These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 97758)

  • 1. [Detection of irregular alloantibodies by Groupamatic using a trypsin-polybrene-citrate technic].
    Confida S; Hurel C; Muller A; Garretta M
    Rev Fr Transfus Immunohematol; 1978 Mar; 21(2):457-72. PubMed ID: 97758
    [No Abstract]   [Full Text] [Related]  

  • 2. Red blood cell antibody screening with groupamatic system. II. A two-step haemagglutination technique using a trypsin-polybren-citrate method.
    Confida S; Hurel C; Chesnel N; Garretta M; Muller A
    Vox Sang; 1981 Jan; 40(1):34-43. PubMed ID: 7222562
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The manual polybrene test: a simple and rapid procedure for detection of red cell antibodies.
    Lalezari P; Jiang AF
    Transfusion; 1980; 20(2):206-11. PubMed ID: 6768173
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A proposal for compatibility testing incorporating the manual hexadimethrine bromide (Polybrene) test.
    Steane EA; Steane SM; Montgomery SR; Pearson JR
    Transfusion; 1985; 25(6):540-4. PubMed ID: 4071598
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of Duffy and Kidd antibodies by Groupamatic 360.
    Rubinstein P; Walker ME; Allen FH
    Rev Fr Transfus Immunohematol; 1978 Mar; 21(2):451-5. PubMed ID: 675001
    [No Abstract]   [Full Text] [Related]  

  • 6. Anti-Jka, -C, and -E in a single patient, initially demonstrable only by the manual hexadimethrine bromide (Polybrene) test, with incompatibilities confirmed by 51Cr-labeled red cell studies.
    Maynard BA; Smith DS; Farrar RP; Kraetsch RE; Chaplin H
    Transfusion; 1988; 28(4):302-6. PubMed ID: 3133842
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemolytic anti-hr" (e) detectable solely by an automated polybrene technique.
    Snyder EL; Spivack M; Novodoff D; Kling G
    Transfusion; 1978; 18(1):79-83. PubMed ID: 415394
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of a commercial hexadimethrine bromide method and low-ionic-strength solution for antibody detection with special reference to anti-K.
    Letendre PL; Williams MA; Ferguson DJ
    Transfusion; 1987; 27(2):138-41. PubMed ID: 3103267
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Automated screening and identification of irregular anti-erythrocyte antibodies].
    Wattar B; Govaerts A
    Rev Fr Transfus Immunohematol; 1982 Jun; 25(3):297-308. PubMed ID: 6810440
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Polybrene technique for red cell antibody screening using microplates.
    Lown JA; Ivey JG
    J Clin Pathol; 1988 May; 41(5):556-7. PubMed ID: 3290265
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Some factors, influencing the sensitivity of the antibody screening the Groupamatic 360 system.
    Messeter L
    Rev Fr Transfus Immunohematol; 1978 Mar; 21(2):485-94. PubMed ID: 97759
    [No Abstract]   [Full Text] [Related]  

  • 12. Lack of clinical significance of "enzyme-only" red cell alloantibodies.
    Issitt PD; Combs MR; Bredehoeft SJ; Campbell ML; Heimer M; Joyner L; Lorentsen L; Remley C; Bullock S; Bumgarner J
    Transfusion; 1993 Apr; 33(4):284-93. PubMed ID: 8480348
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automated red cell antibody detection. An improved method.
    Dawes BJ; Goldsmith KL
    Vox Sang; 1975; 29(4):248-52. PubMed ID: 1146281
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of IgG subclasses on automated anti-D (Rho) quantification.
    Boudart D; Rivat-Peran L; Brossard Y; Lopes P; Yviquel M
    Vox Sang; 1984; 47(5):373-8. PubMed ID: 6209856
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Blood group alloantibodies: an assessment of some laboratory practices.
    Giblett ER
    Transfusion; 1977; 17(4):299-308. PubMed ID: 406699
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automated reading of red cell antibody identification tests by a solid phase antiglobulin technique.
    Moore HH
    Transfusion; 1984; 24(3):218-21. PubMed ID: 6427989
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rh, Kell, Duffy, Kidd and Diego blood group system polymorphism in Brazilian Japanese descendants.
    FlĂ´res MA; Visentainer JE; Guelsin GA; Fracasso Ade S; de Melo FC; Hashimoto MN; Sell AM
    Transfus Apher Sci; 2014 Feb; 50(1):123-8. PubMed ID: 24231689
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Red cell antibody screening with the Groupamatic system. I. Bromelin methyl-cellulose and saline techniques: evaluation of five years' routine use.
    Garretta M; Gener J; de Jerphanion I; Jacquet D; Muller A
    Vox Sang; 1979; 37(1):55-61. PubMed ID: 115156
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Erythrocyte antigens on human platelets. Absence of Rh, Duffy, Kell, Kidd, and Lutheran antigens.
    Dunstan RA; Simpson MB; Rosse WF
    Transfusion; 1984; 24(3):243-6. PubMed ID: 6427991
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Letter Concerning: "Genotyping for Kidd, Kell, Duffy, Scianna, and RHCE Blood Group Antigens Polymorphisms in Jiangsu Chinese Han".
    Colli CM; Quirino MG; Sell AM; Visentainer JE
    Chin Med J (Engl); 2015 Jun; 128(12):1704. PubMed ID: 26063381
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.