These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 9817259)

  • 1. Ergonomic evaluation of laparoscopic bowel suturing.
    Joice P; Hanna GB; Cuschieri A
    Am J Surg; 1998 Oct; 176(4):373-8. PubMed ID: 9817259
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.
    Sánchez-Margallo JA; Sánchez-Margallo FM
    Int J Comput Assist Radiol Surg; 2017 Dec; 12(12):2069-2077. PubMed ID: 28695479
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ergonomic principles of task alignment, visual display, and direction of execution of laparoscopic bowel suturing.
    Emam TA; Hanna G; Cuschieri A
    Surg Endosc; 2002 Feb; 16(2):267-71. PubMed ID: 11967676
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimal angle between instrument shaft and handle for laparoscopic bowel suturing.
    Ahmed S; Hanna GB; Cuschieri A
    Arch Surg; 2004 Jan; 139(1):89-92. PubMed ID: 14718283
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel technique for enterotomy closure in stapled laparoscopic intracorporeal anastomosis.
    di Saverio S; Birindelli A; Segalini E; Todero S; Botusan RA; Novello M; Kwan S; Biondi A
    Colorectal Dis; 2017 Oct; 19(10):O372-O376. PubMed ID: 28833963
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ideal manipulation angle and instrument length in hand-assisted laparoscopic surgery.
    Manasnayakorn S; Cuschieri A; Hanna GB
    Surg Endosc; 2008 Apr; 22(4):924-9. PubMed ID: 17704859
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combining of ETHOS Operating Ergonomic Platform, Three-dimensional Laparoscopic Camera, and Radius Surgical System Manipulators Improves Ergonomy in Urologic Laparoscopy: Comparison with Conventional Laparoscopy and da Vinci in a Pelvi Trainer.
    Tokas T; Gözen AS; Avgeris M; Tschada A; Fiedler M; Klein J; Rassweiler J
    Eur Urol Focus; 2017 Oct; 3(4-5):413-420. PubMed ID: 28753821
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Is a robotic system really better than the three-dimensional laparoscopic system in terms of suturing performance?: comparison among operators with different levels of experience.
    Park YS; Oo AM; Son SY; Shin DJ; Jung DH; Ahn SH; Park DJ; Kim HH
    Surg Endosc; 2016 Apr; 30(4):1485-90. PubMed ID: 26139502
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of Postural Ergonomics and Surgical Performance in Laparoendoscopic Single-Site Surgery Using a Handheld Robotic Device.
    Sánchez-Margallo FM; Sánchez-Margallo JA
    Surg Innov; 2018 Jun; 25(3):208-217. PubMed ID: 29482483
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Objective assessment based on motion-related metrics and technical performance in laparoscopic suturing.
    Sánchez-Margallo JA; Sánchez-Margallo FM; Oropesa I; Enciso S; Gómez EJ
    Int J Comput Assist Radiol Surg; 2017 Feb; 12(2):307-314. PubMed ID: 27423649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Precision in stitches: Radius Surgical System.
    Waseda M; Inaki N; Torres Bermudez JR; Manukyan G; Gacek IA; Schurr MO; Braun M; Buess GF
    Surg Endosc; 2007 Nov; 21(11):2056-62. PubMed ID: 17516121
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimal trocar placement for ergonomic intracorporeal sewing and knotting in laparoscopic hiatal surgery.
    Fingerhut A; Hanna GB; Veyrie N; Ferzli G; Millat B; Alexakis N; Leandros E
    Am J Surg; 2010 Oct; 200(4):519-28. PubMed ID: 20638045
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laparoscopic suturing: effect of instrument handling on suture strength.
    Bariol SV; Stewart GD; Tolley DA
    J Endourol; 2005 Nov; 19(9):1127-33. PubMed ID: 16283852
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of angle information system to facilitate the adjustment of needle-holding posture.
    Cao Y; Liu L; Miura S; Seki M; Kobayashi Y; Kawamura K; Fujie MG
    Int J Comput Assist Radiol Surg; 2017 Nov; 12(11):2003-2013. PubMed ID: 28555446
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A New Technique for Making the Aberdeen Knot in Laparoscopic Surgery.
    Miyazaki D; Ebihara Y; Hirano S
    J Laparoendosc Adv Surg Tech A; 2015 Jun; 25(6):499-502. PubMed ID: 25942558
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The surgeon's technical skill in suturing: an analysis of the actual suture tracks.
    Seki S; Iwamoto H; Osaki H; Komoto Y
    Surg Today; 1993; 23(9):800-6. PubMed ID: 8219613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A multi-degree-of-freedom needle driver with a short tip and small shaft for pediatric laparoscopic surgery: in vivo assessment of multi-directional suturing on the vertical plane of the liver in rabbits.
    Takazawa S; Ishimaru T; Fujii M; Harada K; Deie K; Fujishiro J; Sugita N; Mitsuishi M; Iwanaka T
    Surg Endosc; 2016 Aug; 30(8):3646-53. PubMed ID: 26511118
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of suturing in the vertical plane shows the efficacy of the multi-degree-of-freedom needle driver for neonatal laparoscopy.
    Takazawa S; Ishimaru T; Fujii M; Harada K; Sugita N; Mitsuishi M; Iwanaka T
    Pediatr Surg Int; 2013 Nov; 29(11):1177-82. PubMed ID: 23975019
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of orthodox versus off-optical axis endoscopic manipulations.
    Emam TA; Hanna G; Cuschieri A
    Surg Endosc; 2002 Mar; 16(3):401-5. PubMed ID: 11928016
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a needle driver with multiple degrees of freedom for neonatal laparoscopic surgery.
    Ishimaru T; Takazawa S; Uchida H; Kawashima H; Fujii M; Harada K; Sugita N; Mitsuishi M; Iwanaka T
    J Laparoendosc Adv Surg Tech A; 2013 Jul; 23(7):644-8. PubMed ID: 23755855
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.