These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 9804492)

  • 1. New needle for two needle hemodialysis.
    Zarate AR
    ASAIO J; 1998; 44(5):M549-54. PubMed ID: 9804492
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variation of flow rate and angle of injected venous needle on influencing intimal hyperplasia at the venous anastomosis of the hemodialysis graft.
    Yang L; Yin A; Liu W
    Australas Phys Eng Sci Med; 2017 Mar; 40(1):239-248. PubMed ID: 28168585
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computational Model of the Arterial and Venous Needle During Hemodialysis.
    Fulker D; Simmons A; Barber T
    J Biomech Eng; 2017 Jan; 139(1):. PubMed ID: 27537240
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Turbulent flow evaluation of the venous needle during hemodialysis.
    Unnikrishnan S; Huynh TN; Brott BC; Ito Y; Cheng CH; Shih AM; Allon M; Anayiotos AS
    J Biomech Eng; 2005 Dec; 127(7):1141-6. PubMed ID: 16502656
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of venous needle turbulence during ex vivo hemodialysis on endothelial morphology and nitric oxide formation.
    Huynh TN; Chacko BK; Teng X; Brott BC; Allon M; Kelpke SS; Thompson JA; Patel RP; Anayiotos AS
    J Biomech; 2007; 40(10):2158-66. PubMed ID: 17161843
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemodynamic effects of spiral ePTFE prosthesis compared with standard arteriovenous graft in a carotid to jugular vein porcine model.
    Jahrome OK; Hoefer I; Houston GJ; Stonebridge PA; Blankestijn PJ; Moll FL; de Borst GJ
    J Vasc Access; 2011; 12(3):224-30. PubMed ID: 21140362
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The flow field near a venous needle in hemodialysis: a computational study.
    Fulker D; Kang M; Simmons A; Barber T
    Hemodial Int; 2013 Oct; 17(4):602-11. PubMed ID: 23448433
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of arteriovenous graft flow rate on vascular access hemodynamics in a novel modular anastomotic valve device.
    McNally A; Akingba AG; Sucosky P
    J Vasc Access; 2018 Sep; 19(5):446-454. PubMed ID: 30192183
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review.
    Haruguchi H; Teraoka S
    J Artif Organs; 2003; 6(4):227-35. PubMed ID: 14691664
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sirolimus-eluting stents to abolish intimal hyperplasia and improve flow in porcine arteriovenous grafts: a 4-week follow-up study.
    Rotmans JI; Pattynama PM; Verhagen HJ; Hino I; Velema E; Pasterkamp G; Stroes ES
    Circulation; 2005 Mar; 111(12):1537-42. PubMed ID: 15781738
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prosthetic arteriovenous fistulas and venous anastomotic stenosis: influence of a high flow velocity on the development of intimal hyperplasia.
    Hofstra L; Bergmans DC; Leunissen KM; Hoeks AP; Kitslaar PJ; Tordoir JH
    Blood Purif; 1996; 14(5):345-9. PubMed ID: 8894129
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anastomotic intimal hyperplasia in prosthetic arteriovenous fistulas for hemodialysis is associated with initial high flow velocity and not with mismatch in elastic properties.
    Hofstra L; Bergmans DC; Leunissen KM; Hoeks AP; Kitslaar PJ; Daemen MJ; Tordoir JH
    J Am Soc Nephrol; 1995 Dec; 6(6):1625-33. PubMed ID: 8749690
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computational Fluid Dynamic Analysis of the Hemodialysis Plastic Cannula.
    Fulker D; Sayed Z; Simmons A; Barber T
    Artif Organs; 2017 Nov; 41(11):1035-1042. PubMed ID: 28591486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemodynamics in a compliant hydraulic in vitro model of straight versus tapered PTFE arteriovenous graft.
    Van Tricht I; De Wachter D; Tordoir J; Verdonck P
    J Surg Res; 2004 Feb; 116(2):297-304. PubMed ID: 15013369
    [TBL] [Abstract][Full Text] [Related]  

  • 15. External beam radiation therapy to prevent anastomotic intimal hyperplasia in prosthetic arteriovenous fistulas: results of a randomized trial.
    van Tongeren RB; Levendag PC; Coen VL; Schmitz PI; Gescher FM; Vernhout RM; Wittens CH; Bruijninckx CM
    Radiother Oncol; 2003 Oct; 69(1):73-7. PubMed ID: 14597359
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro testing of a newly developed arteriovenous double-outflow graft.
    Heise M; Kirschner P; Rabsch A; Zanow J; Settmacher U; Heidenhain C
    J Vasc Surg; 2010 Aug; 52(2):421-8. PubMed ID: 20591600
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bioengineered vascular access maintains structural integrity in response to arteriovenous flow and repeated needle puncture.
    Tillman BW; Yazdani SK; Neff LP; Corriere MA; Christ GJ; Soker S; Atala A; Geary RL; Yoo JJ
    J Vasc Surg; 2012 Sep; 56(3):783-93. PubMed ID: 22917043
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Predictive measures of vascular access thrombosis: a prospective study.
    May RE; Himmelfarb J; Yenicesu M; Knights S; Ikizler TA; Schulman G; Hernanz-Schulman M; Shyr Y; Hakim RM
    Kidney Int; 1997 Dec; 52(6):1656-62. PubMed ID: 9407514
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Beneficial effects of banding on venous intimal-medial hyperplasia in arteriovenous loop grafts.
    Fillinger MF; Reinitz ER; Schwartz RA; Resetarits DE; Paskanik AM; Bredenberg CE
    Am J Surg; 1989 Aug; 158(2):87-94. PubMed ID: 2757149
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of needles in vascular access for hemodialysis.
    Marticorena RM; Donnelly SM
    J Vasc Access; 2016 Mar; 17 Suppl 1():S32-7. PubMed ID: 26951901
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.