154 related articles for article (PubMed ID: 9769697)
1. In vitro simulation of contact fatigue damage found in ultra-high molecular weight polyethylene components of knee prostheses.
Currier JH; Duda JL; Sperling DK; Collier JP; Currier BH; Kennedy FE
Proc Inst Mech Eng H; 1998; 212(4):293-302. PubMed ID: 9769697
[TBL] [Abstract][Full Text] [Related]
2. Micro-wear patterns on UHMWPE tibial inserts in total knee joint simulation.
Tamura J; Clarke IC; Kawanabe K; Akagi M; Good VD; Williams PA; Masaoka T; Schroeder D; Oonishi H
J Biomed Mater Res; 2002 Aug; 61(2):218-25. PubMed ID: 12007202
[TBL] [Abstract][Full Text] [Related]
3. Wear, delamination, and fatigue resistance of melt-annealed highly crosslinked UHMWPE cruciate-retaining knee inserts under activities of daily living.
Popoola OO; Yao JQ; Johnson TS; Blanchard CR
J Orthop Res; 2010 Sep; 28(9):1120-6. PubMed ID: 20162713
[TBL] [Abstract][Full Text] [Related]
4. The impact of sterilization method on wear in knee arthroplasty.
Williams IR; Mayor MB; Collier JP
Clin Orthop Relat Res; 1998 Nov; (356):170-80. PubMed ID: 9917682
[TBL] [Abstract][Full Text] [Related]
5. An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact.
Ohashi M; Tomita N; Ikada Y; Ikeuchi K; Motoike T
Biomed Mater Eng; 1996; 6(6):441-51. PubMed ID: 9138654
[TBL] [Abstract][Full Text] [Related]
6. Gamma-irradiation sterilization in an inert environment: a partial solution.
Berry DJ; Currier BH; Mayor MB; Collier JP
Clin Orthop Relat Res; 2012 Jul; 470(7):1805-13. PubMed ID: 22033874
[TBL] [Abstract][Full Text] [Related]
7. Comparison of gas plasma and gamma irradiation in air sterilization on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacements.
Reeves EA; Barton DC; FitzPatrick DP; Fisher J
Proc Inst Mech Eng H; 2000; 214(3):249-55. PubMed ID: 10902439
[TBL] [Abstract][Full Text] [Related]
8. Fractography and oxidative analysis of gamma inert sterilized posterior-stabilized tibial insert post fractures: report of two cases.
Ansari F; Chang J; Huddleston J; Van Citters D; Ries M; Pruitt L
Knee; 2013 Dec; 20(6):609-13. PubMed ID: 24220187
[TBL] [Abstract][Full Text] [Related]
9. Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components.
Watanabe E; Suzuki M; Nagata K; Kaneeda T; Harada Y; Utsumi M; Mori A; Moriya H
J Biomed Mater Res; 2002 Dec; 62(4):540-9. PubMed ID: 12221702
[TBL] [Abstract][Full Text] [Related]
10. In vivo oxidation of gamma-barrier-sterilized ultra-high-molecular-weight polyethylene bearings.
Currier BH; Currier JH; Mayor MB; Lyford KA; Van Citters DW; Collier JP
J Arthroplasty; 2007 Aug; 22(5):721-31. PubMed ID: 17689783
[TBL] [Abstract][Full Text] [Related]
11. Elasto-plastic contact analysis of an ultra-high molecular weight polyethylene tibial component based on geometrical measurement from a retrieved knee prosthesis.
Cho CH; Murakami T; Sawae Y; Sakai N; Miura H; Kawano T; Iwamoto Y
Proc Inst Mech Eng H; 2004; 218(4):251-9. PubMed ID: 15376727
[TBL] [Abstract][Full Text] [Related]
12. Analysis of severely fractured glenoid components: clinical consequences of biomechanics, design, and materials selection on implant performance.
Ansari F; Lee T; Malito L; Martin A; Gunther SB; Harmsen S; Norris TR; Ries M; Van Citters D; Pruitt L
J Shoulder Elbow Surg; 2016 Jul; 25(7):1041-50. PubMed ID: 26775748
[TBL] [Abstract][Full Text] [Related]
13. Detection of cracks in polyethylene components of retrieved knee joint prostheses.
Koizumi M; Tomita N; Tamai S; Oonishi H; Ikada Y
J Orthop Sci; 1998; 3(6):330-5. PubMed ID: 9811985
[TBL] [Abstract][Full Text] [Related]
14. Effect of e-beam sterilization on the in vivo performance of conventional UHMWPE tibial plates for total knee arthroplasty.
Tone S; Hasegawa M; Pezzotti G; Puppulin L; Sudo A
Acta Biomater; 2017 Jun; 55():455-465. PubMed ID: 28359857
[TBL] [Abstract][Full Text] [Related]
15. Radiographic assessment of the thickness lost from polyethylene tibial inserts that had been sterilized differently.
Collier MB; Engh CA; Hatten KM; Ginn SD; Sheils TM; Engh GA
J Bone Joint Surg Am; 2008 Jul; 90(7):1543-52. PubMed ID: 18594104
[TBL] [Abstract][Full Text] [Related]
16. A highly crosslinked UHMWPE for CR and PS total knee arthroplasties.
Wang A; Yau SS; Essner A; Herrera L; Manley M; Dumbleton J
J Arthroplasty; 2008 Jun; 23(4):559-66. PubMed ID: 18514875
[TBL] [Abstract][Full Text] [Related]
17. Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator.
Benson LC; DesJardins JD; Harman MK; LaBerge M
Proc Inst Mech Eng H; 2002; 216(6):409-18. PubMed ID: 12502005
[TBL] [Abstract][Full Text] [Related]
18. The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements.
Maiti R; Cowie RM; Fisher J; Jennings LM
Proc Inst Mech Eng H; 2017 Jul; 231(7):634-642. PubMed ID: 28661229
[TBL] [Abstract][Full Text] [Related]
19. Gamma inert sterilization: a solution to polyethylene oxidation?
Medel FJ; Kurtz SM; Hozack WJ; Parvizi J; Purtill JJ; Sharkey PF; MacDonald D; Kraay MJ; Goldberg V; Rimnac CM
J Bone Joint Surg Am; 2009 Apr; 91(4):839-49. PubMed ID: 19339568
[TBL] [Abstract][Full Text] [Related]
20. Impact of gamma sterilization on clinical performance of polyethylene in the knee.
Collier JP; Sperling DK; Currier JH; Sutula LC; Saum KA; Mayor MB
J Arthroplasty; 1996 Jun; 11(4):377-89. PubMed ID: 8792243
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]