These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 9802668)

  • 1. Effect of modular head seating on the cement-stem interface strength of femoral prostheses.
    Weiss JM; Novak VP; Belkoff SM
    J Arthroplasty; 1998 Oct; 13(7):799-803. PubMed ID: 9802668
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Factors affecting cement strains near the tip of a cemented femoral component.
    Estok DM; Orr TE; Harris WH
    J Arthroplasty; 1997 Jan; 12(1):40-8. PubMed ID: 9021500
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
    Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
    J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Uncemented femoral revision arthroplasty using the modular revision prosthesis MRP-TITAN revision stem.
    Mumme T; Müller-Rath R; Andereya S; Wirtz DC
    Oper Orthop Traumatol; 2007 Mar; 19(1):56-77. PubMed ID: 17345027
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reinforcement of bone cement around the femoral prosthesis tip by pre-coated wire coil: a human cadaver bone study.
    Kim JK; Park JB
    Biomed Mater Eng; 1996; 6(3):159-64. PubMed ID: 8922261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Deformation pattern and load transfer of an uncemented femoral stem with modular necks. An experimental study in human cadaver femurs.
    Enoksen CH; Gjerdet NR; Klaksvik J; Arthursson AJ; Schnell-Husby O; Wik TS
    Clin Biomech (Bristol, Avon); 2016 Feb; 32():28-33. PubMed ID: 26785385
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel methods to study functional loading micromechanics at the stem-cement and cement-bone interface in cemented femoral hip replacements.
    Race A; Miller MA; Mann KA
    J Biomech; 2010 Mar; 43(4):788-91. PubMed ID: 19906377
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bond strength analysis of the bone cement- stem interface of hip arthroplasties.
    Zhang LF; Ge SR; Liu HT; Guo KJ; Han SY; Qi JY
    Asian Pac J Trop Med; 2014 Feb; 7(2):153-9. PubMed ID: 24461531
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Integrity of the stem-cement interface in THA: effects of stem surface finish and cement porosity.
    Iesaka K; Jaffe WL; Kummer FJ
    J Biomed Mater Res B Appl Biomater; 2008 Oct; 87(1):77-82. PubMed ID: 18386841
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of stem length on mechanics of the femoral hip component after cemented revision.
    Mann KA; Ayers DC; Damron TA
    J Orthop Res; 1997 Jan; 15(1):62-8. PubMed ID: 9066528
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant.
    Lee IY; Skinner HB; Keyak JH
    Iowa Orthop J; 1993; 13():155-9. PubMed ID: 7820736
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Femoral component loosening in hip arthroplasty. Cadaver study of subsidence and hoop strain.
    Manley MT; Stern LS; Kotzar G; Stulberg BN
    Acta Orthop Scand; 1987 Oct; 58(5):485-90. PubMed ID: 3425274
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanics of the femoral component of total hip prostheses with particular reference to the stress in the bone-cement.
    Yettram AL; Wright KW
    J Biomed Eng; 1979 Oct; 1(4):281-5. PubMed ID: 537354
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intramedullary fixation of implants pre-coated with bone cement: a preliminary study.
    Park JB; Malstrom CS; von Recum AF
    Biomater Med Devices Artif Organs; 1978; 6(4):361-73. PubMed ID: 749943
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vital staining of bone in stable, retrieved femoral surface replacement prostheses: a microscopic study of undecalcified ground sections.
    Morberg PH; Johansson CB; Reigstad A; Røkkum M
    J Arthroplasty; 2001 Dec; 16(8):1004-9. PubMed ID: 11740755
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intramedullary fixation of artificial hip joints with bone cement-precoated implants. I. Interfacial strengths.
    Barb W; Park JB; Kenner GH; von Recum AF
    J Biomed Mater Res; 1982 Jul; 16(4):447-58. PubMed ID: 7107660
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prediction of micromotion initiation of an implanted femur under physiological loads and constraints using the finite element method.
    Andreaus U; Colloca M
    Proc Inst Mech Eng H; 2009 Jul; 223(5):589-605. PubMed ID: 19623912
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical aspects of degree of cement bonding and implant wedge effect.
    Yoon YS; Oxland TR; Hodgson AJ; Duncan CP; Masri BA; Choi D
    Clin Biomech (Bristol, Avon); 2008 Nov; 23(9):1141-7. PubMed ID: 18584929
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Early cement damage around a femoral stem is concentrated at the cement/bone interface.
    Race A; Miller MA; Ayers DC; Mann KA
    J Biomech; 2003 Apr; 36(4):489-96. PubMed ID: 12600339
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.