These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 9790092)

  • 1. Dialysate pressure isobars in a hollow-fiber dialyzer determined from magnetic resonance imaging and numerical simulation of dialysate flow.
    Osuga T; Obata T; Ikehira H; Tanada S; Sasaki Y; Naito H
    Artif Organs; 1998 Oct; 22(10):907-9. PubMed ID: 9790092
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique.
    Ronco C; Brendolan A; Crepaldi C; Rodighiero M; Scabardi M
    J Am Soc Nephrol; 2002 Jan; 13 Suppl 1():S53-61. PubMed ID: 11792763
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of dialyzer jacket structure and hollow-fiber dialysis membranes to achieve high dialysis performance.
    Hirano A; Yamamoto K; Matsuda M; Ogawa T; Yakushiji T; Miyasaka T; Sakai K
    Ther Apher Dial; 2011 Feb; 15(1):66-74. PubMed ID: 21272255
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detection of small degree of nonuniformity in dialysate flow in hollow-fiber dialyzer using proton magnetic resonance imaging.
    Osuga T; Obata T; Ikehira H
    Magn Reson Imaging; 2004 Apr; 22(3):417-20. PubMed ID: 15062938
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Proton magnetic resonance imaging of flow motion of heavy water injected into a hollow fiber dialyzer filled with saline.
    Osuga T; Obata T; Ikehira H
    Magn Reson Imaging; 2004 Apr; 22(3):413-6. PubMed ID: 15062937
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technical evaluation of dialysate flow in a newly designed dialyzer.
    Yamamoto K; Matsukawa H; Yakushiji T; Fukuda M; Hiyoshi T; Sakai K
    ASAIO J; 2007; 53(1):36-40. PubMed ID: 17237647
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fluid mechanics and crossfiltration in hollow-fiber hemodialyzers.
    Ronco C
    Contrib Nephrol; 2007; 158():34-49. PubMed ID: 17684341
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance.
    Ronco C; Scabardi M; Goldoni M; Brendolan A; Crepaldi C; La Greca G
    Int J Artif Organs; 1997 May; 20(5):261-6. PubMed ID: 9209926
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: a magnetic resonance imaging study.
    Poh CK; Hardy PA; Liao Z; Huang Z; Clark WR; Gao D
    ASAIO J; 2003; 49(4):440-8. PubMed ID: 12918588
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional dialysate flow analysis in a hollow-fiber dialyzer by perfusion computed tomography.
    Kim JC; Kim JH; Kim HC; Kim KG; Lee JC; Kang E; Kim HC; Min BG; Ronco C
    Int J Artif Organs; 2008 Jun; 31(6):553-60. PubMed ID: 18609508
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new method to evaluate the local clearance at different annular rings inside hemodialyzers.
    Huang Z; Klein E; Li B; Poh C; Liao Z; Clark WR; Gao D
    ASAIO J; 2003; 49(6):692-7. PubMed ID: 14655736
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mathematical model of calcium exchange during haemodialysis using a citrate containing dialysate.
    Aniort J; Chupin L; Cîndea N
    Math Med Biol; 2018 Mar; 35(suppl_1):87-120. PubMed ID: 29059342
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of fiber structure on dialysate flow profile and hollow-fiber hemodialyzer reliability: CT perfusion study.
    Kim JC; Kim JH; Kim HC; Kang E; Kim KG; Kim HC; Min BG; Ronco C
    Int J Artif Organs; 2008 Nov; 31(11):944-50. PubMed ID: 19089796
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated monitoring of hemodialysis adequacy by dialysis machines: potential benefits to patients and cost savings.
    Daugirdas JT; Tattersall JE
    Kidney Int; 2010 Nov; 78(9):833-5. PubMed ID: 20948540
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow distributions in hollow fiber hemodialyzers using magnetic resonance Fourier velocity imaging.
    Zhang J; Parker DL; Leypoldt JK
    ASAIO J; 1995; 41(3):M678-82. PubMed ID: 8573891
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow distribution analysis by helical scanning in polysulfone hemodialyzers: effects of fiber structure and design on flow patterns and solute clearances.
    Ronco C; Levin N; Brendolan A; Nalesso F; Cruz D; Ocampo C; Kuang D; Bonello M; De Cal M; Corradi V; Ricci Z
    Hemodial Int; 2006 Oct; 10(4):380-8. PubMed ID: 17014516
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and assessment of the new APS dialyzer (APS-SA series).
    Fukuda M; Miyazaki M; Uezumi S; Yoshida M
    J Artif Organs; 2006; 9(3):192-8. PubMed ID: 16998705
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodialysis blood access flow rates can be estimated accurately from on-line dialysate urea measurements and the knowledge of effective dialyzer urea clearance.
    Lindsay RM; Sternby J; Olde B; Persson R; Thatcher ME; Sargent K
    Clin J Am Soc Nephrol; 2006 Sep; 1(5):960-4. PubMed ID: 17699313
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving hollow fiber dialyzer efficiency with a recirculating dialysate system. I: Theory and applicability.
    Prado M; Roa LM; Palma A; Milán JA
    Ann Biomed Eng; 2005 May; 33(5):642-55. PubMed ID: 15981864
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An in vivo analysis of reverse ultrafiltration during high-flux and high-efficiency dialysis.
    Hyver SW; Petersen J; Cajias J
    Am J Kidney Dis; 1992 May; 19(5):439-43. PubMed ID: 1585931
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.