These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 9804529)

  • 1. Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques.
    Nakata M; Masuzawa T; Tatsumi E; Taenaka Y; Nishimura T; Tsukiya T; Takano H; Tsuchimoto K; Ohba K
    ASAIO J; 1998; 44(5):M714-8. PubMed ID: 9804529
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Flow pattern analysis of the Baylor total artificial heart.
    Meier D; Wernicke JT; Orime Y; Takatani S; Tasai K; Damm G; Naito K; Mizuguchi K; Makinouchi K; Glueck J
    Artif Organs; 1994 Dec; 18(12):923-32. PubMed ID: 7887830
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow visualization in the Baylor total artificial heart.
    Orime Y; Takatani S; Tasai K; Ohara Y; Naito K; Mizuguchi K; Makinouchi K; Rosenow SE; Glueck J; Noon GP
    Artif Organs; 1994 Jan; 18(1):73-9. PubMed ID: 8141661
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Baylor total artificial heart. Flow visualization studies.
    Orime Y; Takatani S; Tasai K; Ohara Y; Naito K; Mizuguchi K; Meier D; Wernicke JT; Damm G; Glueck J
    ASAIO J; 1994; 40(3):M499-505. PubMed ID: 8555566
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flow visualization in an artificial heart using diffuse and planar laser lighting.
    Mussivand T; Navarro R; Chen JF; Braun J; Harasaki H; Kiraly R; Batur C; McMillin C; Nosé Y
    ASAIO Trans; 1988; 34(3):317-21. PubMed ID: 3196528
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flow visualization for different port angles of a pulsatile ventricular assist device.
    Akagawa E; Lee H; Tatsumi E; Homma A; Tsukiya T; Taenaka Y
    J Artif Organs; 2012 Jun; 15(2):119-27. PubMed ID: 22038496
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diaphragm motion affects flow patterns in an artificial heart.
    Hochareon P; Manning KB; Fontaine AA; Deutsch S; Tarbell JM
    Artif Organs; 2003 Dec; 27(12):1102-9. PubMed ID: 14678424
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Basic study to develop the undulation pump for practical use: antithrombogenicity, hemolysis, and flow patterns inside the pump.
    Abe Y; Chinzei T; Isoyama T; Ono T; Mabuchi K; Imanishi K; Kouno A; Atsumi K; Fujimasa I; Imachi K
    Artif Organs; 1995 Jul; 19(7):691-3. PubMed ID: 8572975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flow visualization analysis for evaluation of shear and recirculation in a new closed-type, monopivot centrifugal blood pump.
    Asztalos B; Yamane T; Nishida M
    Artif Organs; 1999 Oct; 23(10):939-46. PubMed ID: 10564293
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental and Numerical Investigation of an Axial Rotary Blood Pump.
    Schüle CY; Thamsen B; Blümel B; Lommel M; Karakaya T; Paschereit CO; Affeld K; Kertzscher U
    Artif Organs; 2016 Nov; 40(11):E192-E202. PubMed ID: 27087467
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a miniature implantable left ventricular assist device using CAD/CAM technology.
    Okamoto E; Hashimoto T; Mitamura Y
    J Artif Organs; 2003; 6(3):162-7. PubMed ID: 14598098
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A newly designed jellyfish valve for an artificial heart blood pump.
    Imachi K; Fujimasa I; Mabuchi K; Chinzei T; Abe Y; Maeda K; Imanishi K; Kouno A; Ono T; Atsumi K
    ASAIO Trans; 1988; 34(3):726-8. PubMed ID: 3196591
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computational fluid dynamics of gap flow in a biocentrifugal blood pump.
    Chua LP; Song G; Yu SC; Lim TM
    Artif Organs; 2005 Aug; 29(8):620-8. PubMed ID: 16048478
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device.
    Akagawa E; Lee H; Tatsumi E; Homma A; Tsukiya T; Katagiri N; Kakuta Y; Nishinaka T; Mizuno T; Ota K; Kansaku R; Taenaka Y
    J Artif Organs; 2007; 10(2):85-91. PubMed ID: 17574510
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A numerical investigation to evaluate the washout of blood compartments in a total artificial heart.
    Luraghi G; De Gaetano F; Rodriguez Matas JF; Dubini G; Costantino ML; De Castilla H; Griffaton N; Vignale D; Palmisano A; Gentile G; Esposito A; Migliavacca F
    Artif Organs; 2020 Sep; 44(9):976-986. PubMed ID: 32348583
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Two-dimensional color-mapping of turbulent shear stress distribution downstream of two aortic bioprosthetic valves in vitro.
    Nygaard H; Giersiepen M; Hasenkam JM; Reul H; Paulsen PK; Rovsing PE; Westphal D
    J Biomech; 1992 Apr; 25(4):429-40. PubMed ID: 1583021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Numerical washout study of a pulsatile total artificial heart.
    Sonntag SJ; Kaufmann TA; Büsen MR; Laumen M; Gräf F; Linde T; Steinseifer U
    Int J Artif Organs; 2014 Mar; 37(3):241-52. PubMed ID: 24744169
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Numerical dye washout method as a tool for characterizing the heart valve flow: study of three standard mechanical heart valves.
    Goubergrits L; Kertzscher U; Affeld K; Petz C; Stalling D; Hege HC
    ASAIO J; 2008; 54(1):50-7. PubMed ID: 18204316
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of totally implantable electromechanical artificial heart systems: Baylor ventricular assist system.
    Sasaki T; Takatani S; Shiono M; Sakuma I; Glueck J; Noon GP; Nosé Y; DeBakey ME
    Artif Organs; 1992 Aug; 16(4):407-13. PubMed ID: 10078283
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics.
    Yoganathan AP; Sung HW; Woo YR; Jones M
    J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.