These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
106 related articles for article (PubMed ID: 9778069)
1. Comparison of oversensing during bradycardia pacing in two types of implantable cardioverter-defibrillator systems. Mann DE; Damle RS; Kelly PA; Landers M; Otto L; Reiter MJ Am Heart J; 1998 Oct; 136(4 Pt 1):658-63. PubMed ID: 9778069 [TBL] [Abstract][Full Text] [Related]
2. Oversensing during ventricular pacing in patients with a third-generation implantable cardioverter-defibrillator. Kelly PA; Mann DE; Damle RS; Reiter MJ J Am Coll Cardiol; 1994 Jun; 23(7):1531-4. PubMed ID: 8195509 [TBL] [Abstract][Full Text] [Related]
3. Paced beats following single nonsensed complexes in a "codependent" cardioverter defibrillator and bradycardia pacing system: potential for ventricular tachycardia induction. Callans DJ; Hook BG; Marchlinski FE Pacing Clin Electrophysiol; 1991 Aug; 14(8):1281-7. PubMed ID: 1719506 [TBL] [Abstract][Full Text] [Related]
4. Effect of sensing system on the incidence of myopotential oversensing during bradycardia pacing in implantable cardioverter-defibrillators. Mann DE; Otto L; Kelly PA; Reiter MJ Am J Cardiol; 2000 Jun; 85(11):1380-2. PubMed ID: 10831961 [No Abstract] [Full Text] [Related]
5. Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing. Welte N; Strik M; Eschalier R; Mondoly P; Defaye P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Koneru J; Ellenbogen KA; Bordachar P Heart Rhythm; 2017 Jul; 14(7):1008-1015. PubMed ID: 28323174 [TBL] [Abstract][Full Text] [Related]
7. Inhibition of bradycardia pacing caused by far-field atrial sensing in a third-generation cardioverter defibrillator with an automatic gain feature. Curwin JH; Roelke M; Ruskin JN Pacing Clin Electrophysiol; 1996 Jan; 19(1):124-6. PubMed ID: 8848369 [TBL] [Abstract][Full Text] [Related]
16. Impact of pacing and high-pass filter settings on ventricular bipolar electrograms in implantable cardioverter defibrillator systems. - Implication of predictors for inappropriate therapy caused by oversensing of repolarization electrograms-. Maesato A; Higa S; Lin YJ; Chinen I; Ishigaki S; Yajima M; Masuzaki H; Chen SA Circ J; 2011; 75(9):2095-104. PubMed ID: 21757820 [TBL] [Abstract][Full Text] [Related]
17. T wave oversensing and low percentage of biventricular pacing in cardiac resynchronization therapy. Lezcano AO; Aracama JM; Ayestaran VU; Urra FG Cardiol J; 2009; 16(6):580-1. PubMed ID: 19950098 [TBL] [Abstract][Full Text] [Related]
18. Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrogram width criterion. Duru F; Bauersfeld U; Candinas R Europace; 2001 Jan; 3(1):80-4. PubMed ID: 11271957 [TBL] [Abstract][Full Text] [Related]
19. Heart rate, pacing, and outcome in the Dual Chamber and VVI Implantable Defibrillator (DAVID) trials. Kudenchuk PJ; Hallstrom AP; Herre JM; Wilkoff BL; Heart Rhythm; 2009 Aug; 6(8):1129-35. PubMed ID: 19632624 [TBL] [Abstract][Full Text] [Related]