These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 9754181)

  • 1. Characteristics of glaucoma drainage implants during dynamic and steady-state flow conditions.
    Francis BA; Cortes A; Chen J; Alvarado JA
    Ophthalmology; 1998 Sep; 105(9):1708-14. PubMed ID: 9754181
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro and in vivo flow characteristics of glaucoma drainage implants.
    Prata JA; Mérmoud A; LaBree L; Minckler DS
    Ophthalmology; 1995 Jun; 102(6):894-904. PubMed ID: 7777296
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro flow properties of glaucoma implant devices.
    Eisenberg DL; Koo EY; Hafner G; Schuman JS
    Ophthalmic Surg Lasers; 1999; 30(8):662-7. PubMed ID: 10507569
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro flow characteristics of the Ahmed and self-constructed anterior chamber shunts.
    Strubbe DT; Gelatt KN; MacKay EO
    Am J Vet Res; 1997 Nov; 58(11):1332-7. PubMed ID: 9361902
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of closing pressure in silicone Ahmed FP7 glaucoma valves.
    Moss EB; Trope GE
    J Glaucoma; 2008 Sep; 17(6):489-93. PubMed ID: 18794686
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of safety and efficacy between silicone and polypropylene Ahmed glaucoma valves in refractory glaucoma.
    Law SK; Nguyen A; Coleman AL; Caprioli J
    Ophthalmology; 2005 Sep; 112(9):1514-20. PubMed ID: 16005977
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of the Ahmed S2 glaucoma valve compared with the Baerveldt 250-mm2 glaucoma implant.
    Goulet RJ; Phan AD; Cantor LB; WuDunn D
    Ophthalmology; 2008 Jul; 115(7):1141-7. PubMed ID: 18164068
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modification of the glaucoma drainage implant to prevent early postoperative hypertension and hypotony: a laboratory study.
    Brooks SE; Dacey MP; Lee MB; Baerveldt G
    Ophthalmic Surg; 1994 May; 25(5):311-6. PubMed ID: 8058263
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma.
    Ayyala RS; Zurakowski D; Smith JA; Monshizadeh R; Netland PA; Richards DW; Layden WE
    Ophthalmology; 1998 Oct; 105(10):1968-76. PubMed ID: 9787371
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy and safety of adjunctive mitomycin C during Ahmed Glaucoma Valve implantation: a prospective randomized clinical trial.
    Costa VP; Azuara-Blanco A; Netland PA; Lesk MR; Arcieri ES
    Ophthalmology; 2004 Jun; 111(6):1071-6. PubMed ID: 15177955
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hemodynamic and respiratory effects of negative tracheal pressure during CPR in pigs.
    Yannopoulos D; Aufderheide TP; McKnite S; Kotsifas K; Charris R; Nadkarni V; Lurie KG
    Resuscitation; 2006 Jun; 69(3):487-94. PubMed ID: 16678959
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface area of glaucoma implants and perfusion flow rates in rabbit eyes.
    Prata JA; Santos RC; Labree L; Minckler DS
    J Glaucoma; 1995 Aug; 4(4):274-80. PubMed ID: 19920686
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma II: longer-term outcomes from a single surgeon.
    Tsai JC; Johnson CC; Kammer JA; Dietrich MS
    Ophthalmology; 2006 Jun; 113(6):913-7. PubMed ID: 16751034
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a single-surgeon comparison of outcome.
    Tsai JC; Johnson CC; Dietrich MS
    Ophthalmology; 2003 Sep; 110(9):1814-21. PubMed ID: 13129882
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Management of uveitic glaucoma with Ahmed glaucoma valve implantation.
    Da Mata A; Burk SE; Netland PA; Baltatzis S; Christen W; Foster CS
    Ophthalmology; 1999 Nov; 106(11):2168-72. PubMed ID: 10571354
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of polypropylene and silicone Ahmed Glaucoma Valves.
    Ishida K; Netland PA; Costa VP; Shiroma L; Khan B; Ahmed II
    Ophthalmology; 2006 Aug; 113(8):1320-6. PubMed ID: 16877071
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thin-film coupled fluid-solid analysis of flow through the Ahmed glaucoma drainage device.
    Stay MS; Pan T; Brown JD; Ziaie B; Barocas VH
    J Biomech Eng; 2005 Oct; 127(5):776-81. PubMed ID: 16248307
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterisation and simulation of an active microvalve for glaucoma.
    Sassetti F; Guarnieri FA; Garelli L; Storti MA
    Comput Methods Biomech Biomed Engin; 2012; 15(12):1273-80. PubMed ID: 21809942
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative in vitro flow study of 3 different Ex-PRESS miniature glaucoma device models.
    Estermann S; Yuttitham K; Chen JA; Lee OT; Stamper RL
    J Glaucoma; 2013 Mar; 22(3):209-14. PubMed ID: 22274666
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Superior versus inferior Ahmed glaucoma valve implantation.
    Pakravan M; Yazdani S; Shahabi C; Yaseri M
    Ophthalmology; 2009 Feb; 116(2):208-13. PubMed ID: 19062098
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.