4. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves. Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181 [TBL] [Abstract][Full Text] [Related]
5. Doppler assessment of mechanical aortic valve prostheses: effect of valve design and size of the aorta. Mascherbauer J; Schima H; Maurer G; Baumgartner H J Heart Valve Dis; 2004 Sep; 13(5):823-30. PubMed ID: 15473486 [TBL] [Abstract][Full Text] [Related]
6. Comparative study of the hydrodynamic function of the size 19mm and 21mm St. Jude Medical Hemodynamic Plus Bileaflet Heart valves. Fisher J J Heart Valve Dis; 1994 Jan; 3(1):75-80. PubMed ID: 8162222 [TBL] [Abstract][Full Text] [Related]
7. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve. Shu MC; Gross JM; O'Rourke KK; Yoganathan AP J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854 [TBL] [Abstract][Full Text] [Related]
8. Pressure and flow fields in the hinge region of bileaflet mechanical heart valves. Gao ZB; Hosein N; Dai FF; Hwang NH J Heart Valve Dis; 1999 Mar; 8(2):197-205. PubMed ID: 10224581 [TBL] [Abstract][Full Text] [Related]
9. Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves. Gerosa G; Tarzia V; Rizzoli G; Bottio T J Thorac Cardiovasc Surg; 2006 May; 131(5):1058-64. PubMed ID: 16678590 [TBL] [Abstract][Full Text] [Related]
10. Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: implications for in vivo assessment of prosthetic valve function. Fontaine AA; Heinrich RS; Walker PG; Pedersen EM; Scheidegger MB; Boesiger P; Walton SP; Yoganathan AP J Heart Valve Dis; 1996 Jan; 5(1):66-73. PubMed ID: 8834728 [TBL] [Abstract][Full Text] [Related]
11. The new St. Jude Medical regent mechanical heart valve: laboratory measurements of hydrodynamic performance. Walker DK; Brendzel AM; Scotten LN J Heart Valve Dis; 1999 Nov; 8(6):687-96. PubMed ID: 10616249 [TBL] [Abstract][Full Text] [Related]
12. In-vitro testing of three totally supra-annular bileaflet mechanical valves: hydrodynamics in the Sheffield pulse duplicator. Bottio T; Tarzia V; Rizzoli G; Gerosa G J Heart Valve Dis; 2008 Mar; 17(2):222-6. PubMed ID: 18512495 [TBL] [Abstract][Full Text] [Related]
13. The hemodynamic effects of mechanical prosthetic valve type and orientation on fluid mechanical energy loss and pressure drop in in vitro models of ventricular hypertrophy. Travis BR; Heinrich RS; Ensley AE; Gibson DE; Hashim S; Yoganathan AP J Heart Valve Dis; 1998 May; 7(3):345-54. PubMed ID: 9651851 [TBL] [Abstract][Full Text] [Related]
14. Bubble formation on St. Jude Medical mechanical heart valves: an in-vitro study. Milo S; Gutfinger C; Chu GY; Gharib M J Heart Valve Dis; 2003 May; 12(3):406-10. PubMed ID: 12803343 [TBL] [Abstract][Full Text] [Related]
17. Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve. Barbaro V; Grigioni M; Daniele C; D'Avenio G Technol Health Care; 1998 Nov; 6(4):259-70. PubMed ID: 9924953 [TBL] [Abstract][Full Text] [Related]
18. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves. Bottio T; Caprili L; Casarotto D; Gerosa G J Thorac Cardiovasc Surg; 2004 Sep; 128(3):457-62. PubMed ID: 15354108 [TBL] [Abstract][Full Text] [Related]
20. Experimental study on the Reynolds and viscous shear stress of bileaflet mechanical heart valves in a pneumatic ventricular assist device. Lee H; Tatsumi E; Taenaka Y ASAIO J; 2009; 55(4):348-54. PubMed ID: 19521236 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]