BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 9784645)

  • 1. Does the hemoglobin concentration in fetal blood interfere with the accuracy of fetal reflection pulse oximetry?
    Arikan GM; Haeusler MC; Haas J; Scholz H
    Fetal Diagn Ther; 1998; 13(4):236-40. PubMed ID: 9784645
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The relationship between oxygen saturation and pH in umbilical blood: implications for intrapartum fetal oxygen saturation monitoring.
    Dildy GA; Thorp JA; Yeast JD; Clark SL
    Am J Obstet Gynecol; 1996 Sep; 175(3 Pt 1):682-7. PubMed ID: 8828434
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Outcome measures in perinatal medicine--pO2 and SO2. With remarks on pulse oximetry].
    Roemer VM
    Z Geburtshilfe Neonatol; 2005 Oct; 209(5):173-85. PubMed ID: 16317628
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fetal pulse oximetry and visual on-line signal identification in the second stage of labor.
    Haeusler MC; Arikan G; Haas J; Kainer F
    Am J Obstet Gynecol; 1996 Oct; 175(4 Pt 1):1071-4. PubMed ID: 8885778
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is the correlation between fetal oxygen saturation and blood pH sufficient for the use of fetal pulse oximetry?
    Rijnders RJ; Mol BW; Reuwer PJ; Drogtrop AP; Vernooij MM; Visser GH
    J Matern Fetal Neonatal Med; 2002 Feb; 11(2):80-3. PubMed ID: 12375547
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulse oximetry and factors associated with hemoglobin oxygen desaturation in children with sickle cell disease.
    Rackoff WR; Kunkel N; Silber JH; Asakura T; Ohene-Frempong K
    Blood; 1993 Jun; 81(12):3422-7. PubMed ID: 7685205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Do fetal pulse oximetry readings at delivery correlate with cord blood oxygenation and acidaemia?
    McNamara H; Chung DC; Lilford R; Johnson N
    Br J Obstet Gynaecol; 1992 Sep; 99(9):735-8. PubMed ID: 1420012
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Correlation between fetal blood oxygen saturation and umbilical blood pH values.
    Linhartova L; Kurtansky A; Suska P
    Bratisl Lek Listy; 2009; 110(11):684-7. PubMed ID: 20120434
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fetal cerebral oxygenation measured by near-infrared spectroscopy shortly before birth and acid-base status at birth.
    Aldrich CJ; D'Antona D; Wyatt JS; Spencer JA; Peebles DM; Reynolds EO
    Obstet Gynecol; 1994 Nov; 84(5):861-6. PubMed ID: 7936527
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prediction of umbilical artery base excess by intrapartum fetal oxygen saturation monitoring.
    Alshimmiri M; Bocking AD; Gagnon R; Natale R; Richardson BS
    Am J Obstet Gynecol; 1997 Oct; 177(4):775-9. PubMed ID: 9369818
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reusable sensors in intrapartum foetal reflection pulse oximetry.
    Arikan MG; Haas J; Giuliani A; Haeusler M
    Biosens Bioelectron; 2002 Jun; 17(6-7):457-62. PubMed ID: 11959465
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reflectance pulse oximetry in fetal lambs.
    Dassel AC; Graaff R; Aarnoudse JG; Elstrodt JM; Heida P; Koelink MH; de Mul FF; Greve J
    Pediatr Res; 1992 Mar; 31(3):266-9. PubMed ID: 1561013
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of fetal intrapartum hypoxia by middle cerebral and umbilical artery Doppler velocimetry with simultaneous cardiotocography and pulse oximetry.
    Siristatidis C; Salamalekis E; Kassanos D; Loghis C; Creatsas G
    Arch Gynecol Obstet; 2004 Dec; 270(4):265-70. PubMed ID: 14600768
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The clinical significance of base excess (BEB) and base excess in the extracellular fluid compartment (BEEcf) with and without correction to real oxygen saturation of haemoglobin.
    Roemer VM
    Z Geburtshilfe Neonatol; 2011 Jun; 215(3):115-24. PubMed ID: 21755484
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical usefulness of pulse oximetry in the fetus with non-reassuring heart rate pattern?
    Schmidt S; Koslowski S; Sierra F; Meyer-Wittkopf M; Heller G
    J Perinat Med; 2000; 28(4):298-305. PubMed ID: 11031700
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fetal pulse oximetry: influence of tissue blood content and hemoglobin concentration in a new in-vitro model.
    Edrich T; Rall G; Knitza R
    Eur J Obstet Gynecol Reprod Biol; 1997 Mar; 72 Suppl():S29-34. PubMed ID: 9134410
    [TBL] [Abstract][Full Text] [Related]  

  • 17. How well does reflectance pulse oximetry reflect intrapartum fetal acidosis?
    Stiller R; von Mering R; König V; Huch A; Huch R
    Am J Obstet Gynecol; 2002 Jun; 186(6):1351-7. PubMed ID: 12066121
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reflectance pulse oximetry in fetal lambs: subcutaneous vessels and vasoconstriction affect its reliability.
    Nijland R; Jongsma HW; Verbruggen IM; Nijhuis JG
    J Clin Monit; 1996 May; 12(3):225-30. PubMed ID: 8823646
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous monitoring of fetal oxygen saturation by pulse oximetry.
    Luttkus A; Fengler TW; Friedmann W; Dudenhausen JW
    Obstet Gynecol; 1995 Feb; 85(2):183-6. PubMed ID: 7529914
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation of a non-invasive pulse CO-oximetry based hemoglobin estimation in normal blood donors.
    Al-Khabori M; Al-Riyami AZ; Al-Farsi K; Al-Huneini M; Al-Hashim A; Al-Kemyani N; Daar S
    Transfus Apher Sci; 2014 Feb; 50(1):95-8. PubMed ID: 24268769
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.