Med Biol; 2004 Jul; 30(7):943-51. PubMed ID: 15313326
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Computer-assisted analysis of ultrasound sequences of the left ventricle for determining ejection fraction].
    Hackstein J; Pichler O; Teuner A
    Biomed Tech (Berl); 1996 May; 41(5):118-22. PubMed ID: 8737526
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficient workflow for automatic segmentation of the right heart based on 2D echocardiography.
    Danilov VV; Skirnevskiy IP; Gerget OM; Shelomentcev EE; Kolpashchikov DY; Vasilyev NV
    Int J Cardiovasc Imaging; 2018 Jul; 34(7):1041-1055. PubMed ID: 29428969
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Segmentation of left ventricle in short-axis echocardiographic sequences by weighted radial edge filtering and adaptive recovery of dropout regions.
    Bansod P; Desai UB; Merchant SN; Burkule N
    Comput Methods Biomech Biomed Engin; 2011 Jul; 14(7):603-13. PubMed ID: 21390933
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tissue harmonic imaging for standard left ventricular measurements: fundamentally flawed?
    Turner SP; Monaghan MJ
    Eur J Echocardiogr; 2006 Jan; 7(1):9-15. PubMed ID: 16219493
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The extracting of left ventricular contour based on adaptive directional filter].
    Ji Z; Mou X; Cai Y
    Zhongguo Yi Liao Qi Xie Za Zhi; 1999 Sep; 23(5):252-7. PubMed ID: 12583068
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Computerized processing of two-dimensional echo-cardiograms: its application for quantitating left ventricular regional contractility and three-dimensional echocardiography].
    Fujii J; Sawada H; Okabe A; Aizawa T; Ogasawara K; Watanabe H; Ohta A; Kato K; Onoe M; Kuno Y
    J Cardiogr Suppl; 1984; (3):3-21. PubMed ID: 6536691
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated 3-D echocardiography analysis compared with manual delineations and SPECT MUGA.
    Sanchez-Ortiz GI; Wright GJ; Clarke N; Declerck J; Banning AP; Noble JA
    IEEE Trans Med Imaging; 2002 Sep; 21(9):1069-76. PubMed ID: 12564875
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.