These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 9761254)

  • 1. CO-oximetry interference by perflubron emulsion: comparison of hemolyzing and nonhemolyzing instruments.
    Shepherd AP; Steinke JM
    Clin Chem; 1998 Oct; 44(10):2183-90. PubMed ID: 9761254
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Co-oximetry interference by hemoglobin-based blood substitutes.
    Ali AA; Ali GS; Steinke JM; Shepherd AP
    Anesth Analg; 2001 Apr; 92(4):863-9. PubMed ID: 11273915
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of two oximeters for use in cardiac catheterization laboratories.
    Freeman GL; Steinke JM
    Cathet Cardiovasc Diagn; 1993 Sep; 30(1):51-7. PubMed ID: 8402867
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of carboxyhemoglobin and total hemoglobin by five specialized spectrophotometers (CO-oximeters) in comparison with reference methods.
    Mahoney JJ; Vreman HJ; Stevenson DK; Van Kessel AL
    Clin Chem; 1993 Aug; 39(8):1693-700. PubMed ID: 8353959
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The effect of hyperbilirubinemia on the measurement of oxygenated hemoglobin (O2Hb), carboxyhemoglobin (COHb) and methemoglobin (MetHb) using multiwavelength oximeters in mixed venous blood].
    Lampert R; Brandt L
    Anaesthesist; 1993 Oct; 42(10):702-9. PubMed ID: 8250204
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of pulse oximetry during hypoxemia.
    Thrush D; Hodges MR
    South Med J; 1994 Apr; 87(4):518-21. PubMed ID: 8153783
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin.
    Zijlstra WG; Buursma A; Meeuwsen-van der Roest WP
    Clin Chem; 1991 Sep; 37(9):1633-8. PubMed ID: 1716537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of turbidity-correction algorithm eliminates the effect of perflubron emulsion on CO-oximeter results.
    Toffaletti JG; Wildermann RF
    Clin Chem; 2000 Jan; 46(1):136-7. PubMed ID: 10620590
    [No Abstract]   [Full Text] [Related]  

  • 9. Evaluation of the AVOXimeter: precision, long-term stability, linearity, and use without heparin.
    Bailey SR; Russell EL; Martinez A
    J Clin Monit; 1997 May; 13(3):191-8. PubMed ID: 9234088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.
    Barker SJ; Curry J; Redford D; Morgan S
    Anesthesiology; 2006 Nov; 105(5):892-7. PubMed ID: 17065881
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The measurement of dyshemoglobins and total hemoglobin by pulse oximetry.
    Barker SJ; Badal JJ
    Curr Opin Anaesthesiol; 2008 Dec; 21(6):805-10. PubMed ID: 18997533
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Carboxyhemoglobin as measured by gas chromatography and with the IL 282 and 482 CO-Oximeters.
    Vreman HJ; Mahoney JJ; Van Kessel AL; Stevenson DK
    Clin Chem; 1988 Dec; 34(12):2562-6. PubMed ID: 3197302
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Carboxyhemoglobin determined in neonatal blood with a CO-oximeter unaffected by fetal oxyhemoglobin.
    Vreman HJ; Stevenson DK
    Clin Chem; 1994 Aug; 40(8):1522-7. PubMed ID: 7519133
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new instrument for the simultaneous measurement of total hemoglobin, % oxyhemoglobin, % carboxyhemoglobin, % methemoglobin, and oxygen content in whole blood.
    Brown LJ
    IEEE Trans Biomed Eng; 1980 Mar; 27(3):132-8. PubMed ID: 7358415
    [No Abstract]   [Full Text] [Related]  

  • 16. Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.
    Nijland R; Jongsma HW; Nijhuis JG; Oeseburg B; Zijlstra WG
    Acta Anaesthesiol Scand Suppl; 1995; 107():49-52. PubMed ID: 8599297
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Oximeters.
    Golish JA; McCarthy K
    Chest; 1988 Nov; 94(5):1110-2. PubMed ID: 3180869
    [No Abstract]   [Full Text] [Related]  

  • 18. Effect of carboxyhemoglobin on the accuracy of mixed venous oximetry monitors in dogs.
    Haney M; Tait AR; Tremper KK
    Crit Care Med; 1994 Jul; 22(7):1181-5. PubMed ID: 8026210
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of recorded values from six pulse oximeters.
    Choe H; Tashiro C; Fukumitsu K; Yagi M; Yoshiya I
    Crit Care Med; 1989 Jul; 17(7):678-81. PubMed ID: 2736930
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inaccurate pulse CO-oximetry of carboxyhemoglobin due to digital clubbing: case report.
    Harlan N; Weaver LK; Deru K
    Undersea Hyperb Med; 2016; 43(1):59-61. PubMed ID: 27000014
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.