These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 9815872)
1. Endocardial activation mapping of ventricular tachycardia in patients : first application of a 32-site bipolar mapping electrode catheter. Schalij MJ; van Rugge FP; Siezenga M; van der Velde ET Circulation; 1998 Nov; 98(20):2168-79. PubMed ID: 9815872 [TBL] [Abstract][Full Text] [Related]
2. Percutaneous multielectrode endocardial mapping during ventricular tachycardia in the swine model. Eldar M; Fitzpatrick AP; Ohad D; Smith MF; Hsu S; Whayne JG; Vered Z; Rotstein Z; Kordis T; Swanson DK; Chin M; Scheinman MM; Lesh MD; Greenspon AJ Circulation; 1996 Sep; 94(5):1125-30. PubMed ID: 8790055 [TBL] [Abstract][Full Text] [Related]
3. Multipolar endocardial mapping of the right heart using a basket catheter: acute and chronic animal studies. Triedman JK; Jenkins KJ; Colan SD; Van Praagh R; Lock JE; Walsh EP Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 1):51-9. PubMed ID: 9121971 [TBL] [Abstract][Full Text] [Related]
4. Endocardial mapping and ablation of tachycardia guided by noncontact balloon catheter mapping system. Zou J; Cao K; Chen M; Yang B; Zhu L; Li W; Yang R; Chen C; Shan Q Chin Med J (Engl); 2002 Jun; 115(6):909-13. PubMed ID: 12123564 [TBL] [Abstract][Full Text] [Related]
5. Orthogonal electrode catheter array for mapping of endocardial focal site of ventricular activation. Desai JM; Nyo H; Vera Z; Seibert JA; Vogelsang PJ Pacing Clin Electrophysiol; 1991 Apr; 14(4 Pt 1):557-76. PubMed ID: 1710061 [TBL] [Abstract][Full Text] [Related]
6. Catheter ablation of subepicardial ventricular tachycardia using electroanatomic mapping. Ouyang F; Bänsch D; Schaumann A; Ernst S; Linder C; Falk P; Hachiya H; Kuck KH; Antz M Herz; 2003 Nov; 28(7):591-7. PubMed ID: 14689119 [TBL] [Abstract][Full Text] [Related]
7. Mapping and ablation of ventricular tachycardia guided by virtual electrograms using a noncontact, computerized mapping system. Strickberger SA; Knight BP; Michaud GF; Pelosi F; Morady F J Am Coll Cardiol; 2000 Feb; 35(2):414-21. PubMed ID: 10676689 [TBL] [Abstract][Full Text] [Related]
8. New simplified technique for 3D mapping and ablation of right ventricular outflow tract tachycardia. Saleem MA; Burkett S; Passman R; Dibs S; Engelstein ED; Kadish AH; Goldberger JJ Pacing Clin Electrophysiol; 2005 May; 28(5):397-403. PubMed ID: 15869671 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of a novel high-resolution mapping system for catheter ablation of ventricular arrhythmias. Viswanathan K; Mantziari L; Butcher C; Hodkinson E; Lim E; Khan H; Panikker S; Haldar S; Jarman JW; Jones DG; Hussain W; Foran JP; Markides V; Wong T Heart Rhythm; 2017 Feb; 14(2):176-183. PubMed ID: 27867071 [TBL] [Abstract][Full Text] [Related]
10. Clinical application of an integrated 3-phase mapping technique for localization of the site of origin of idiopathic ventricular tachycardia. Peeters HA; SippensGroenewegen A; Wever EF; Ramanna H; Linnenbank AC; Potse M; Grimbergen CA; van Hemel NM; Hauer RN; Robles de Medina EO Circulation; 1999 Mar; 99(10):1300-11. PubMed ID: 10077513 [TBL] [Abstract][Full Text] [Related]
11. High-density substrate-guided ventricular tachycardia ablation: role of activation mapping in an attempt to improve procedural effectiveness. Carbucicchio C; Ahmad Raja N; Di Biase L; Volpe V; Dello Russo A; Trivedi C; Bartoletti S; Zucchetti M; Casella M; Russo E; Santangeli P; Moltrasio M; Tundo F; Fassini G; Natale A; Tondo C Heart Rhythm; 2013 Dec; 10(12):1850-8. PubMed ID: 24055940 [TBL] [Abstract][Full Text] [Related]
12. Ultra high-density multipolar mapping with double ventricular access: a novel technique for ablation of ventricular tachycardia. Tung R; Nakahara S; Maccabelli G; Buch E; Wiener I; Boyle NG; Carbucicchio C; Bella PD; Shivkumar K J Cardiovasc Electrophysiol; 2011 Jan; 22(1):49-56. PubMed ID: 20653813 [TBL] [Abstract][Full Text] [Related]
13. Transcutaneous multielectrode basket catheter for endocardial mapping and ablation of ventricular tachycardia in the pig. Eldar M; Ohad DG; Goldberger JJ; Rotstein Z; Hsu S; Swanson DK; Greenspon AJ Circulation; 1997 Oct; 96(7):2430-7. PubMed ID: 9337220 [TBL] [Abstract][Full Text] [Related]
14. Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia. Aryana A; d'Avila A; Heist EK; Mela T; Singh JP; Ruskin JN; Reddy VY Circulation; 2007 Mar; 115(10):1191-200. PubMed ID: 17296855 [TBL] [Abstract][Full Text] [Related]
15. Catheter ablation of haemodynamically unstable or non-sustained ventricular tachycardia. Wu S; Kerwin WF; Peter CT; Gang ES; Ma H Acta Cardiol; 2007 Apr; 62(2):163-9. PubMed ID: 17536605 [TBL] [Abstract][Full Text] [Related]
16. Localization of the site of origin of postinfarction ventricular tachycardia by endocardial pace mapping. Body surface mapping compared with the 12-lead electrocardiogram. SippensGroenewegen A; Spekhorst H; van Hemel NM; Kingma JH; Hauer RN; de Bakker JM; Grimbergen CA; Janse MJ; Dunning AJ Circulation; 1993 Nov; 88(5 Pt 1):2290-306. PubMed ID: 8222124 [TBL] [Abstract][Full Text] [Related]
18. Utility of high density multielectrode mapping during ablation of scar-related ventricular tachycardia. Cano Ó; Plaza D; Saurí A; Osca J; Alonso P; Andrés A; Sancho-Tello MJ; Martínez-Dolz L J Cardiovasc Electrophysiol; 2017 Nov; 28(11):1306-1315. PubMed ID: 28744991 [TBL] [Abstract][Full Text] [Related]
19. [Noncontact endocardial mapping to guide ablation for hemodynamically unstable or nonsustained ventricular tachycardia]. Wu SH; Peter CT; Kerwin WF; Gang ES; Ma H Zhonghua Xin Xue Guan Bing Za Zhi; 2005 Nov; 33(11):998-1001. PubMed ID: 16563246 [TBL] [Abstract][Full Text] [Related]
20. Substrate mapping vs. tachycardia mapping using CARTO in patients with coronary artery disease and ventricular tachycardia: impact on outcome of catheter ablation. Volkmer M; Ouyang F; Deger F; Ernst S; Goya M; Bänsch D; Berodt K; Kuck KH; Antz M Europace; 2006 Nov; 8(11):968-76. PubMed ID: 17043071 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]