These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 9754098)

  • 1. Primary angiosarcoma of the pulmonary arteries: dynamic contrast-enhanced MRI.
    Kacl GM; Bruder E; Pfammatter T; Follath F; Salomon F; Debatin JF
    J Comput Assist Tomogr; 1998; 22(5):687-91. PubMed ID: 9754098
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulmonary MR angiography at 1.0 T: early results with k-space segmented and post-contrast TurboFLASH two-dimensional time-of-flight sequences.
    Laissy JP; Bancal C; Sekkal S; Chillon S; Berger JF; Limot O; Tebboune D; Henry-Feugeas MC; Falise B; Aubier M
    Eur J Radiol; 1995 May; 20(1):9-15. PubMed ID: 7556263
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Contrast-enhanced 3D MR angiography of the pulmonary arteries with integrated parallel acquisition technique (iPAT) in patients with chronic-thromboembolic pulmonary hypertension CTEPH - sagittal or coronal acquisition?].
    Oberholzer K; Romaneehsen B; Kunz P; Kramm T; Thelen M; Kreitner KF
    Rofo; 2004 Apr; 176(4):605-9. PubMed ID: 15088188
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Contrast media enhanced three dimensional MR angiography of the pulmonary arteries in patients with chronic recurrent pulmonary embolism--comparison with selective intra-arterial DSA].
    Kreitner KF; Ley S; Kauczor HU; Kalden P; Pitton MB; Mayer E; Laub G; Thelen M
    Rofo; 2000 Feb; 172(2):122-8. PubMed ID: 10723484
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent.
    Fink C; Ley S; Puderbach M; Plathow C; Bock M; Kauczor HU
    Eur Radiol; 2004 Jul; 14(7):1291-6. PubMed ID: 14997336
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Volumetric interpolated contrast-enhanced MRA for the diagnosis of pulmonary embolism in an ex vivo system.
    Biederer J; Liess C; Charalambous N; Heller M
    J Magn Reson Imaging; 2004 Apr; 19(4):428-37. PubMed ID: 15065166
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic breath-hold 3D gadolinium-enhanced MRI of intraarterial masses: findings in two patients.
    Krinsky G; Rofsky N; Sandler M; DeCorato D; Weinreb J
    J Comput Assist Tomogr; 1997; 21(4):631-4. PubMed ID: 9216773
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Gadolinium-enhanced 3D MRA of the aortic arch vessels in the detection of atherosclerotic cerebrovascular occlusive disease.
    Krinsky G; Maya M; Rofsky N; Lebowitz J; Nelson PK; Ambrosino M; Kaminer E; Earls J; Masters L; Giangola G; Litt A; Weinreb J
    J Comput Assist Tomogr; 1998; 22(2):167-78. PubMed ID: 9530375
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 3D breath-hold contrast-enhanced MRA: a preliminary experience in aorta and iliac vascular disease.
    Shetty AN; Shirkhoda A; Bis KG; Ellwood R; Li D
    J Comput Assist Tomogr; 1998; 22(2):179-85. PubMed ID: 9530376
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional contrast-enhanced magnetic resonance angiography of the thoracic vasculature.
    Leung DA; Debatin JF
    Eur Radiol; 1997; 7(7):981-9. PubMed ID: 9265659
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Chronic thromboembolic pulmonary hypertension: pre- and postoperative assessment with breath-hold MR imaging techniques.
    Kreitner KF; Ley S; Kauczor HU; Mayer E; Kramm T; Pitton MB; Krummenauer F; Thelen M
    Radiology; 2004 Aug; 232(2):535-43. PubMed ID: 15215554
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gadolinium-enhanced pulmonary magnetic resonance angiography in the diagnosis of acute pulmonary embolism: a prospective study on 48 patients.
    Pleszewski B; Chartrand-Lefebvre C; Qanadli SD; Déry R; Perreault P; Oliva VL; Prenovault J; Belblidia A; Soulez G
    Clin Imaging; 2006; 30(3):166-72. PubMed ID: 16632150
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulmonary hemorrhage: imaging with a new magnetic resonance blood pool agent in conjunction with breathheld three-dimensional magnetic resonance angiography.
    Weishaupt D; Hilfiker PR; Schmidt M; Debatin JF
    Cardiovasc Intervent Radiol; 1999; 22(4):321-5. PubMed ID: 10415223
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs.
    Abolmaali ND; Hietschold V; Appold S; Ebert W; Vogl TJ
    Eur Radiol; 2002 Mar; 12(3):692-7. PubMed ID: 11870489
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiosurgery for cerebral arteriovenous malformations: assessment of early phase magnetic resonance imaging and significance of gadolinium-DTPA enhancement.
    Morikawa M; Numaguchi Y; Rigamonti D; Kuroiwa T; Rothman MI; Zoarski GH; Simard JM; Eisenberg H; Amin PP
    Int J Radiat Oncol Biol Phys; 1996 Feb; 34(3):663-75. PubMed ID: 8621291
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Magnetic resonance angiography with contrast media in the study of carotid arteries].
    Catalano C; Laghi A; Pediconi F; Fraioli F; Napoli A; Passariello R
    Radiol Med; 2001; 101(1-2):54-9. PubMed ID: 11360754
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries.
    Holland GA; Dougherty L; Carpenter JP; Golden MA; Gilfeather M; Slossman F; Schnall MD; Axel L
    AJR Am J Roentgenol; 1996 Apr; 166(4):971-81. PubMed ID: 8610584
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulmonary time-of-flight MR angiography at 1.0 T: comparison between 2D and 3D tone acquisitions.
    Laissy JP; Assayag P; Henry-Feugeas MC; Tebboune D; Berger JF; Limot O; Falise B; Chillon S; Valere PE; Schouman-Claeys E
    Magn Reson Imaging; 1995; 13(7):949-57. PubMed ID: 8583873
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Whole-body magnetic resonance angiography using a contrast medium. Technical optimization].
    Carriero A; Scarabino T; Magarelli N; Giannatempo G; Vizzani F; Cammisa M; Salvolini U; Bonomo L
    Radiol Med; 1997 Oct; 94(4):319-24. PubMed ID: 9465237
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Magnetic resonance angiography of the vessels of the neck: the optimization of a dynamic technic during the rapid infusion of a paramagnetic contrast medium].
    Scarabino T; Carriero A; Giannatempo GM; Simeone A; Armillotta M; Bonomo L; Salvolini U
    Radiol Med; 1997 Oct; 94(4):325-8. PubMed ID: 9465238
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.