These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

262 related articles for article (PubMed ID: 9779140)

  • 1. Clinical evaluation of the Codman microsensor intracranial pressure monitoring system.
    Fernandes HM; Bingham K; Chambers IR; Mendelow AD
    Acta Neurochir Suppl; 1998; 71():44-6. PubMed ID: 9779140
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A clinical evaluation of the Codman MicroSensor for intracranial pressure monitoring.
    Signorini DF; Shad A; Piper IR; Statham PF
    Br J Neurosurg; 1998 Jun; 12(3):223-7. PubMed ID: 11013684
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of zero drift in the Codman intracranial pressure monitor: a study from 2 neurointensive care units.
    Al-Tamimi YZ; Helmy A; Bavetta S; Price SJ
    Neurosurgery; 2009 Jan; 64(1):94-8; discussion 98-9. PubMed ID: 19145157
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Methods of experimental and clinical assessment of the relative measurement accuracy of an intracranial pressure transducer. Technical note.
    Morgalla MH; Krasznai L; Dietz K; Mettenleiter H; Deininger M; Grote EH
    J Neurosurg; 2001 Sep; 95(3):529-32. PubMed ID: 11565881
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Camino intracranial pressure device in clinical practice: reliability, handling characteristics and complications.
    Münch E; Weigel R; Schmiedek P; Schürer L
    Acta Neurochir (Wien); 1998; 140(11):1113-9; discussion 1119-20. PubMed ID: 9870055
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intracranial pressure and clinical status: assessment of two intracranial pressure transducers.
    Banister K; Chambers IR; Siddique MS; Femandes HM; Mendelow AD
    Physiol Meas; 2000 Nov; 21(4):473-9. PubMed ID: 11110245
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies.
    Piper I; Barnes A; Smith D; Dunn L
    Neurosurgery; 2001 Nov; 49(5):1158-64; discussion 1164-5. PubMed ID: 11846910
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a microsensor intracranial pressure transducer.
    Gopinath SP; Cherian L; Robertson CS; Narayan RK; Grossman RG
    J Neurosci Methods; 1993 Aug; 49(1-2):11-5. PubMed ID: 8271823
    [TBL] [Abstract][Full Text] [Related]  

  • 9. ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers.
    Morgalla MH; Mettenleiter H; Katzenberger T
    J Med Eng Technol; 1999; 23(1):10-4. PubMed ID: 10202697
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intracranial pressure monitoring in normal dogs using subdural and intraparenchymal miniature strain-gauge transducers.
    Sturges BK; Dickinson PJ; Tripp LD; Udaltsova I; LeCouteur RA
    J Vet Intern Med; 2019 Mar; 33(2):708-716. PubMed ID: 30575120
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A clinical study of parenchymal and subdural miniature strain-gauge transducers for monitoring intracranial pressure.
    Gray WP; Palmer JD; Gill J; Gardner M; Iannotti F
    Neurosurgery; 1996 Nov; 39(5):927-31; discussion 931-2. PubMed ID: 8905747
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of simultaneous continuous intracranial pressure (ICP) signals from a Codman and a Camino ICP sensor.
    Eide PK
    Med Eng Phys; 2006 Jul; 28(6):542-9. PubMed ID: 16253539
    [TBL] [Abstract][Full Text] [Related]  

  • 13. ICP measurement control: laboratory test of 7 types of intracranial pressure transducers.
    Morgalla MH; Mettenleiter H; Bitzer M; Fretschner R; Grote EH
    J Med Eng Technol; 1999; 23(4):144-51. PubMed ID: 10561825
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Laboratory testing of three intracranial pressure microtransducers: technical report.
    Czosnyka M; Czosnyka Z; Pickard JD
    Neurosurgery; 1996 Jan; 38(1):219-24. PubMed ID: 8747977
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The evaluation of the wave-form analysis capability of a new strain-gauge intracranial pressure MicroSensor.
    Piper IR; Miller JD
    Neurosurgery; 1995 Jun; 36(6):1142-4; discussion 1144-5. PubMed ID: 7643994
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases.
    Gelabert-González M; Ginesta-Galan V; Sernamito-García R; Allut AG; Bandin-Diéguez J; Rumbo RM
    Acta Neurochir (Wien); 2006 Apr; 148(4):435-41. PubMed ID: 16374566
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system.
    Koskinen LO; Olivecrona M
    Neurosurgery; 2005 Apr; 56(4):693-8; discussion 693-8. PubMed ID: 15792507
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Significance of intracranial pressure waveform analysis after head injury.
    Czosnyka M; Guazzo E; Whitehouse M; Smielewski P; Czosnyka Z; Kirkpatrick P; Piechnik S; Pickard JD
    Acta Neurochir (Wien); 1996; 138(5):531-41; discussion 541-2. PubMed ID: 8800328
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An evaluation of the camino ventricular bolt system in clinical practice.
    Chambers KR; Kane PJ; Choksey MS; Mendelow AD
    Neurosurgery; 1993 Nov; 33(5):866-8. PubMed ID: 8264885
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical evaluation of a miniature strain-gauge transducer for monitoring intracranial pressure.
    Gopinath SP; Robertson CS; Contant CF; Narayan RK; Grossman RG
    Neurosurgery; 1995 Jun; 36(6):1137-40; discussion 1140-1. PubMed ID: 7643993
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.