  • 1. A comparison of three modes of ventilation with the use of an adult circle system in an infant lung model.
    Tobin MJ; Stevenson GW; Horn BJ; Chen EH; Hall SC; Coté CJ
    Anesth Analg; 1998 Oct; 87(4):766-71. PubMed ID: 9768767
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pressure-limited ventilation of infants with low-compliance lungs: the efficacy of an adult circle system versus two free-standing intensive care unit ventilator systems using an in vitro model.
    Stevenson GW; Horn B; Tobin M; Chen EH; Sautel M; Hall SC; Coté CJ
    Anesth Analg; 1999 Sep; 89(3):638-41. PubMed ID: 10475294
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of circuit compliance on delivered ventilation with use of an adult circle system for time cycled volume controlled ventilation using an infant lung model.
    Stevenson GW; Tobin MJ; Horn BJ; Sautel M; Chen EH; Hall SC; Coté CJ
    Paediatr Anaesth; 1998; 8(2):139-44. PubMed ID: 9549741
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An adult system versus a Bain system: comparative ability to deliver minute ventilation to an infant lung model with pressure-limited ventilation.
    Stevenson GW; Tobin M; Horn B; Chen EH; Hall SC; Coté CJ
    Anesth Analg; 1999 Mar; 88(3):527-30. PubMed ID: 10071999
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pressure control ventilation: three anesthesia ventilators compared using an infant lung model.
    Stayer SA; Bent ST; Skjonsby BS; Frolov A; Andropoulos DB
    Anesth Analg; 2000 Nov; 91(5):1145-50. PubMed ID: 11049900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of rate and inspiratory flow on ventilator-induced lung injury.
    Rich PB; Reickert CA; Sawada S; Awad SS; Lynch WR; Johnson KJ; Hirschl RB
    J Trauma; 2000 Nov; 49(5):903-11. PubMed ID: 11086784
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
    Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
    Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.
    Hentschel R; Buntzel J; Guttmann J; Schumann S
    Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of endotracheal tube size and ventilator settings on the mechanics of a test system during intermittent flow ventilation.
    Farstad T; Bratlid D
    Pediatr Pulmonol; 1991; 11(1):15-21. PubMed ID: 1923663
    [TBL] [Abstract][Full Text] [Related]  

  • 12. How to ventilate preterm infants with lung compliance close to circuit compliance: real-time simulations on an infant hybrid respiratory simulator.
    Stankiewicz B; Pałko KJ; Darowski M; Kozarski M
    Med Biol Eng Comput; 2020 Feb; 58(2):357-372. PubMed ID: 31853776
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The effect of changes in lung compliance on ventilation in newborns. Results of animal experiments with two different respirators].
    Schirmer U; Schreiber M; Goertz A; Schütz W; Rockemann M; Georgieff M
    Anaesthesist; 1994 Aug; 43(8):521-7. PubMed ID: 7978175
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support.
    Fujino Y; Uchiyama A; Mashimo T; Nishimura M
    Respir Care; 2003 Jan; 48(1):38-45. PubMed ID: 12556260
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tracheal gas insufflation-pressure control versus volume control ventilation. A lung model study.
    Imanaka H; Kacmarek RM; Ritz R; Hess D
    Am J Respir Crit Care Med; 1996 Mar; 153(3):1019-24. PubMed ID: 8630540
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of Endotracheal Tube Size, Respiratory System Mechanics, and Ventilator Settings on Driving Pressure.
    Ilia S; van Schelven PD; Koopman AA; Blokpoel RGT; de Jager P; Burgerhof JGM; Markhorst DG; Kneyber MCJ
    Pediatr Crit Care Med; 2020 Jan; 21(1):e47-e51. PubMed ID: 31688716
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief?
    Maeda Y; Fujino Y; Uchiyama A; Taenaka N; Mashimo T; Nishimura M
    Crit Care; 2003 Oct; 7(5):R92-7. PubMed ID: 12974975
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.
    Ivanov VA
    Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Using conventional infant ventilators at unconventional rates.
    Boros SJ; Bing DR; Mammel MC; Hagen E; Gordon MJ
    Pediatrics; 1984 Oct; 74(4):487-92. PubMed ID: 6384912
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Albuterol delivery from a metered-dose inhaler with spacer is reduced following short-duration manual ventilation in a neonatal ventilator-lung model.
    Lugo RA; Ballard J
    Respir Care; 2004 Sep; 49(9):1029-34. PubMed ID: 15329174
    [TBL] [Abstract][Full Text] [Related]  