These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 9803449)

  • 61. Computerised audiovisual event recording for infant apnoea and bradycardia.
    Brouillette RT; Tsirigotis D; Leimanis A; Côté A; Morielli A
    Med Biol Eng Comput; 2000 Sep; 38(5):477-82. PubMed ID: 11094801
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Infant respiration monitoring--evaluation of a simple home monitor.
    Munley AJ; Railton R; Fisher J; Barclay RP
    J Med Eng Technol; 1985; 9(6):261-5. PubMed ID: 3910837
    [TBL] [Abstract][Full Text] [Related]  

  • 63. [The role of complementary examinations and home monitoring in patient at risk from apparent life threatening event, apneas and sudden infant death syndrome].
    Martínez Monseny A; Bobillo Pérez S; Martínez Planas A; García García JJ
    An Pediatr (Barc); 2015 Aug; 83(2):104-8. PubMed ID: 25801068
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Cardiorespiratory events recorded on home monitors: the effect of prematurity on later serious events.
    Naulaers G; Daniels H; Allegaert K; Rayyan M; Debeer A; Devlieger H
    Acta Paediatr; 2007 Feb; 96(2):195-8. PubMed ID: 17429904
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Home event recordings of oxygenation, breathing movements, and heart rate and rhythm in infants with recurrent life-threatening events.
    Poets CF; Samuels MP; Noyes JP; Hewertson J; Hartmann H; Holder A; Southall DP
    J Pediatr; 1993 Nov; 123(5):693-701. PubMed ID: 8229476
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Accuracy of acoustic respiration rate monitoring in pediatric patients.
    Patino M; Redford DT; Quigley TW; Mahmoud M; Kurth CD; Szmuk P
    Paediatr Anaesth; 2013 Dec; 23(12):1166-73. PubMed ID: 24033591
    [TBL] [Abstract][Full Text] [Related]  

  • 67. [Reliability of home monitoring with event-recording compared with polysomnography in infants].
    de Nardi S; Paditz E; Erler T; Gruntzke A
    Wien Klin Wochenschr; 2003 Jul; 115(12):421-8. PubMed ID: 12918186
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Can home monitoring reduce mortality in infants at increased risk of sudden infant death syndrome? A systematic review.
    Strehle EM; Gray WK; Gopisetti S; Richardson J; McGuire J; Malone S
    Acta Paediatr; 2012 Jan; 101(1):8-13. PubMed ID: 21910748
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Monitoring apnea of prematurity: validity of nursing documentation and bedside cardiorespiratory monitor.
    Amin SB; Burnell E
    Am J Perinatol; 2013 Sep; 30(8):643-8. PubMed ID: 23254381
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Observations on the limitations of two apnea/respiration monitors commonly used in the home.
    MacFadyen UM; Simpson H
    Pediatr Pulmonol; 1985; 1(6):319-24. PubMed ID: 4094823
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Home monitors for infants: use, misuse, and "over-the-counter" use.
    Kahn A; Blum D; Rebuffat E; Sottiaux M; Levitt J; Bochner A; Alexander M; Grosswasser J; Muller MF
    Eur J Pediatr; 1990 Feb; 149(5):356-8. PubMed ID: 2311633
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Home documented monitoring of cardiorespiratory pattern and oxygen saturation in healthy infants.
    Hunt CE; Hufford DR; Bourguignon C; Oess MA
    Pediatr Res; 1996 Feb; 39(2):216-22. PubMed ID: 8825790
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Toward better home respiratory monitoring: a comparison of impedance and inductance pneumography.
    Miyasaka K; Kondo Y; Suzuki T; Sakai H; Takata M
    Acta Paediatr Jpn; 1994 Jun; 36(3):307-10. PubMed ID: 8091986
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Apnea in newborn infants: approach to management.
    Banagale RC; Roloff DW; Howatt WF
    Resuscitation; 1984 Feb; 11(1-2):9-20. PubMed ID: 6322269
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Short-term event recording as a measure to rule out false alarms and to shorten the duration of home monitoring in infants.
    Zotter H; Schenkeli R; Kurz R; Kerbl R
    Wien Klin Wochenschr; 2003 Jan; 115(1-2):53-7. PubMed ID: 12658912
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Home monitoring in children at risk of sudden infant death.
    Josten KU
    Int J Clin Monit Comput; 1988; 5(2):119-23. PubMed ID: 3397613
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Infant home respiratory monitoring using pulse oximetry.
    Seddon P; Sobowiec-Kouman S; Wertheim D
    Arch Dis Child; 2018 Jun; 103(6):603-605. PubMed ID: 27390365
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Accurate segmentation of respiration waveforms from infants enabling identification and classification of irregular breathing patterns.
    Wilks PA; English MJ
    Med Eng Phys; 1994 Jan; 16(1):19-23. PubMed ID: 8162260
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Access to home apnea monitoring and its impact on rehospitalization among very-low-birth-weight infants.
    Malloy MH; Graubard B
    Arch Pediatr Adolesc Med; 1995 Mar; 149(3):326-32. PubMed ID: 7858696
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Pneumogram recordings and cerebral computed tomography as predictors of the severity of infant apnea.
    Deacon JS; Hynan MT; Blaser C
    J Perinatol; 1993; 13(6):442-7. PubMed ID: 8308586
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.