These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 9793083)
1. Reliability of an automatic sensing test with beat-to-beat display of the signal amplitude. Lazarus A; Cazeau S; Ritter P; Gras D; Mugica J Pacing Clin Electrophysiol; 1998 Oct; 21(10):1881-4. PubMed ID: 9793083 [TBL] [Abstract][Full Text] [Related]
2. Uni- and bipolar pacing threshold measurements with capturecontrol, a new automatic pacemaker function for capture verification. Comparison of the automatic and the manual pacing threshold measurement. Schuchert A; Meinertz T Cardiology; 1999; 92(3):210-3. PubMed ID: 10754353 [TBL] [Abstract][Full Text] [Related]
3. Automatic management of atrial and ventricular stimulation in a contemporary unselected population of pacemaker recipients: the ESSENTIAL Registry. Biffi M; Bertini M; Saporito D; Belotti G; Quartieri F; Piancastelli M; Pucci A; Boggian G; Mazzocca GF; Giorgi D; Diotallevi P; Diemberger I; Martignani C; Pancaldi S; Ziacchi M; Marcantoni L; Toselli T; Attala S; Iori M; Bottoni N; Argnani S; Tomasi C; Sassone B; Boriani G Europace; 2016 Oct; 18(10):1551-1560. PubMed ID: 27305923 [TBL] [Abstract][Full Text] [Related]
4. Performance evaluation of a right atrial automatic capture verification algorithm using two different sensing configurations. Sperzel J; Goetze S; Kennergren C; Biffi M; Brooke MJ; Vireca E; Saha S; Schubert B; Butter C Pacing Clin Electrophysiol; 2009 May; 32(5):579-87. PubMed ID: 19422578 [TBL] [Abstract][Full Text] [Related]
5. Reduction of pacing output coupling capacitance for sensing the evoked response. Sperzel J; Neuzner J; Schwarz T; Zhu Q; König A; Kay GN Pacing Clin Electrophysiol; 2001 Sep; 24(9 Pt 1):1377-82. PubMed ID: 11584460 [TBL] [Abstract][Full Text] [Related]
6. Reliability of single-lead VDD atrial sensing and pacing during exercise. Guyomar Y; Graux P; Carlioz R; Moulin C; Dutoit A Pacing Clin Electrophysiol; 1999 Dec; 22(12):1747-52. PubMed ID: 10642127 [TBL] [Abstract][Full Text] [Related]
7. [Analysis of intracardial electrograms in pacemakers and ICD systems by Biotronik]. Wetzel U; Piorkowski C; Richter S; Müssigbrodt A; Kucher A; Hindricks G Herzschrittmacherther Elektrophysiol; 2010 Mar; 21(1):6-17. PubMed ID: 20309671 [TBL] [Abstract][Full Text] [Related]
9. VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system. Naegeli B; Osswald S; Pfisterer M; Burkart F Pacing Clin Electrophysiol; 1996 Apr; 19(4 Pt 1):455-64. PubMed ID: 8848393 [TBL] [Abstract][Full Text] [Related]
18. Underestimation of pacing threshold as determined by an automatic ventricular threshold testing algorithm. Sauer WH; Cooper JM; Lai RW; Verdino RJ Pacing Clin Electrophysiol; 2006 Sep; 29(9):1028-30. PubMed ID: 16981932 [TBL] [Abstract][Full Text] [Related]
19. Benefits of intracardiac electrograms and programmable sensing polarity in preventing pacemaker inhibition due to spurious screw-in lead signals. Nalos PC; Nyitray W Pacing Clin Electrophysiol; 1990 Sep; 13(9):1101-4. PubMed ID: 1700383 [TBL] [Abstract][Full Text] [Related]
20. Left ventricular pacing by automatic capture verification. Biffi M; Bertini M; Ziacchi M; Boriani G Europace; 2007 Dec; 9(12):1177-81. PubMed ID: 17932022 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]