These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

326 related articles for article (PubMed ID: 9747795)

  • 21. Compliant positioning of total hip components for optimal range of motion.
    Widmer KH; Zurfluh B
    J Orthop Res; 2004 Jul; 22(4):815-21. PubMed ID: 15183439
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Guidelines for implant placement to minimize impingement during activities of daily living after total hip arthroplasty.
    Patel AB; Wagle RR; Usrey MM; Thompson MT; Incavo SJ; Noble PC
    J Arthroplasty; 2010 Dec; 25(8):1275-81.e1. PubMed ID: 20022449
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Accuracy improvement of acetabular component placement using non-image based surgical navigation system].
    Yu Z; Wang L; Gui J
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2007 Oct; 21(10):1057-61. PubMed ID: 17990769
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optimal acetabular component orientation estimated using edge-loading and impingement risk in patients with metal-on-metal hip resurfacing arthroplasty.
    Mellon SJ; Grammatopoulos G; Andersen MS; Pandit HG; Gill HS; Murray DW
    J Biomech; 2015 Jan; 48(2):318-23. PubMed ID: 25482661
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Hip centralising forces of the iliotibial tract with various femoral neck angles].
    Birnbaum K; Pandorf T; Prescher A; Niethard FU; Weisskopf M
    Z Orthop Unfall; 2009; 147(3):341-9. PubMed ID: 19551586
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Metal-on-metal hip resurfacing: the effect of cup position and component size on range of motion to impingement.
    Williams D; Royle M; Norton M
    J Arthroplasty; 2009 Jan; 24(1):144-51. PubMed ID: 18823742
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement.
    Kluess D; Martin H; Mittelmeier W; Schmitz KP; Bader R
    Med Eng Phys; 2007 May; 29(4):465-71. PubMed ID: 16901743
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Theoretically optimum position of the prosthesis in total hip arthroplasty to fulfill the severe range of motion criteria due to neck impingement.
    Hisatome T; Doi H
    J Orthop Sci; 2011 Mar; 16(2):229-37. PubMed ID: 21359509
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimal orientation of implanted components in total hip arthroplasty with polyethylene on metal articulation.
    Ko BH; Yoon YS
    Clin Biomech (Bristol, Avon); 2008 Oct; 23(8):996-1003. PubMed ID: 18550233
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.
    Lin F; Lim D; Wixson RL; Milos S; Hendrix RW; Makhsous M
    Clin Biomech (Bristol, Avon); 2008 Oct; 23(8):1004-11. PubMed ID: 18541352
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Surgical treatment of femoroacetabular impingement improves hip kinematics: a computer-assisted model.
    Bedi A; Dolan M; Hetsroni I; Magennis E; Lipman J; Buly R; Kelly BT
    Am J Sports Med; 2011 Jul; 39 Suppl():43S-9S. PubMed ID: 21709031
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Strict component positioning is necessary in hip resurfacing.
    Kajino Y; Kabata T; Maeda T; Iwai S; Kuroda K; Fujita K; Tsuchiya H
    J Orthop Sci; 2013 Mar; 18(2):290-7. PubMed ID: 23315180
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter.
    Kluess D; Zietz C; Lindner T; Mittelmeier W; Schmitz KP; Bader R
    Acta Orthop; 2008 Dec; 79(6):748-54. PubMed ID: 19085490
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty?
    Müller M; Abdel MP; Wassilew GI; Duda G; Perka C
    Bone Joint J; 2015 Dec; 97-B(12):1615-22. PubMed ID: 26637674
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Unconstrained tripolar hip implants: effect on hip stability.
    Guyen O; Chen QS; Bejui-Hugues J; Berry DJ; An KN
    Clin Orthop Relat Res; 2007 Feb; 455():202-8. PubMed ID: 17279045
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of the femoral offset and the head size on the safe range of motion in total hip arthroplasty.
    Matsushita A; Nakashima Y; Jingushi S; Yamamoto T; Kuraoka A; Iwamoto Y
    J Arthroplasty; 2009 Jun; 24(4):646-51. PubMed ID: 18534445
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Early primary total hip arthroplasty for acetabular fractures in elderly patients].
    Simko P; Braunsteiner T; Vajcziková S
    Acta Chir Orthop Traumatol Cech; 2006 Aug; 73(4):275-82. PubMed ID: 17026887
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Factors affecting the impingement angle of fixed- and mobile-bearing total knee replacements: a laboratory study.
    Walker PS; Yildirim G; Sussman-Fort J; Roth J; White B; Klein GR
    J Arthroplasty; 2007 Aug; 22(5):745-52. PubMed ID: 17689786
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Less range of motion with resurfacing arthroplasty than with total hip arthroplasty: in vitro examination of 8 designs.
    Bengs BC; Sangiorgio SN; Ebramzadeh E
    Acta Orthop; 2008 Dec; 79(6):755-62. PubMed ID: 19085491
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.