These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

508 related articles for article (PubMed ID: 9809934)

  • 1. Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators.
    Marwick TH; Brunken R; Meland N; Brochet E; Baer FM; Binder T; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Pierard L; Vanoverschelde JL; van der Wouw P; Lindvall K
    J Am Coll Cardiol; 1998 Nov; 32(5):1260-9. PubMed ID: 9809934
    [TBL] [Abstract][Full Text] [Related]  

  • 2. NC100100, a new echo contrast agent for the assessment of myocardial perfusion--safety and comparison with technetium-99m sestamibi single-photon emission computed tomography in a randomized multicenter study.
    Binder T; Assayag P; Baer F; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Piérard L; Steg G; Vanoverschelde JL; Van der Wouw P; Meland N; Marelli C; Lindvall K
    Clin Cardiol; 1999 Apr; 22(4):273-82. PubMed ID: 10198737
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of color coding and subtraction on the accuracy of contrast echocardiography.
    Pasquet A; Greenberg N; Brunken R; Thomas JD; Marwick TH
    Int J Cardiol; 1999 Aug; 70(3):223-31. PubMed ID: 10501335
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of myocardial contrast echocardiography with NC100100 and (99m)Tc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction.
    Jucquois I; Nihoyannopoulos P; D'Hondt AM; Roelants V; Robert A; Melin JA; Glass D; Vanoverschelde JL
    Heart; 2000 May; 83(5):518-24. PubMed ID: 10768900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of resting perfusion defects in patients with acute myocardial infarction: comparison of myocardial contrast echocardiography, combined first-pass/delayed contrast-enhanced magnetic resonance imaging and 99mTC-sestamibi SPECT.
    Lombardo A; Rizzello V; Galiuto L; Natale L; Giordano A; Rebuzzi A; Loperfido F; Crea F; Maseri A
    Int J Cardiovasc Imaging; 2006; 22(3-4):417-28. PubMed ID: 16496094
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detecting myocardial salvage after primary PTCA: early myocardial contrast echocardiography versus delayed sestamibi perfusion imaging.
    Sciagrà R; Bolognese L; Rovai D; Sestini S; Santoro GM; Cerisano G; Marini C; Buonamici P; Antoniucci D; Fazzini PF
    J Nucl Med; 1999 Mar; 40(3):363-70. PubMed ID: 10086696
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Myocardial contrast echocardiography in human beings: correlation of resting perfusion defects to sestamibi single photon emission computed tomography.
    Meza MF; Mobarek S; Sonnemaker R; Shuler S; Ramee SR; Collins TJ; White CJ; Aristizabal D; Murgo JP; Cheirif J
    Am Heart J; 1996 Sep; 132(3):528-35. PubMed ID: 8800021
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography.
    Abdelmoneim SS; Bernier M; Dhoble A; Moir S; Hagen ME; Ness SA; Pellikka PA; Abdel-Kader SS; Mulvagh SL
    Heart Vessels; 2010 Mar; 25(2):121-30. PubMed ID: 20339973
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of myocardial perfusion in patients with coronary artery disease. Comparison of myocardial contrast echocardiography and 99mTc MIBI single photon emission computed tomography.
    Olszowska M; Kostkiewicz M; Tracz W; Przewlocki T
    Int J Cardiol; 2003 Jul; 90(1):49-55. PubMed ID: 12821219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The value of myocardial contrast echocardiography compared with SPECT in detecting myocardial perfusion abnormalities in patients with anterior acute myocardial infarction.
    Olszowska M; Tracz W; Przewłocki T; Kostkiewicz M; Podolec P; Zalewski J; Zmudka K
    Kardiol Pol; 2004 Jan; 60(1):27-38. PubMed ID: 15004629
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of myocardial blood flow velocity reserve with myocardial contrast echocardiography in patients with suspected coronary artery disease: comparison with quantitative gated Technetium 99m sestamibi single photon emission computed tomography.
    Dawson D; Rinkevich D; Belcik T; Jayaweera AR; Rafter P; Kaul S; Wei K
    J Am Soc Echocardiogr; 2003 Nov; 16(11):1171-7. PubMed ID: 14608289
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion, postexercise regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy.
    Chua T; Kiat H; Germano G; Maurer G; van Train K; Friedman J; Berman D
    J Am Coll Cardiol; 1994 Apr; 23(5):1107-14. PubMed ID: 8144776
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 Multicenter Phase 2 Trial results).
    Wei K; Crouse L; Weiss J; Villanueva F; Schiller NB; Naqvi TZ; Siegel R; Monaghan M; Goldman J; Aggarwal P; Feigenbaum H; DeMaria A
    Am J Cardiol; 2003 Jun; 91(11):1293-8. PubMed ID: 12767419
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation between myocardial perfusion abnormalities detected with intermittent imaging using intravenous perfluorocarbon microbubbles and radioisotope imaging during high-dose dipyridamole stress echo.
    Ronderos RE; Boskis M; Chung N; Corneli DB; Escudero EM; Ha JW; Charlante C; Rim SJ; Portis M; Fabris N; Camilletti J; Mele AA; Otero F; Porter TR
    Clin Cardiol; 2002 Mar; 25(3):103-11. PubMed ID: 11890368
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of infarcted myocardium with real time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single photon emission computed tomography.
    Tousek P; Orban M; Martinoff S; Firschke C
    Heart; 2005 Dec; 91(12):1568-72. PubMed ID: 15774606
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice. Comparison with wall motion and technetium--99m sestamibi single--photon emission computed tomography.
    Branco L
    Rev Port Cardiol; 1999 Apr; 18(4):415-6. PubMed ID: 10371850
    [No Abstract]   [Full Text] [Related]  

  • 17. Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography.
    Lipiec P; Wejner-Mik P; Krzemińska-Pakuła M; Kuśmierek J; Płachcińska A; Szumiński R; Peruga JZ; Kasprzak JD
    J Am Soc Echocardiogr; 2008 Aug; 21(8):941-7. PubMed ID: 18385014
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparison of myocardial contrast echocardiography and 99mTc MIBI single photon emission computed tomography in the assessment of myocardial perfusion in patients with acute myocardial infarction].
    Olszowska M; Tracz W; Kostkiewicz M; Hlawaty M; Podolec P; Przewłocki T
    Pol Merkur Lekarski; 2006 Mar; 20(117):282-4. PubMed ID: 16780255
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Combined analysis of resting regional wall thickening and stress perfusion with electrocardiographic-gated technetium 99m-labeled sestamibi single-photon emission computed tomography: prediction of stress defect reversibility.
    Snapper HJ; Shea NL; Konstam MA; Oates E; Udelson JE
    J Nucl Cardiol; 1997; 4(1 Pt 1):3-10. PubMed ID: 9138837
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection of coronary artery disease using real-time myocardial contrast echocardiography: a comparison with dual-isotope resting thallium-201/stress technectium-99m sestamibi single-photon emission computed tomography.
    Lin SL; Chiou KR; Huang WC; Peng NJ; Tsay DG; Liu CP
    Heart Vessels; 2006 Jul; 21(4):226-35. PubMed ID: 16865298
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.