These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 9773689)

  • 61. A comparative analysis of internal bone remodelling concepts in a novel implant for direct skeletal attachment of limb prosthesis evaluation: A finite element analysis.
    Prochor P; Sajewicz E
    Proc Inst Mech Eng H; 2018 Mar; 232(3):289-298. PubMed ID: 29350089
    [TBL] [Abstract][Full Text] [Related]  

  • 62. The effect of implant thread design on stress distribution in anisotropic bone with different osseointegration conditions: a finite element analysis.
    Mosavar A; Ziaei A; Kadkhodaei M
    Int J Oral Maxillofac Implants; 2015; 30(6):1317-26. PubMed ID: 26478976
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method.
    Jamaludin MS; Hanafusa A; Shinichirou Y; Agarie Y; Otsuka H; Ohnishi K
    Bioengineering (Basel); 2019 Oct; 6(4):. PubMed ID: 31652967
    [TBL] [Abstract][Full Text] [Related]  

  • 64. An Efficient Modelling-Simulation-Analysis Workflow to Investigate Stump-Socket Interaction Using Patient-Specific, Three-Dimensional, Continuum-Mechanical, Finite Element Residual Limb Models.
    Ramasamy E; Avci O; Dorow B; Chong SY; Gizzi L; Steidle G; Schick F; Röhrle O
    Front Bioeng Biotechnol; 2018; 6():126. PubMed ID: 30283777
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Potential of modeling and simulations of bioengineered devices: Endoprostheses, prostheses and orthoses.
    Ginestra PS; Ceretti E; Fiorentino A
    Proc Inst Mech Eng H; 2016 Jul; 230(7):607-38. PubMed ID: 27095509
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Parametric optimization and design validation based on finite element analysis of hybrid socket adapter for transfemoral prosthetic knee.
    Kumar N
    Prosthet Orthot Int; 2014 Oct; 38(5):363-8. PubMed ID: 24286805
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Analyse of socket-prosthesis-blunt complex for lower limb amputee using objective measure of patient's gait cycle.
    Rotariu M; Filep R; Turnea M; Ilea M; Arotăriţei D; Popescu M
    Rev Med Chir Soc Med Nat Iasi; 2015; 119(1):281-6. PubMed ID: 25970979
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Design of monolimb using finite element modelling and statistics-based Taguchi method.
    Lee WC; Zhang M
    Clin Biomech (Bristol, Avon); 2005 Aug; 20(7):759-66. PubMed ID: 15963612
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Transfemoral socket design and suspension options.
    Kapp SL
    Phys Med Rehabil Clin N Am; 2000 Aug; 11(3):569-83, vi. PubMed ID: 10989479
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Below knee prosthetic socket designs and suspension systems.
    Edwards ML
    Phys Med Rehabil Clin N Am; 2000 Aug; 11(3):585-93, vi. PubMed ID: 10989480
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Characteristics of a volume-adjustable compression chamber for transradial prosthetic interface.
    Sang Y; Li X; Luo Y
    Proc Inst Mech Eng H; 2016 Jul; 230(7):650-60. PubMed ID: 27146289
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Virtual simulation of an osseointegrated trans-humeral prosthesis: A falling scenario.
    Mirulla AI; Bragonzoni L; Zaffagnini S; Bontempi M; Nigrelli V; Ingrassia T
    Injury; 2018 Apr; 49(4):784-791. PubMed ID: 29530511
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Review of research on prosthetic devices for lower extremity amputation.
    Collins DM; Karmarkar A; Relich R; Pasquina PF; Cooper RA
    Crit Rev Biomed Eng; 2006; 34(5):379-438. PubMed ID: 17206920
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Comfort level discussion for prosthetic sockets with different fabricating processing conditions.
    Hsu CH; Ou CH; Hong WL; Gao YH
    Biomed Eng Online; 2018 Nov; 17(Suppl 2):145. PubMed ID: 30396348
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Influence of the geometry of a ball-and-socket intervertebral prosthesis at the cervical spine: a finite element study.
    Rousseau MA; Bonnet X; Skalli W
    Spine (Phila Pa 1976); 2008 Jan; 33(1):E10-4. PubMed ID: 18165735
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Using mechanical testing to assess the effect of lower-limb prosthetic socket texturing on longitudinal suspension.
    Quinlan J; Yohay J; Subramanian V; Poziembo B; Fatone S
    PLoS One; 2020; 15(8):e0237841. PubMed ID: 32813733
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Effective elastic properties for lower limb soft tissues from manual indentation experiment.
    Zheng Y; Mak AF
    IEEE Trans Rehabil Eng; 1999 Sep; 7(3):257-67. PubMed ID: 10498372
    [TBL] [Abstract][Full Text] [Related]  

  • 78. An investigation on effects of amputee's physiological parameters on maximum pressure developed at the prosthetic socket interface using artificial neural network.
    Nayak C; Singh A; Chaudhary H; Unune DR
    Technol Health Care; 2017 Oct; 25(5):969-979. PubMed ID: 28854522
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Biomechanical evaluation of screw- and cement-retained implant-supported prostheses: a nonlinear finite element analysis.
    Silva GC; Cornacchia TM; de Magalhães CS; Bueno AC; Moreira AN
    J Prosthet Dent; 2014 Dec; 112(6):1479-88. PubMed ID: 25062583
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Strength testing of low-cost 3D-printed transtibial prosthetic socket.
    van der Stelt M; Verhamme L; Slump CH; Brouwers L; Maal TJ
    Proc Inst Mech Eng H; 2022 Mar; 236(3):367-375. PubMed ID: 34852701
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.