These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [Intraoperative EEG monitoring using a neural network]. Eckert O; Werry C; Neulinger A; Pichlmayr I Biomed Tech (Berl); 1997 Apr; 42(4):78-84. PubMed ID: 9235113 [TBL] [Abstract][Full Text] [Related]
3. [Automatic EEG data processing in a multicenter study]. Nahm W; Stockmanns G; Daumer M; Abke J; Konecny E; Kochs E Biomed Tech (Berl); 1998; 43 Suppl():146-7. PubMed ID: 9859299 [No Abstract] [Full Text] [Related]
4. [The Narcotrend monitor. Development and interpretation algorithms]. Schultz B; Kreuer S; Wilhelm W; Grouven U; Schultz A Anaesthesist; 2003 Dec; 52(12):1143-8. PubMed ID: 14691627 [TBL] [Abstract][Full Text] [Related]
5. Identification of EEG patterns occurring in anesthesia by means of autoregressive parameters. Bender R; Schultz B; Schultz A; Pichlmayr I Biomed Tech (Berl); 1991 Oct; 36(10):236-40. PubMed ID: 1768768 [TBL] [Abstract][Full Text] [Related]
6. An Unsupervised Method for Artefact Removal in EEG Signals. Mur A; Dormido R; Duro N Sensors (Basel); 2019 May; 19(10):. PubMed ID: 31109062 [TBL] [Abstract][Full Text] [Related]
7. Reference layer artefact subtraction (RLAS): a novel method of minimizing EEG artefacts during simultaneous fMRI. Chowdhury ME; Mullinger KJ; Glover P; Bowtell R Neuroimage; 2014 Jan; 84():307-19. PubMed ID: 23994127 [TBL] [Abstract][Full Text] [Related]
8. Multimodal detection of head-movement artefacts in EEG. O'Regan S; Marnane W J Neurosci Methods; 2013 Aug; 218(1):110-20. PubMed ID: 23685269 [TBL] [Abstract][Full Text] [Related]
9. Auditory evoked potentials for the assessment of depth of anaesthesia: different configurations of artefact detection algorithms. Luecke D; Stockmanns G; Gallinat M; Kochs EF; Schneider G Biomed Tech (Berl); 2007 Feb; 52(1):90-5. PubMed ID: 17313341 [TBL] [Abstract][Full Text] [Related]
10. [Development and realization of an EEG simulator]. Nahm W; Gehring H; Abke J; Wunderlich M; Stockmanns G; Konecny E Biomed Tech (Berl); 1997; 42 Suppl():27-8. PubMed ID: 9517032 [No Abstract] [Full Text] [Related]
11. [Neurophysiologic monitoring in neurosurgical vascular operations: specific technical requirements and their conversion]. Hinrichs H; Heinze HJ; Gaab MR EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb; 1992 Dec; 23(4):195-202. PubMed ID: 1486824 [TBL] [Abstract][Full Text] [Related]
12. The deleterious effect of ocular artefacts on the quantitative EEG, and a remedy. Gasser T; Ziegler P; Gattaz WF Eur Arch Psychiatry Clin Neurosci; 1992; 241(6):352-6. PubMed ID: 1504112 [TBL] [Abstract][Full Text] [Related]
13. Automated detection of artefacts in neonatal EEG with residual neural networks. Webb L; Kauppila M; Roberts JA; Vanhatalo S; Stevenson NJ Comput Methods Programs Biomed; 2021 Sep; 208():106194. PubMed ID: 34118491 [TBL] [Abstract][Full Text] [Related]
14. A trend-detection algorithm for intraoperative EEG monitoring. Hinrichs H; Feistner H; Heinze HJ Med Eng Phys; 1996 Dec; 18(8):626-31. PubMed ID: 8953554 [TBL] [Abstract][Full Text] [Related]
15. [EEG monitoring for quantifying the "depth of anesthesia": possibilities and limits]. Schüttler J Klin Anasthesiol Intensivther; 1994; 46():306-18. PubMed ID: 8065106 [No Abstract] [Full Text] [Related]
19. Automatic detection of EEG artefacts arising from head movements. O' Regan S; Faul S; Marnane W Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():6353-6. PubMed ID: 21096691 [TBL] [Abstract][Full Text] [Related]
20. Automatic classification algorithms of the EEG monitor Narcotrend for routinely recorded EEG data from general anaesthesia: a validation study. Schultz B; Grouven U; Schultz A Biomed Tech (Berl); 2002; 47(1-2):9-13. PubMed ID: 11921636 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]