BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

344 related articles for article (PubMed ID: 9807561)

  • 41. Ex vivo experiment of saline-enhanced hepatic bipolar radiofrequency ablation with a perfused needle electrode: comparison with conventional monopolar and simultaneous monopolar modes.
    Lee JM; Kim SH; Han JK; Sohn KL; Choi BI
    Cardiovasc Intervent Radiol; 2005; 28(3):338-45. PubMed ID: 15789259
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Radiofrequency renal ablation: in vivo comparison of internally cooled, multitined expandable and internally cooled perfusion electrodes.
    Lee JM; Han JK; Chang JM; Chung SY; Son KR; Kim SH; Lee JY; Choi BI
    J Vasc Interv Radiol; 2006 Mar; 17(3):549-56. PubMed ID: 16567680
    [TBL] [Abstract][Full Text] [Related]  

  • 43. FEM analysis of RF breast ablation: multiprobe versus cool-tip electrode.
    Quaranta V; Manenti G; Bolacchi F; Cossu E; Pistolese CA; Buonomo OC; Carotenuto L; Piconi C; Simonetti G
    Anticancer Res; 2007; 27(2):775-84. PubMed ID: 17465202
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.
    Rempp H; Voigtländer M; Clasen S; Kempf S; Neugebauer A; Schraml C; Schmidt D; Claussen CD; Enderle MD; Goldberg SN; Pereira PL
    Invest Radiol; 2009 Dec; 44(12):763-8. PubMed ID: 19838120
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Radiofrequency ablation using a new type of internally cooled electrode with an adjustable active tip: an experimental study in ex vivo bovine and in vivo porcine livers.
    Cha J; Kim YS; Rhim H; Lim HK; Choi D; Lee MW
    Eur J Radiol; 2011 Mar; 77(3):516-21. PubMed ID: 19800188
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Large (>or=5.0-cm) HCCs: multipolar RF ablation with three internally cooled bipolar electrodes--initial experience in 26 patients.
    Seror O; N'Kontchou G; Ibraheem M; Ajavon Y; Barrucand C; Ganne N; Coderc E; Trinchet JC; Beaugrand M; Sellier N
    Radiology; 2008 Jul; 248(1):288-96. PubMed ID: 18483229
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Radiofrequency tissue ablation: increased lesion diameter with a perfusion electrode.
    Goldberg SN; Gazelle GS; Solbiati L; Rittman WJ; Mueller PR
    Acad Radiol; 1996 Aug; 3(8):636-44. PubMed ID: 8796727
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection: ex vivo bovine liver.
    Lee JM; Han JK; Kim SH; Shin KS; Lee JY; Park HS; Hur H; Choi BI
    Korean J Radiol; 2004; 5(4):258-65. PubMed ID: 15637476
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Hepatic radiofrequency ablation using multiple probes: ex vivo and in vivo comparative studies of monopolar versus multipolar modes.
    Lee JM; Han JK; Lee JY; Kim SH; Choi JY; Lee MW; Choi SH; Eo H; Choi BI
    Korean J Radiol; 2006; 7(2):106-17. PubMed ID: 16799271
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Multiple-electrode radiofrequency ablation of in vivo porcine liver: comparative studies of consecutive monopolar, switching monopolar versus multipolar modes.
    Lee JM; Han JK; Kim HC; Kim SH; Kim KW; Joo SM; Choi BI
    Invest Radiol; 2007 Oct; 42(10):676-83. PubMed ID: 17984764
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Multiple-electrode radiofrequency ablation: simultaneous production of separate zones of coagulation in an in vivo porcine liver model.
    Laeseke PF; Sampson LA; Haemmerich D; Brace CL; Fine JP; Frey TM; Winter TC; Lee FT
    J Vasc Interv Radiol; 2005 Dec; 16(12):1727-35. PubMed ID: 16371542
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Large-volume radiofrequency ablation of ex vivo bovine liver with multiple cooled cluster electrodes.
    Haemmerich D; Lee FT; Schutt DJ; Sampson LA; Webster JG; Fine JP; Mahvi DM
    Radiology; 2005 Feb; 234(2):563-8. PubMed ID: 15601891
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Small liver colorectal metastases treated with percutaneous radiofrequency ablation: local response rate and long-term survival with up to 10-year follow-up.
    Solbiati L; Ahmed M; Cova L; Ierace T; Brioschi M; Goldberg SN
    Radiology; 2012 Dec; 265(3):958-68. PubMed ID: 23091175
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Optimization of wet radiofrequency ablation using a perfused-cooled electrode: a comparative study in ex vivo bovine livers.
    Lee JM; Han JK; Kim SH; Lee JY; Shin KS; Han CJ; Lee MW; Choi JI; Choi BI
    Korean J Radiol; 2004; 5(4):250-7. PubMed ID: 15637475
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Radiofrequency ablation: basic principles, techniques and challenges].
    Pereira PL; Trübenbach J; Schmidt D
    Rofo; 2003 Jan; 175(1):20-7. PubMed ID: 12525976
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Radiofrequency Ablation by a 21-Gauge Internally Cooled Electrode: Ex Vivo and In Vivo Evaluation by Rat Liver.
    Takaki H; Kodama Y; Miyamoto H; Iijima Y; Kikuchi Y; Kodama H; Ueshima E; Nakasho K; Wada R; Yamakado K
    Cardiovasc Intervent Radiol; 2021 Jan; 44(1):150-155. PubMed ID: 33078230
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparison of renal ablation with monopolar radiofrequency and hypertonic-saline-augmented bipolar radiofrequency: in vitro and in vivo experimental studies.
    Lee JM; Han JK; Choi SH; Kim SH; Lee JY; Shin KS; Han CJ; Choi BI
    AJR Am J Roentgenol; 2005 Mar; 184(3):897-905. PubMed ID: 15728615
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A comparison of internally water-perfused and cryogenically cooled monopolar and bipolar radiofrequency applicators in ex vivo liver samples.
    Rempp H; Mezger D; Voigtlaender M; Scharpf M; Hoffmann R; Pereira PL; Enderle MD; Claussen CD; Clasen S
    Acad Radiol; 2014 May; 21(5):661-6. PubMed ID: 24703480
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Radiofrequency liver ablation: experimental comparative study of water-cooled versus expandable systems.
    de Baere T; Denys A; Wood BJ; Lassau N; Kardache M; Vilgrain V; Menu Y; Roche A
    AJR Am J Roentgenol; 2001 Jan; 176(1):187-92. PubMed ID: 11133564
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Radio-frequency thermal ablation with NaCl solution injection: effect of electrical conductivity on tissue heating and coagulation-phantom and porcine liver study.
    Goldberg SN; Ahmed M; Gazelle GS; Kruskal JB; Huertas JC; Halpern EF; Oliver BS; Lenkinski RE
    Radiology; 2001 Apr; 219(1):157-65. PubMed ID: 11274551
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.